CM-2021-067 - 3/12/2021
EXHIBIT "A" — Registered WR #: 3534881 Project Name: RRK: LTSTR CORR KENNEY FT SEG 4B, RRK - LS SUPPLEMENT TO THE AGREEMENT FOR STREET LIGHTING SERVICE BY AND BETWEEN ONCOR ELECTRIC DELIVERY COMPANY AND City of ROUND ROCK This Supplement ("Supplement") to the Agreement for Street Lighting Service dated ("Agreement"), is made and entered into this 2nd day of February, 2021, by Oncor Electric Delivery Company LLC, a Delaware limited liability company ("Company") and City of ROUND ROCK, ("Customer") both hereinafter referred to as the "Parties." In consideration of the mutual promises and undertakings herein set forth, the Parties hereby agree to amend the Agreement as follows: 1. The following Request for Street Lighting Service is hereby added to the Agreement: Request for Street Lighting Service dated February 2, 2021, attached hereto. 2. This Supplement shall become effective upon execution by the Parties. 3. This Supplement is subject to the terms and conditions of the Agreement. 4. If Customer has arranged for its designated agent or representative ("Customer's Agent") to pay to Company the contribution -in -aid -of -construction ("CIAC") referenced in the Agreement, then Customer's Agent shall execute this Amendment for the sole purpose of establishing such agent's agreement to pay such CIAC. 5. Except as otherwise provided herein, the Agreement shall continue in full force and effect in accordance with its terms. IN WITNESS HEREOF, the Parties have caused this Supplement to be executed in several counterparts, each of which shall be deemed an original but all shall constitute one and the same instrument. ONCOR ELECTRIC DELIVERY COMPANY .[� .cubit-Q�i i'�"L• �G�i Signature - Oncor Representative Lauren M. Simpson Printed Name — Oncor Representative Utilitiy Designer I Project Manager Title - Oncor Representative Ci of ROUND ROCK Si natu — Customer Representative Printte Nam/e— Customer Representative Title — Customer Representative 02/02/2021 3 - f o — ,;�-D Date Signed — Oncor Representative Date Signed — Customer Representative ---------_._^ _— — ———— ——————— — — — — —— * *For CIA puy poses only pursuant to Section (4) above * * Signature — Customer's Agent Title - Customer's Agent 88332.010002 DALLAS 49285v1 N,2 CZ(, 0(,`11 Printed Name — Customer's Agent Date Signed — Customer's Agent EXHIBIT "B" R. WR #: 3534881 PROJECT NAME: RRK: LTSTR CORR KENNEY FT SEG 4B, RRK - LS 1 `I REQUEST FOR STREET LIGHTING SERVICE Actions: A -Addition R-Removal RL-Relocation S-Service (Schedule D —Only) Order required from CR to Energize— Identifying ESID Action Yes/No Qty. Wattage Lamp Rate Luminaries I Location (Address, etc.) Premise (For New Type Schedule— Pole Type ESID Only) 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor A-15 3054690-09763260 ( ) HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (A-14) 3054644-09763262 HEAD 6893558 A I 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (A-13) 3054602-09763270 HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor ( A-12) 3054562-09763291 HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor A-I1) 3054522-09763312 HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (A-7L ) 3054449-09763363 HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (A-8L) 3054410-09763388 HEAD Comments: Requested illumination for the Kenney Fort Blvd Segment 4B Extension *Unmetered Facilities — Schedule A (Group 1 or 2), B (Group 1 or 2), C (Group 1 or 2), or D; R (Rectangular); P (Post -Top); H (Historical); CLOSEDIREMOVE ONLY I (Incandescent); W (Wall pack Mercury Vapor); Metered Facilities — Non -Company -Owned; or Metered Facilities — Company -Owned (closed to new installations) 1. Customer or Developer agrees to pay Company contribution -in -aid -of -construction in the amount of $0_00. 2. If Company is prevented from installing the requested facilities by any event of force majeure as defined in Section 5.2.4 of Company's Tariff for Retail Delivery Service, Company will return to Customer or Developer as appropriate, without interest, the entire amount of Customer or Developer's contribution - in -aid -of -construction payment, thereby terminating this supplement and Company's obligation to provide facilities requested herein. WR Number: 3534881 Date: 2/1/2021 EXHIBIT "B" ��[�p WR #: 3534881 PROJECT NAME: RRK: LTSTR CORR KENNEY FT SEG 4B, RRK - LS —j "° REQUEST FOR STREET LIGHTING SERVICE `✓ Actions: A -Addition R-Removal RL-Relocation .S-Service (Schedule D-Only) Order required from CR to Energize — Identifying ESID Yes/No Qh Wattage Lamp Rate Luminaries / Location (Address, etc.) Premise Action (For New g Type Schedule"" Pole Type (See Attached Sketch) ESID Only) A - COBRA 3743499-2782082 to (A-9) 3054367- 6893558 RL 2 265 LED LED, Cobra Head 40' Rnd, Steel, Anchor 09763396 HEAD A - COBRA 3743423-2781936 to (A-10) 3054306- 6893558 RL 2 265 LED LED, Cobra Head 40' Rnd, Steel, Anchor 09763421 HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (A-711) 3054433-09763335 HEAD 6893558 A 1 265 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor A-811 3054395-09763358 ( ) HEAD 2220743 A 2 ISO LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (B-1) 3053875-09763430 HEAD 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor B-2 3053919-09763430 ( ) HEAD 2220743 A 1 ISO LED A - COBRA LED, Cobra Head 40' Rod, Steel, Anchor B-3L 3053978-09763439 ( ) HEAD Comments: Requested illumination for the Kenney Fort Blvd Segment 4B Extension *Unmetered Facilities — Schedule A (Group 1 or 2), B (Group 1 or 2), C (Group 1 or 2), or D; R (Rectangular); P (Post -Top); H (Historical); CLOSED/REMOVE ONLY I (Incandescent); W (Wall pack Mercury Vapor); Metered Facilities — Non -Company -Owned; or Metered Facilities — Company -Owned (closed to new installations) 1. Customer or Developer agrees to pay Company contribution -in -aid -of -construction in the amount of $0_00. 2. If Company is prevented from installing the requested facilities by any event of force majeure as defined in Section 5.2.4 of Company's Tariff for Retail Delivery Service, Company will return to Customer or Developer as appropriate, without interest, the entire amount of Customer or Developer's contribution - in -aid -of -construction payment, thereby terminating this supplement and Company's obligation to provide facilities requested herein. WR Number: 3534881 Date: 2/1/2021 EXHIBIT "B" N�p RWR #: 3534881 PRaJECT NAME: RRK: LTSTR CORR KENNEY FT SEG 4B, RRK - LS R. REQUEST FOR STREET LIGHTING SERVICE Actions: A -Addition R-Removal RL-Relocation S-Service(ScheduleD - Only) Order required from CR to Energize— Identifying ESID Ves/No Qty Wattage Lamp Rate Luminaries! Location (Address, etc.) Premise Action (Far New Type Schedule— Pole Type ( See Attached Sketch) ESID Only) 2220743 A 1 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (B-4L) 3054020-09763438 HEAD 2220743 A 1 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor B-5L 3054066-09763438 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor B-6 3054110-09763430 ( ) HEAD 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor B-7 3054158-09763431 ( ) HEAD 2220743 A 2 ISD LED A - COBRA LED, Cobra Head 40' Rod, Steel, Anchor B-8 3054201-09763431 ( ) HEAD 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rod, Steel, Anchor B-10 3054245-09763430 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor C-1 3053829-09763430 ( ) HEAD Comments: *Unmetered Facilities — Schedule A (Group 1 or 2), B (Group 1 or 2), C (Group 1 or 2), or D; R (Rectangular); P (Post -Top); H (Historical); CLOSED/REMOVE ONLY I (Incandescent); W (Wall pack Mercury Vapor); Metered Facilities— Non -Company -Owned; or Metered Facilities— Company -Owned (closed to new installations) 1. Customer or Developer agrees to pay Company contribution -in -aid -of -construction in the amount of $0_00. 2. If Company is prevented from installing the requested facilities by any event of force majeure as defined in Section 5.2.4 of Company's Tariff for Retail Delivery Service, Company will return to Customer or Developer as appropriate, without interest, the entire amount of Customer or Developer's contribution - in -aid -of -construction payment, thereby terminating this supplement and Company's obligation to provide facilities requested herein. WR Number: 3534881 Date: 2/1/2021 EXHIBIT "B" p WR #: 3534881 PROJECT NAME: RRK: LTSTR CORR KENNEY FT SEG 4B, RRK - LS C5 "' REQUEST FOR STREET LIGHTING SERVICE Actions: A -Addition R-Removal RL-Relocation S-Service (Schedule D —Only) Order required from CR to Energize— Identifying ESID Yes/No Qty Wattage Lamp Rate Luminaries / Location (Address, etc.) Premise Action (For New Type Schedule— Pole Type (See Attached Sketch) ESID Only) 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor C-2 3053787-09763430 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (C-3) 3053740-09763430 HEAD 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (C-4) 3053696-09763432 HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (C-5) 3053650-09763433 HEAD 2220743 A 2 180 LED A -COBRA LED, Cobra Head 40' Rnd, Steel, Anchor C-6 3053606-09763435 ( ) HEAD 2220743 A l 180 LED A -COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-2L 3053091-09763670 ( ) HEAD 2220743 A 1 180 LED A -COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-1L 3053068-09763713 ( 1 HEAD Comments: Requested illumination for the Kenney Fort Blvd Segment 4B Extension *Unmetered Facilities — Schedule A (Group I or 2), B (Group 1 or 2), C (Group I or 2), or D; R (Rectangular); P (Post -Top); H (Historical); CLOSED/REMOVE ONLY I (Incandescent); W (Wall pack Mercury Vapor); Metered Facilities — Non -Company -Owned; or Metered Facilities — Company -Owned (closed to new installations) 1. Customer or Developer agrees to pay Company contribution -in -aid -of -construction in the amount of SO_00. 2. If Company is prevented from installing the requested facilities by any event of force majeure as defined in Section 5.2.4 of Company's Tariff for Retail Delivery Service, Company will return to Customer or Developer as appropriate, without interest, the entire amount of Customer or Developer's contribution - in -aid -of -construction payment, thereby terminating this supplement and Company's obligation to provide facilities requested herein. WR Number: 3534881 Date: 2/1/2021 EXHIBIT "B" (�p WR #: 3534881 PROJECT NAME: RRK: LTSTR CORR KENNEY FT SEG 4B, RRK - LS "7" "' REQUEST FOR STREET LIGHTING SERVICE Actions: A -Addition R-Removal RL-Relocation .S-Service (Schedule D -Only) Order required from CR to Energize — Identifying ESID Qty Watta e g Lamp Rate Luminaries 1 Location (Address, etc.) Premise Action (For New Type Schednle" Pole Type (See Attached Sketch) ESID Only) 2220743 A 1 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (D-3L) 3053115-09763625 HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (D-4) 3053140-09763577 HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-5 3053173-09763543 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-6 3053211-09763513 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor (D-7) 3053251-09763488 HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-8 3053295-09763468 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-9 3053337-09763454 t ) HEAD Comments: Requested illumination for the Kenney Fort Blvd Segment 4B Extension *Unmetered Facilities — Schedule A (Group I or 2), B (Group 1 or 2), C (Group 1 or 2), or D; R (Rectangular); P (Post -Top); H (Historical); CLOSED/REMOVE ONLY I (Incandescent); W (Wall pack Mercury Vapor); Metered Facilities — Non -Company -Owned; or Metered Facilities — Company -Owned (closed to new installations) 1. Customer or Developer agrees to pay Company contribution -in -aid -of -construction in the amount of $0_00. 2. If Company is prevented from installing the requested facilities by any event of force majeure as defined in Section 5.2.4 of Company's Tariff for Retail Delivery Service, Company will return to Customer or Developer as appropriate, without interest, the entire amount of Customer or Developer's contribution - in -aid -of -construction payment, thereby terminating this supplement and Company's obligation to provide facilities requested herein. WR Number: 3534881 Date: 2/1/2021 EXHIBIT "B" WR #: 3534881 PROJECT NAME: RRK: LTSTR CORR KENNEY FT SEG 413, RRK - LS C5NR• REQUEST FOR STREET LIGHTING SERVICE Actions: A -Addition R-Removal RL-Relocation .S-Service(Schedule D—Only) Order required from CR to Energize— Identifying Qty Wattage Lamp Rate Luminaries / Location (Address, etc.) Premise Action (For New Type Schedule' Pole Type See Attached Sketch () ESID Only) 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-10 3053382-09763445 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor D-1l 3053428-09763442 ( ) HEAD 2220743 A 2 180 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor C-10) 3053473-09763441 HEAD 2220743 A 2 ISO LED A - COBRA LED, Cobra Head 40' Rod, Steel, Anchor C-9 3053519-09763439 ( ) HEAD 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor C-8 3053563-09763437 ( ) HEAD 2220743 A 2 I80 LED A - COBRA LED, Cobra Head 40' Rnd, Steel, Anchor C-7 3053589-09763436 ( ) HEAD Comments: Requested illumination for the Kenney Fort Blvd Segment 4B Extension *Unmetered Facilities — Schedule A (Group 1 or 2), B (Group 1 or 2), C (Group 1 or 2), or D; R (Rectangular); P (Post -Top); H (Historical); CLOSED/REMOVE ONLY 1 (Incandescent); W (Wall pack Mercury Vapor); Metered Facilities— Non -Company -Owned; or Metered Facilities— Company -Owned (closed to new installations) 1. Customer or Developer agrees to pay Company contribution -in -aid -of -construction in the amount of $0_00. 2. If Company is prevented from installing the requested facilities by any event of force majeure as defined in Section 5.2.4 of Company's Tariff for Retail Delivery Service, Company will return to Customer or Developer as appropriate, without interest, the entire amount of Customer or Developer's contribution - in -aid -of -construction payment, thereby terminating this supplement and Company's obligation to provide facilities requested herein. WR Number: 3534881 Date: 2/1/2021 WR 3534881 Kenney Ft Blvd Seg 4B Illumination GC: Blake Chappell 254.760.8138 EC: John Bartleson 512.844.7628 Oncor PM Lauren Simpson 512.592.8334 Specifications for Electrical Underground Distribution Systems from Overhead Transformation, Secondary Service Accounts Specification DDS-4 OH Revision 10, March 2010 Only changes to the drawings I was sent are: •A-10 will be fed out of the B circuit and its location is shifted approximately 70ft to the south. •B-10 is shifted to the location of the future proposed light between B-8 and B-10. •C-1 thru C-6 will be connected to the B circuit. •The rest of the C circuit lights will be connected to the D circuit. 61651DB12FCA445 02/02/2021 1 10:41:11 AM CST ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS FOR ELECTRICAL UNDERGROUND DISTRIBUTION SYSTEMS FROM OVERHEAD TRANSFORMATION, SECONDARY SERVICE ACCOUNTS SPECIFICATION NUMBER DDS-4 OH TABLE OF CONTENTS SECTION 1- SCOPE Page I SECTION 2- REFERENCES Page 1 SECTION 3- DEFINITIONS Page I SECTION 4- GENERAL Page 1 SECTION 5- COMPANY RESPONSIBILITY Page 2 SECTION 6- CONTRACTOR RESPONSIBILITY Page 3 SECTION 7- ACCEPTANCE ATTACHMENTS: DDS-4 OH Detail Sheets 1- 14 Copyright 2010 Oncor Electric Delivery Company. All rights reserved Page 5 ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS FOR ELECTRICAL UNDERGROUND DISTRIBUTION SYSTEMS FROM OVERHEAD TRANSFORMATION, SECONDARY SERVICE ACCOUNTS SPECIFICATION NUMBER DDS-4 OH 1. SCOPE This document represents the minimum requirements and specifications for the installation of the electrical underground distribution systems fed from overhead transformation, serving Secondary Service Accounts, to be transferred to Oncor Electric Delivery Company ownership. 2. REFERENCES This specification shall be used in conjunction with the latest revision of the following publications. 2.1 The Electric Service Guidelines, Oncor Electric Delivery Company. 3. DEFINITIONS II Company: Oncor Electric Delivery Company and its designated representatives. 3.2 Contractor: Individual or firm installing electric underground service for Secondary Service Accounts. 3.3 Authority Having Jurisdiction: Generally an incorporated City or Town, but may be an agency of the County, State or Federal Government. 3.4 Point of Delivery: The point where Company's conductors are connected to premise's conductors, typically at the meter socket or service enclosure. 4. GENERAL 4.1 The latest edition of all applicable building and safety codes shall be followed in the installation of the electric 1 underground distribution system. Included, but not limited to, are the: 4.1.1 Local City Building and Fire Codes or any other applicable codes for a particular project location Copyright 2010 Oncor Electric Delivery Company. All rights reserved. 4. GENERAL (continued) 4.1.2 National Electrical Safety Code (NESC) 4.1.3 U.S. Occupational Safety and Health Act of 1970 (OSHA) 4.1.4 The American Concrete Institute (ACI) 4.1.5 The American Society for Testing and Materials (ASTM) 4.2 Upon receipt of all necessary information from the Contractor, a project sketch showing the route of the conduit line and other pertinent information will be furnished by the Company. 4.3 Prior to construction a meeting shall be held to discuss and coordinate construction and inspection. 4.4 The Company will require a signed easement at no cost or a filed plat incorporating Company easement requirements prior to the Company installing any electrical facilities. 4.5 Joint use ditch will be determined by the Company on an individual basis. 4.6 No electrical facilities shall be connected by the Company until after the final inspection is made and approval by the Authority Having Jurisdiction, as required by code, has been received. 5. COMPANY RESPONSIBILITY- The following shall be performed by, and the responsibility of, the Company: 5.1 The Company inspector is to inspect all conduit installations prior to the placing of backfill. 5.2 The Company inspector is responsible for all field changes and coordinates changes with the local Engineering office. 5.3 After approval of the installed conduit system by the Company inspector, and after the Contractor has signed all appropriate contracts, agreements, easements and has paid any required CIAC (contribution in aid of construction), the Company shall install service lat�ral cables up to the line side of the point of delivery. Copyright 2010 Oneor Electric Delivery Company. All rights reserved 5. COMPANY RESPONSIBILITY (continued) 5.4 Upon notification of final electrical inspection from the Authority Having Jurisdiction, the Company is to make final electrical connections at the point of delivery. 6. CONTRACTOR RESPONSIBILITY- The following shall be performed by, and the responsibility of, the Contractor: 6.1 The Contractor is to provide the Company a Site Plan, a Dimension Control Plan, an Elevation Plan, a Grading Plan and loading information. 6.2 The Contractor is to coordinate with the Company inspector for inspection of work prior to backfilling. 6.3 The Contractor is to provide personnel and vehicular access to the facility at all times. 6.4 The Contractor is to be held responsible for tine full direction and supervision of all work being performed by his employees, agents or contractors. The Contractor shall also be responsible for the area at all times prior to acceptance, particularly in the prevention of damage to the electrical distribution system by the activities of other trades and utilities. 6.5 All testing of concrete and backfill which is deemed necessary by the Company is to be performed by an independent testing laboratory at the Contractor's expense. 6.6 The Contractor is to replace at his expense any damaged equipment or work not in compliance with the requirements in these specifications, the project sketch, the DDS-4 OH Detail Sheets or as specified by the Company. 6.7 The Contractor is to furnish equipment and labor to lay out ditch, set grade, dig ditches, place conduit in ditch and place electrical connection boxes. Tine line shall run in as straight alignment as practicable. All conduit and bends shall be Schedule 40 PVC or Schedule 80 PVC and shall be electrical grade. All PVC conduit and bends shall be gray in color. 6.8 The Contractor may be required to furnish a spare conduit in the same ditch with service lateral conduit(s) and cap both ends at bends. I 6.9 The C tractor is to complete rough site grading, establish final Ilade and clear all obstru tions. Any change in final grade which requires the lowering or raising of electrical conductors or associated equipment is at the expense of the Contractor. 3 Copyright 2010 Oncor Electric Delivery Company. All rights reserved 6. CONTRACTOR RESPONSIBILITY (continued) 6.10 Minimum vertical crossing clearance of electrical conduits from other utilities' conduits is twelve (12) inches. 6.11 A lateral separation of five (5) feet from electrical conduits to other utilities' conduits is required on private property. 6.12 Backfilling of conduit trenches under paved areas and around conduit bends at riser poles is to be compacted to 95% of the density of surrounding undisturbed soil as per ASTM D 698. Stabilization must be uniform to bottom of ditch. An alternative method for backfilling around conduit bends consists of concrete backfill with bend. The method and location where used will be at the discretion of the Company. 6.13 Contractor is to pull a mandrel through each conduit to check and clear blockage and leave an approved pull tape in each conduit. Pull tape shall be furnished by the party providing conduit and shall be installed by Contractor. Mandrel shall be furnished by Contractor. Conduit shall be plugged at both ends. Reference DDS-3 UG Detail Sheet 8 for approved pull tapes. 6.14 Approved self-contained meter sockets or approved meter packs are to be provided and installed by the Contractor. Transocket meter bases and service enclosures (when required) are to be provided by the Company and installed by the Contractor. Reference the Electric Service Guidelines for approved self- contained meter sockets. Contact Company for approval of meter packs prior to letting bids and installing equipment. 6.15 For single occupant, C. T. metered Secondary Service accounts fed from overhead transformation, the Contractor is to provide and install the underground raceway to the riser pole. The Company shall provide, install, connect and maintain the service lateral conductor. 6.16 If socket type metering fed from overhead transformation is utilized, the Contractor is to mount the meter socket on the building with the location approved by the Company and provide and install the underground raceway to the riser pole. The Company shall provide, install, connect and maintain the service lateral conductor. 6.17 For multiple occupancy Secondary Service accounts fed from overhead transformation, the Contractor is to provide and install (1) the service lateral raceway from the service enclosure to the riser pole andj�2) the conductors and associated raceways from the service enclosure to the lit side of the meters. The Company shall provide, install, connect and maintain thi service lateral conductors to the line side of the service enclosure. Copyright 2010 Oncor Electric Delivery Company. All rights reserved 6. CONTRACTOR RESPONSIBILITY (continued) 6.18 For multiple occupancy Secondary Service accounts utilizing meter packs fed from overhead transformation, the Contractor is to provide and install the service lateral raceway from the meter pack enclosure to the riser pole. The Company shall provide, install, connect and maintain the service lateral conductors to the line side of the meter pack. 6.19 For Secondary Service Accounts fed from subsurface secondary/ service boxes or meter pedestals, the Contractor is to (1) provide and install the underground raceway and conductor to the load side of the secondary/ subsurface box or meter pedestal, and (2) provide and install the underground raceway between the secondary/ service box or meter pedestal and the riser pole. The service lateral conductors between the overhead transformer and the source side of the secondary/ service box or meter pedestal shall be supplied, installed, connected and maintained by the Company. The Contractor shall provide the connectors when required and the Company shall install these connectors on the Contractor's conductors and connect to the load side of the secondary/ service box. Reference the Electric Service Guidelines for approved compression type connectors. 6.20 The Contractor is to secure inspection and approval of premise's facilities by the Authority Having Jurisdiction prior to the connection of electrical facilities. 6.21 Meter sockets to multi -metered locations shall be clearly and permanently marked by the Contractor on the exterior and interior of the meter socket to indicate each location served. Engraved or stamped metal, weather resistant placards shall be used on the exterior of the meter socket and be permanently affixed. Permanent marker or other acceptable method shall be used to mark the location on the inside of the meter socket (at a location other than the cover) where it can be easily read. 7. ACCEPTANCE 7.1 The Company inspector shall meet with the Contractor and review the project prior to acceptance. Electrical facilities will be installed as approved by the Company inspector only after acceptance of the project. 5 Copyright 2010 Oncor Electric Delivery Company. All rights reserved DIRECTION OF OVERHEAD CONDUCTOR(S) r 1 I ALTERNATE POSITION Please leave an 8" TOP VIEW separation between pole and conduit for standoff WIRE 10' OF CONDUIT IN PLACE WHEN REQUIRED �� EXTEND BEND WITH 10' OF SCH.80 PVC f CONDUIT FOR ALIGNMENT OF BEND INSTALL NIPPLE WHEN REQUIRED TO EXTEND / BEND MIN. 8" ABOVE FINISHED GRADE r - FINISHED GRADE RISER POLE BY ?_--NOTE 4 24" IMIN. COMPANY "N PLAN VIEW NOTES 1. CONTACT COMPANY REPRESENTATIVE FOR (1) ROUTING OF CONDUIT LINE, (2) SIZE OF CODUIT, AND (3) INSTALLATIONS REQUIRING MORE THAN ONE RISER ON POLE. 2. LIMIT RACEWAY TO THREE 900 BENDS. IF MORE THAN THREE 90' BENDS ARE REQUIRED, CONTACT COMPANY REPRESENTATIVE. 3. DISTANCE BETWEEN 900 BENDS SHALL BE FIVE FEET MINIMUM. 4. REFERENCE DETAIL SHEET 10 FOR BEND RADIUS FOR ALL HORIZONTAL AND VERTICAL CONDUIT BENDS. NCR TERMINATION OF SECONDARY CONDUIT AT RISER POLE DDS-h OH DETAIL SHEET 1 OF 14 03 —10 FINISHED GRADE 24" MIN DOME TOP FOR 4" MIN SETTLING FINISHED GRADE TAMPED BACKFILL co 1 SECONDARY, SERVICE, OR STREET LIGHT CONDUIT 1 SECONDARY CONDUIT AND 1 STREET LIGHT CONDUIT VERTICALLY ARRANGED 6" MIN DOME TOP FOR SETTLING FINISHED GRADE LEGEND: © PRIMARY CABLE MIN N TAMPED BACKFILL 3" MIN. CONDUIT SECONDARY/SERVICE CABLE 12" MIN. DIRECT BURIED CO STREET LIGHT CABLE 1 SECONDARY CONDUIT AND 1 STREET LIGHT CONDUIT HORIZONTALLY ARRANGED NOTE: 1. CONSULT COMPANY REPRESENTATIVE FOR CONDUIT SIZE. 2. REFERENCE SHEETS 8 AND 9 FOR NOTES AND INSTRUCTIONS. 3. SEPARATION DIMENSIONS APPLY TO COMPANY CONDUITS OR CABLES ONLY. MAINTAIN 12" SEPARATION BETWEEN COMPANY CONDUITS OR CABLE AND FOREIGN CONDUITS OR CABLE. Nc R TRENCH REQUIREMENTS DDS-4 OH DETAIL SHEET 7 OF 14 03 - 10 1. TRENCH ALIGNMENT SHALL BE AS STRAIGHT AS CONDITIONS PERMIT. ANY DEVIATIONS FROM PLANNED ALIGNMENT SHALL HAVE PRIOR APPROVAL BY THE PROJECT ENGINEER/INSPECTOR, ALL TRENCH CUTS SHALL BE IN ACCORDANCE WITH EXISTING SAFETY REGULATIONS IN EFFECT. 2. TRENCH BOTTOM SHOULD BE UNDISTURBED, TAMPED, OR RELATIVELY SMOOTH EARTH. WHERE EXCAVATION IS IN ROCK, THE CONDUIT SHOULD BE LAID ON A LAYER OF CLEAN BACKFILL. 3. ALL BACKFILL SHOULD BE FREE OF DEBRIS OR OTHER MATERIAL THAT MAY DAMAGE THE CONDUIT SYSTEM OR CAUSE SETTLING. THE MATERIAL SHOULD FILL THE VOIDS AROUND THE CONDUIT TO PREVENT HOT SPOTS & SETTLING. 4. BACKFILL SHOULD BE ADEQUATELY COMPACTED. BACKFILL NOT UNDER PAVEMENT SHOULD BE COMPACTED TO THE DENSITY OF THE SURROUNDING UNDISTURBED SOIL. BACKFILL UNDER PAVEMENT SHOULD BE COMPACTED TO NOT LESS THAN 95% OF THE DENSITY OF UNDISTURBED SOIL AS DETERMINED BY ASTM D-698. 5. SEE SHEET 9 FOR INSTRUCTIONS FOR JOINING PVC CONDUIT. 6. EACH CONDUIT RUN SHALL BE CHECKED BY PULLING A MANDREL THROUGH THE ENTIRE LENGTH AT THE COMPLETION OF THE CIVIL INSTALLATION. 7. A PULL TAPE SHALL BE LEFT IN EACH CONDUIT. CONDUIT SHALL BE PLUGGED AT BOTH ENDS. APPROVED PULL TAPES CONDUIT SIZE MANUFACTURER CATALOG NO. TSN 1", 2", 3" & 4" ARNCO BL-WP25 321068 NEPTCO, INC. WP2500P 6" ARNCO BL-WP60 397616 NEPTCO, INC. RP6000N 8. CONTACT COMPANY REPRESENTATIVE FOR TRENCH DIMENSIONS FOR MORE THAN 2 CONDUITS IN SAME DITCH. INSTALLATION OF CONDUITv NC R NOTES AND INSTRUCTIONS DDS-4 OH DETAIL SHEET 8 OF 14 03 - 10 THE CHEMICALS USED IN SOLVENT WELDING OF CONDUIT ARE INTENDED TO PENETRATE THE SURFACE OF BOTH PIPE AND FITTING, WHICH AFTER CURING RESULT IN A COMPLETE FUSION AT THE JOINT, THE OVER -USE, OR THE UNDER -USE OF CHEMICALS RESULTS IN LEAKY JOINTS OR WEAKENED PIPE. A. CLEAN CONDUIT BY WIPING OFF ALL DUST, DIRT, AND MOISTURE FROM SURFACES TO BE CEMENTED, EITHER BY MECHANICAL OR CHEMICAL CLEANING. 1. MECHANICAL CLEANING - FINE ABRASIVE PAPER OR CLOTH (180 GRIT OR FINER) OR CLEAN OIL -FREE STEEL WOOL. 2. CHEMICAL CLEANING - CLEANER RECOMMENDED BY MANUFACTURER OR EQUIVALENT (METHYL ETHYL KETONE - MEK)• B. WITH A NON -SYNTHETIC BRISTLE BRUSH, APPLY AN EVEN COATING OF CEMENT TO THE OUTSIDE OF THE PIPE AND INSIDE THE SOCKET. MAKE SURE THAT THE AMOUNT OF CEMENT APPLIED TO THE CONDUIT IS EQUAL TO THE DEPTH OF THE SOCKET. BEFORE ASSEMBLY, IF SOME EVAPORATION OF SOLVENT FROM THE SURFACES TO BE JOINED IS NOTED, REAPPLY CEMENT, THEN ASSEMBLE. IF CEMENT BEING USED HAS AN APPRECIABLE CHANGE IN VISCOSITY OR SHOWS SIGNS OF JELLING, IT SHALL BE DISCARDED. IN NO CASE SHALL THINNER BE USED IN AN ATTEMPT TO RESTORE JELLED PVC CEMENT. THINNER MAY ONLY BE USED TO CHANGE THE VISCOSITY OF A MEDIUM BODIED CEMENT TO THAT OF A REGULAR BODIED CEMENT FOR APPLICATION ON PVC PIPE SMALLER THAN 2 V2 INCH DIAMETER. A MEDIUM BODIED CEMENT SHALL BE USED ON 2 V2 TO 6 INCH PVC PIPE. IN COLD WEATHER, USE A PRIMER TO SOFTEN THE JOINING SURFACES BEFORE APPLYING CEMENT. ALLOW LONGER CURE TIME. (SEE ITEM E). C. JOIN PIPE WITHIN 20 SECONDS OF APPLYING CEMENT, TURN THE PIPE V4 TURN TO ENSURE EVEN DISTRIBUTION OF CEMENT ON SURFACES TO BE BONDED. MAKE SURE THAT PIPE IS INSERTED TO THE FULL DEPTH OF THE SOCKET. D. CLEAN OFF ANY BEAD OR EXCESS CEMENT THAT APPEARS AT THE OUTER SHOULDER OF THE FITTING. EXCESS CEMENT ALLOWED TO REMAIN IN CONTACT WITH THE MATERIAL IS APT TO CAUSE WEAKENING OF THE MATERIAL AND SUBSEQUENT FAILURE. E. NEWLY ASSEMBLED JOINTS SHOULD BE HANDLED CAREFULLY UNTIL THE CEMENT HAS CURED THE RECOMMENDED SET PERIOD. SET PERIODS ARE RELATED TO THE AMBIENT TEMPERATURE AS FOLLOWS: 30 MIN. MINIMUM AT 600 TO 10&F 1 HR. MINIMUM AT 400 TO 60OF 2 HR. MINIMUM AT 200 TO 4O°F 4 HR. MINIMUM AT 00 TO 2&F INSTRUCTIONS FOR JOINING NC R PVC CONDUIT y DDS-4 OH DETAIL SHEET 9 OF 14 03 - 10 CONDUIT NOMINAL SIZE (IN.) MINIMUM BEND RADIUS (IN.) TYPE OF BEND MATERIAL FOR PULLS: 1 18 PVC 2 24 PVC 3 24 PVC 4 24 PVC 6 36 PVC NOTES: 1. SCH.80 PVC CONDUIT SHALL BE USED FOR ALL ABOVE GROUND INSTALLATIONS (POLE AND METER RISERS). SCH.40 MAY BE USED FOR ALL BELOW GROUND INSTALLATIONS. Ct CONDUIT BEND RIADIUS R AND MATERIAL DDS-4 OH DETAIL SHEET 10 OF 14 03- 10 CONDUIT OF CONDUIT BEND 3' 0 0 • o 0 O Q 0' L o o • o • o o• 0 O O p• o. 0 0� t"O • • 0 • o •. 0 • 0 O �• L Ij A • 0 0 • 0 0 O • O O oC °o 0 0 L 0 o� o 0 0 0 • • o• • o0 0 •o L" •� t1O 0 o • O ° • O o. 0 • • . p 11 Qo o 0 O o• o- 0 0 •c 3' APPROX GROUND LEVEL CONCRETE ENCASEMENT END OF CONDUIT BEND N CONCRETE ENCASEMENT BEND CONCRETE 1 INCH BEND 1.2 CUBIC FT. 2 INCH BEND 1.5 CUBIC FT. 3 INCH BEND 1.6 CUBIC FT. 4 INCH BEND 32 CUBIC FT. B INCH BEND &9 CUBIC FT. TABLE 1 NOTES: 1. CONTACT COMPANY INSPECTOR TO DETERMINE REQUIREMENT FOR BEND ENCASEMENT. 2. DO NOT BOND CONCRETE TO POLE WHEN ENCASING A POLE RISER BEND. cR CONCRETE ENCASED BENDS Nt000Qot DDS-4 OH DETAIL SHEET 11 OF 14 03 — 10 FINISHEDGRADE GAS MAIN COMMUNICATION 24" MIN 48" MIN PLUS GAS PIPE AND COMMUNICATION CONDUIT OUTSIDE DIAMETERS 12' MIN WATER, GAS STEAM OR 12' SEWER ELECTRIC 60' NOTES 1 & 2 12' NOTE 1 WATER, GAS STEAM OR SEWER NOTES: 1. VERTICAL CROSSING CLEARANCE FROM OTHER UTILITIES SHALL BE 12 INCHES. A 60 INCH LATERAL SEPARATION OF PARALLELING FOREIGN UTILITIES (EXCLUDING GAS AND COMMUNICATIONS) SHALL BE REQUIRED. AN EXCEPTION WOULD BE TO ALLOW GAS, TELEPHONE AND /OR CATV IN THE SAME DITCH AS COMPANY CONDUIT SYSTEM PROVIDING THE NESC REQUIREMENTS FOR CONDUff SEPARATION ARE MET OR EXCEEDED AND THE COMMUNICATIONS CIRCUITS ARE INSTALLED IN CONDUff. 2.IT IS UNDERSTOOD THAT ONLY 12 INCH SEPARATION IS REQUIRED ON PUBLIC RIGHTS -OF -WAY. PERSONNEL INVOLVED IN EXCAVATION ON PUBLIC RIGHTS -OF -WAY ARE FULLY AWARE OF THE HAZARDS INVOLVED, HOWEVER, EXCAVATION ON PRIVATE PROPERTY CAN BE DONE BY INDIVIDUALS WHO ARE NOT LIKELY TO BE FULLY AWARE OF THE HAZARDS. THEREFORE, THE 60 INCH LATERAL SEPARATION IS REQUIRED TO HELP PREVENT INJURY TO PERSONNEL DOING EXCAVATION ON PRIVATE PROPERTY. CLEARANCE REQUIREMENTS Nc R FROM FOREIGN UTILITIES ON PRIVATE PROPERTY DDS-4 OH DETAIL SHEET 12 OF 14 G*lm[17 213 - 330 08 - 09 Foundations are Precast and will be provided by Oncor 14" BOLT CIRCLE FINISHED TRENCH BOTTOM STREET LIGHT FOUNDATION 213 - 330 25', 30' & 40' SQUARE STEEL POLE 00 - 09 40' M.H. ROUND STEEL POLE NOTES: 1. CONCRETE TO BE MINIMUM d 3000 PSI AT 28 DAYS. (5 SACK( MAXIMUM AGGREGATE 3�4" TOP OF _ A FOUNDATION TO BE TROWELED TO A FLAT AND LEVEL SURFACE. AVOID EXCESSNE TROWELING. \ e CONCRETE TO SET A MINIMUM —�� OF 72 HOURS BEFORE POLE INSTALLATION. PROJECTION 3" PROJECTION 2. REBAR HOOPS ARE TIED BEGINNING AS REO'D SEE NOTE 3 3" BELOW TOP OF CONCRETE FORM AND ARE REPEATED AT APPROXIMATE 3•' 6„ 1' INTERVALS TO BOTTOM OF —� MAX FOUNDATION. SECTION "A -A " 3. 1" ANCHOR BOLTS TO BE USED WITH 25' & 30' POLE. 1 Y4" ANCHOR BOLTS TO BE USED WITH 40' POLE. USE TEMPLATE FURNISHED BY POLE MANUFACTURER FOR ALIGNING ANCHOR BOLTS, PROJECTION OF 3" ON 25' & 30' SQUARE AND 3 W' ON 40' SQUARE AND ROUND POLES. 4. CONCRETE FORM OF SONOTUBE TO EXTEND TO BOTTOM OF TRENCH OR i0" AS NEEDED. 5. PROVIDE MINIMUM 24" GROUND WIRE PIGTAIL OUT OF CONCRETE FOR CONNECTION TO POLE. 6. A MINIMUM OF 12' OF BARE #6 SO CU WIRE TO BE PLACED IN BOTTOM OF HOLE AND COVERED WITH 2" OF DIRT 7. IF SOIL HAS BEEN DISTURBED, EXTEND FOUNDATION BY DEPTH OF DISTURBED SOIL. B. FOR POLE FOUNDATIONS LARGER THAN 40' NOMINAL MOUNTING HEIGHT, CONTACT DISTRIBUTION STANDARDS. ITEM QTY DESCRIPTION TSWREF Cu MU 1 6 #3 REBAR,18" DIAMETER HOOP, 3" OVERLAP 314470 317821 2 4 #5 REBAR, STRAIGHT, 60" LONG 3 4 ANCHOR BOLT, GALV.1' FOR 25 & MY POLES SEE NOTE 3 318585 SLF2530 3 4 ANCHOR BOLT,1 Y4" GALV FOR 40' POLES SEE NOTE 3 318586 SLF40 4 AS RECM CONCRETE FOUNDATION TUBE, 24' DIAMETER 313841 5 AS REOD CONDUIT, PVC OR PEC (NOT IN FOUNDATION AUN) 6 .5 LB WIRE, #6 COPPER, SOLID 303244 7 1 GROUND, POLE BUTT WIRE COIL CONCRETE g AS REnD 1 FND, PRECAST 25' & 30' SQR. POLE,14" BC, I- BOLTS 398698 398700 SLFPSQ2530 1 FND, PRECAST W SQR, 40' RND POLE,14" BC,1.25" BOLTS SLFP40 APPROVED BY NC R Street Light Boxes are precast ill w and be provided and will Street Light Secondary 213 - 040 Connection Box 12 - 19 There will need to be a box at every foundation location -- this is the connection point for the light out of the circuit \ o 14 3/4" Top View With Cover Removed Dra Hole InSE 14 3/4" Insert for 3/8" - 16 x 1 1/2" Cross Section 1 Lifting Slot Non-skid Surface Cover 12 3/4" Notes : A. For use when conductor size and number of terminations warrant. B. H-10 (light vehicular traffic loading). C. Replacement cover TSN is 326507. Item Description TSN/Ref CU — -- — -- ------ --- -- i} Box, Secondary 12" x 12" x 12" 300306 SLSCB Copyright 2019 Oncor Electric Delivery Company. All rights reserved. C�cy Rd ROUND ROCK TEXAS City of Round Rock Agenda Item Summary Agenda Number: Title: Consider executing a Supplement to the Agreement for Street Lighting Service with Oncor Electric Delivery Company, LLC related to new streetlights for the Kenney Fort Boulevard Segment 4B Extension Project. Type: City Manager Item Governing Body: City Manager Approval Agenda Date: 3/12/2021 Dept Director: Gary Hudder, Transportation Director Cost: Indexes: Attachments: 20070_Oncor Streetlight Agreement 02092021 bc, 20070_Oncor Illumination Specs 02092021 bc Department: Transportation Department Text of Legislative File CM-2021-067 This is a Street Light Agreement between Oncor Electric Delivery Company LLC and the City of Round Rock for the installation of the street lights on the Portion of Kenney Fort 4B Arterial Roadway. Oncor will supply poles and heads with LED lights and install the system. There are no monies associated with this agreement. City of Round Rock Pagel of 1