Loading...
Z-99-02-25-12B3 - 2/25/1999 (2)THE STATE OF TEXAS COUNTY OF WILLIAMSON CITY OF ROUND ROCK I, JOANNE LAND, Assistant City Manager /City Secretary of the City of Round Rock, Texas, do hereby certify that I am the custodian of the public records maintained by the City and that the above and foregoing is a true and correct copy of Ordinance No. Z- 99- 02- 25 -12B3 which was passed and adopted by the City Council of the City of Round Rock, Texas, at a meeting held on the 25th day of February 1999 as recorded in the minutes of the City of Round Rock in Book 40 Pages 157 and 158. CERTIFIED by my hand and seal of the City of Round Rock, Texas on this 27th day of July 1999. 199951346 90 pe s NNE LAND, Assistant City Manager/ City Secretary ORDINANCE NO. 2 99 09945 5 - /g133 AN ORDINANCE AMENDING THE OFFICIAL ZONING MAP OF THE CITY OF ROUND ROCK, TEXAS ADOPTED IN SECTION 11.305(2), CODE OF ORDINANCES (1995 EDITION), CITY OF ROUND ROCK, TEXAS, AND MAKING THIS AMENDMENT A PART OF THE SAID OFFICIAL ZONING MAP, TO WIT: TO ZONE 58.142 ACRES OF LAND AND TO REZONE 54.65 ACRES OF LAND OUT OF THE J.M. HARRELL SURVEY, ABSTRACT 284, IN ROUND ROCK, WILLIAMSON COUNTY, TEXAS, FROM DISTRICT C -1 (GENERAL COMMERCIAL) TO PLANNED UNIT DEVELOPMENT (PUD) NO. 38. WHEREAS, an application has been made to the City Council of the City of Round Rock, Texas to amend the Official Zoning Map to zone 58.142 acres of land, and to rezone 54.65 acres of land out of the J.M. Harrell Survey, Abstract 284, in Round Rock, Williamson County, Texas, being more fully described in Exhibit "A ", attached hereto and incorporated herein, from District C -1 (General Commercial) to Planned Unit Development (PUD) No. 38, and WHEREAS, the City Council has submitted the requested change in the Official Zoning Map to the Planning and Zoning Commission for its recommendation and report, and WHEREAS, the Planning and Zoning Commission held a public hearing concerning the requested change on the 17th day of February, 1999, following lawful publication of the notice of said public hearing, and WHEREAS, after considering the public testimony received at such hearing, the Planning and Zoning Commission has recommended that the Official Zoning Map be amended so that the property described in Exhibit "A" be zoned as Planned Unit Development (PUD) No. 38, and a: 1NPDX S OnnVp,C W WHEREAS, on the 25th dAy of Pebruary, 1999, after proper notification, the City Council held a public hearing on the requested amendment, and WHEREAS, the City Council determines that the zoning provided for herein promotes the health, safety, morals and protects and preserves the general welfare of the community, and WHEREAS, each and every requirement set forth in Chapter 211, Sub - Chapter A., Texas Local Government Code, and Section 11.300, Code of Ordinances (1995 Edition), City of Round Rock, Texas concerning public notices, hearings, and other procedural matters has been fully complied with, Now Therefore BE IT ORDAINED BY THE COUNCIL OF THE CITY OF ROUND ROCK, TEXAS, THAT: I. That the Official Zoning Map adopted in Section 11.305(2), Code of Ordinances (1995 Edition), City of Round Rock, Texas, is hereby amended so that the zoning classification of the property described in Exhibit "A" is hereafter designated as Planned Unit Development (PUD) No. 38. II. A. All ordinances, parts of ordinances, or resolutions in conflict herewith are expressly repealed. B. The invalidity of any section or provision of this ordinance shall not invalidate other sections or provisions thereof. 2. C. The City Council hereby kinds and declares that written notice of the date, hour, place and subject of the meeting at which this Ordinance was adopted was posted and that such meeting was open to the public as required by law at all times during which this Ordinance and the subject matter hereof were discussed, considered and formally acted upon, all as required by the Open Meetings Act, Chapter 551, Texas Government Code, as amended, and the Act. Alternative 1. By motion duly made, seconded and passed with an affirmative vote of all the Council members present, the requirement for reading this ordinance on two separate days was dispensed with. READ, PASSED, and ADOPTED on first reading this 45 of , 1999. Alternative 2. READ and APPROVED on first reading this the day of , 1999. READ, APPROVED and ADOPTED on second reading this the day of , 1999. ATTEST: A2.PJ a Ct41 L LAND, City Secretary CHARLES CULPEPP'R, M•yor City of Round Rock, Texas 3. List of Exhibits 1. Exhibit A: Property Description page 5 2. Exhibit B: Agreement and Development Plan page 18 3. Exhibit C: Lienholder Consent page 26 4. Exhibit D: Permitted Uses and Limitations page 27 5. Exhibit E: Project Identification Sign Locations page 33 6. Exhibit F: Combination and Monument Sign Locations page 34 7. Exhibit G: Utility Schematic and Drainage Plan page 35 8. Exhibit H: Roadway Light Fixtures page 36 9. Exhibit L Permitted Outdoor Sales Area page 37 10. Exhibit J: Sidewalk Locations page 38 11. Exhibit K: Parking Lot and Walkway Light Fixtures page 39 12. Exhibit L: Traffic Impact Analysis page 41 F: 4nalbas \080000161pud'pud- oo-e.004 La Frontera East - PUD No. 38 Ordinance Page 4 -4- Tract I: Parcel A: A 40 acre tract of land being Lot 1, Block "A ", La Frontera Section I, a subdivision in the city of Round Rock, Williamson County, Texas, according to the map or plat thereof recorded in Cabinet Q, Slides 203, 204 and 205 of the Plat Records of Williamson County, Texas, being described by metes and bounds on Exhibit A -1 attached hereto. Tract II: A 58.142 acre tract of land more fully described on Exhibit A -3 attached hereto. La Frontera East - PUD No. 38 Property Description Page 1 of 2 EXHIBIT A PROPERTY DESCRIPTION OF 112.766 ACRES OF LAND Parcel B: A 14.625 acre tract of land more fully described on Exhibit A -2 attached hereto. -5- r+ m . p N D� �• t0 a e Ni sano Tongumo • 3.258 An. 0 .172 Ac. pro t 0386 SKETCH TO ACCOMPANY DESCRIPTION 3a i.r, 3 t Rou Rock M N Rid3ehill Inr..+ Chisholm Volley South CS- o ` 2 .128 —crest Sec. 10 Rub. te' Lot 1 81 A, RssuD. Chisholm Valley o a � _d South Section Fire Northrid Acre, Northridge Acres L imestone Ridge Apmis. Tom N o 9. 17 Ac . Tom E. Nelson 9.80 Ac. DATE: December, 1998 JOB No.: 352- 703 -51 BY: M. Nolen 1s SCALE: 1" = 1000' fi li .1108�9g F Tracl Sac. l I LI00 - Ac. Co. Lot IA.li Corners of Corners North Lot 1 81. A Amended Plat Corners North Baker— Aicklen de Associates, Inc. Engineers /Surveyors Fil name: M: \MARGIE \352703 \ PUD PI 1 date: 12/18/90 ° c ` U 40.000 Acre Tract Page lof 2 LA FRONTERA SECTION I DESCRIPTION FOR A 40.000 ACRE TRACT OF LAND SITUATED IN THE J. M. HARRELL SURVEY, ABSTRACT NO. 284, IN WILLIAMSON COUNTY, TEXAS, BEING ALL OF LA FRONTERA SECTION I, A SUBDIVISION RECORDED IN CABINET Q, SLIDES 203 -205 OF THE PLAT RECORDS OF SAID COUNTY, SAID 40.000 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING on an iron found on the southeasterly corner of said Lot 1, same being a point in the westerly right -of - -way of Interstate Highway No. 35 (right -of -way width varies), same being a point in the easterly boundary line of a 227.8382 acre tract as conveyed by instrument recorded as Document No. 9848753 of the Official Records of said County, said point also being a southeasterly comer and POINT OF BEGINNING hereof; THENCE with the southerly boundary line of said Lot 1, the following four (4) courses and distances: 1) S 86° 58' 29" W fora distance of 192.73 feet to an iron rod found on an angle point hereof; 2) S 86° 54' 05 W for a distance of 112.97 feet to an iron rod found on an angle point hereof; 3) S 14° 05' 19" E for a distance of 47.87 feet to an iron rod found on an angle point hereof; 4) S 86° 55' 00" W (Bearing Basis/Directional Control Line) for a distance of 1519.30 feet to an iron rod found on the southwesterly corner hereof; THENCE with the westerly boundary line of said Lot 1, N 15° 00' 21" E for a distance of 1244.48 feet to an iron rod found on the northwesterly corner of said Lot 1, said point being the northwesterly corner hereof; THENCE with the northerly boundary line of said Lot 1, La Frontera Section I, same being a northerly boundary line of said 227.8382 Acre Tract, also being in part with the southerly boundary line of Lot 1, Block A, Chisholm Valley South Section Five, a subdivision as recorded in Cabinet G, Slide 178 of said Plat Records, the following three (3) courses and distances: EXHIBIT A _ / Page / of 3 -7- 40.000 Acre Tract Page 2of 2 1) N 87° 45' 45" E fora distance of 122.11 feet to an angle point hereof; 2) N 02° 14' 15" W for a distance of 4.72 feet to an angle point hereof; 3) N 88° 02' 13" E for a distance of 1006.09 feet to an iron rod found on the northeasterly corner of said Lot 1, La Frontera Section I, same being the southeasterly corner of said Lot 1, Chisholm Valley South Section Five, same being a point in the westerly right -of -way line of said Interstate Highway No. 35, being the northeasterly comer hereof; THENCE with the westerly right -of -way line of said Interstate Highway No. 35, same being with the easterly boundary line of said Lot 1, La Frontera Section I, also being the easterly boundary line of said 227.8382 Acre Tract, the following three (3) courses and distances: 1. S 20° 33' 51" E for a distance of 720.67 feet to an angle point hereof; 2. S 18° 53' 51" E for a distance of 12.71 feet to a concrete monument found, being on angle point hereof; 3. S 14° 03' 46" E for a distance of 427.60 feet to the POINT OF BEGINNING hereof and containing 40.000 acres of land. Surveyed under the direct supervis' n of the undersigned: Cecil 3 Q!.. n Chisholm Regist Professional Land Surveyor No. 4295 BAKER - AICKLEN & ASSOCIATES, INC. 203 E. Main Street, Suite 201 Round Rock, Texas 78664 (512) 244-9620 Job No.: 352 - 703 - 23 File Name: MIMARGIE'3527031MB PUD - LAF1 EXHIBIT /9" Page a of 3 Dated -8- SKETCH TO ACCOMPANY DESCRIPTION n N ? Round Rock a 4 a' w o Nt Rld Inv. Chisholm Volley 10 South ev e- ' 3 - 2.I Z8 Aorea Sec. Resu e sholm Valley Ch Lot I ° m i BI. A, Resub. n o 01' -� /South Section Flve p ° 1. anon Cam. Tom E. Nelson Lel I BI. A Amended A 9.80 Ac. Corners North Holding Co. FaraelsSs Maur. 11.108 Ae. DATE: December, 1998 JOB No.: 352 - 703 -51 BY: M. Nolen Baker — Aicklen & Associates, Inc. Engineers /Surveyors File name: M: \MARGIE \352703 \PUO Plot darn: I /s4 /nn 14.625 Acre Tract Page 1 of 2 P.U.D. — 14.625 ACRES DESCRIPTION FOR A 14.625 ACRE TRACT OF LAND SITUATED IN THE J. M. HARRELL SURVEY, ABSTRACT NO. 284, IN WII LIAMSON COUNTY, TEXAS, BEING ALL OF A 14.625 ACRE TRACT CONVEYED TO D.D.R. DB DEVELOPMENT BY INSTRUMENT RECORDED AS DOCUMENT NO. 9844186 OF THE OFFICIAL RECORDS OF SAID COUNTY, SAID 14.625 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING on an iron rod found on the southeasterly corner of said 14.625 Acre Tract, same being a point in the northerly right-of-way Tine of F. M. Highway No. 1325 (120' right -of -way width), said point being the southeasterly corner and POINT OF BEGINNING hereof; THENCE with the southerly boundary line of said 14.625 Acre Tract, same being the northerly right -of -way line of said F. M. Highway No. 1325, S 86° 56' 50" W for a distance of 403.67 feet to an iron rod found on the southwesterly comer of said 14.625 Acre Tract, same being a southeasterly comer of a 227.8382 acre tract as conveyed by instrument recorded as Document No. 9848753, same being the southwesterly comer hereof, THENCE departing said F. M. Highway No. 1325, with the westerly boundary line of said 14.625 Acre Tract, same with the easterly boundary line of said 227.8382 Acre Tract, N 14° 05' 56" W for a distance of 1120.51 feet to an iron rod found on the northwesterly comer of said 14.625 Acre Tract, same being an angle point of said 227.8382 Acre Tract, same being the northwesterly comer hereof, THENCE with the northerly boundary line of said 14.625 Acre Tract, same being a southerly boundary line of 227.8382 Acre Tract, N 86° 55' 10" E (Bearing Basis/Directional Control Line) for a distance of 709.06 feet to an iron rod found on the northeasterly comer of said 14.625 Acre Tract, same being the northwesterly corner of Lot 1, Town & Country Mall Subdivision, a subdivision as recorded in Cabinet L, Slide 57, of the Plat Records of said County, same being the northeasterly corner hereof; THENCE with the westerly boundary line of said Lot 1, Town & Country Mall Subdivision, same being with an easterly boundary line of said 14.625 Acre Tract, S 03' 04' 58" E for a distance of 824.88 feet to an iron rod found on an angle point of said 14.625 Acre Tract, same being the southwesterly comer of said Lot 1, Town & Country Mall Subdivision, same being an angle point hereof; EXHIBIT A L Page / of 3 -10- 14.625 Acre Tract Page 2 of 2 THENCE with a southerly boundary line of said 14.625 Acre Tract, S 86° 51' 56" W for a distance of 91.29 feet to an iron rod found on an angle point of said 14.625 Acre Tract, same being an angle point hereof; THENCE with an easterly boundary line of said 14.625 Acre Tract, S 03° 05' 06" E for a distance of 275.08 feet to the POINT OF BEGINNING hereof and containing 14.625 acres of land. Surveyed under the direct supervision of the undersigned: Cecil Ja on Chisholm Registe . Professional Land Surveyor No. 4295 BAKER- AICKLEN & ASSOCIATES, INC. 203 E. Main Street, Suite 201 Round Rock, Texas 78664 (512) 244-9620 Job No.: 352-703-23 File Name: M :IMARGIE3527031MB- PUD- CAPPS.doc EXHIBIT /9 Page 2 of 3 Dated 2 -44 " 41- n S t O Nisano tonguma %.258 Ac. a .172 0 11 pDop d a tU a al h a SKETCH TO ACCOMPANY DESCRIPTION n xN' Rou Rock m , p "s . Chisholm Volley Soulh 0 5 5 �� g Na n� 2 . 1 0 Acres Inv. t 2.1 0 A m Sec. 10 Resub. t etg Lot L 81 A, limb. Chisholm Sec Valley South Section Five Na Acres � No Acres ation Cern. Limes lone Ridge Apmis. Torn E. Nelson 9.317 Ac. POINT OF BEGINNING 14.625 ACRES DATE: December, 1998 JOB 110.: 352 - 703 -51 BY: M. Nolen e, SCALE: 1' = 1000' to eQ� Lot IA 01 A Amended Plat Corners Nor lh Lot 1 BI. A Amended Plot Corners North Holding Co. Formers Incur. 11.108 Ae. Tract Sec. 1 5. & Asso I n & Associates, Inc. Engineers /Surveyors Fil name: M: \MARGIE \352 \PUD PI 1 date: 1/29/99 Page 1 of 4 58.142 Acre Tract DESCRIPTION FOR A 58.142 ACRE TRACT OF LAND SITUATED IN THE J. M. HARRELL SURVEY, ABSTRACT NO. 284, SITUATED IN WIT J .AMSON COUNTY, TEXAS, BEING A PORTION OF A 227.8382 ACRE TRACT OF LAND CONVEYED TO 35/45 INVESTORS, L.P., A TEXAS PARTNERSHIP, BY INSTRUMENT RECORDED AS DOCUMENT NO. 9848753 OF THE OFFICAL RECORDS OF SAID COUNTY, SAID 58.142 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING on an iron rod found on a southeast corner of said 227.8382 acre tract, same being a point in the west right -of -way line of Interstate Highway No. 35 (right -of- way varies), same being the northeast corner of Lot 1, Block A, Resubdivision of Lot 1, Block A, Corners North a subdivision according to the plat thereof recorded in Cabinet J, Slide 118, of the Plat Records of said County, said point being the most easterly corner and POINT OF BEGINNING hereof, from which, a southeasterly corner of said J. M. Harrell Survey bears approximately S 40° 16' E a distance of 470 feet; THENCE departing the west right -of -way line of said Interstate Highway No. 35, in part with the north boundary line of said Lot 1, Block A, in part with the north boundary line of Lot 1, Town & Country Mall Subdivision, a subdivision as recorded in Cabinet L, Slide 57, of the Plat Records of said County, S 86° 55' 10" W (Bearing Basis/Directional Control Line) a distance of 884.72 feet, pass an iron rod found on the northwest comer of said Lot 1, Town & Country Mall Subdivision, same being the northeast comer of a 14.625 acre tract of land as described by instrument recorded as Document No. 9844186 of said Official Records, continue on said course with the north boundary line of said 14.625 acre tract for a total distance of 1593.78 feet to an iron rod found on the northwest corner of said 14.625 acre tract, same being an angle point hereof; THENCE with the west boundary line of said 14.625 acre tract, S 14° 05' 56" E for a distance of 1120.51 feet to an iron rod found on the southwest corner of said 14.625 acre tract, same being in the north right -of -way line of F. M. Highway No. 1325 (120' right - of-way width), being a southeasterly corner hereof; THENCE with the north right -of -way line of said F. M. Highway No. 1325, S 86° 56' 50" W for a distance of 545.22 feet to an iron rod set on the southeast comer of a 0.617 acre remnant tract of land as conveyed by instrument recorded in Volume 1628, EXHIBIT 4 Page 1 of .S -13- Page 2 of 4 58.142 Acre Tract Page 362, of the Official Records of said County, same being an angle point in the southerly boundary line hereof; THENCE departing the north right -of -way line of said F. M. Highway No. 1325 with the easterly, northerly, and westerly boundary line of said 0.617 acre tract the following three courses and distances: 1) N 13° 31' 33" W for a distance of 209.97 feet to an iron rod found on the northeast corner of said 0.617 acre tract, being an interior angle point hereof, 2) S 86° 52' 19" W for a distance of 129.90 feet to an iron rod found on the northwest comer of said 0.617 acre tract, being an interior angle point hereof; 3) S 13° 44' 29" E for a distance of 209.94 feet to an iron pipe found on a point in the north right -of -way line of said F. M. Highway No. 1325, same being the southwest corner of said 0.617 acre tract, being an angle point in the southerly boundary line hereof; THENCE with the north right -of -way line of said F. M. Highway No. 1325, S 86° 56' 50"W for a distance of 58.50 feet to a concrete monument found on a point of curvature hereof; THENCE with the arc of the curving right -of -way line of said F. M. Highway No. 1325 to the left, having a radius of 1014.88 feet, a central angle of 14° 09' 02", an arc length of 250.65 feet, and a chord which bears S 79° 52' 56" W for a distance of 250.01 feet to an iron rod set on the southwest corner hereof; THENCE departing the north right-of-way line of said F. M. Highway No. 1325 through the interior of said 227.8382 acre tract the following six courses and distances: 1) N 03° 03' 10" 'W for a distance of 356.15 feet to an iron rod set on a point of curvature hereof; 2) with the arc of a curve to the left, having a radius of 1040.00 feet, a central angle of 17° 27' 48 ", an arc length of 316.98 feet, and a chord which bears N 11° 47' 04" W for a distance of 315.76 feet to an iron rod set on a point of tangency hereof; 3) N 20° 30' 58" W for a distance of 1135.10 feet to an iron rod set on a point of . curvature hereof; ExHIBrr A- Page 2. of -14- Page 3 of 4 58.142 Acre Tract 4) with the arc of a curve to the left, having a radius of 1040.00 feet, a central angle of 16° 03' 48", an arc length of 291.57 feet, and a chord which bears N 28° 32' 52" W for a distance of 290.62 feet to an iron rod set on a point of tangency hereof; 5) N 36° 34' 46" W fora distance of 73.94 feet to an iron rod set on a curving arc hereof; 6) with the arc of a curve to the left, having a radius of 1000.00 feet, a central angle of 11° 11' 15", an arc length of 195.26 feet, and a chord which bears N 45° 32' 03" E for a distance of 194.95 feet to an iron rod set on a point of tangency hereof; 7) N 39° 56' 26" E for a distance of 109.62 feet to an iron rod set on a point of curvature hereof, 8) with the arc of a curve to the right, having a radius of 950.00 feet, a central angle of 14° 03' 57", an arc length of 233.22 feet, and a chord which bears N 46° 58' 24" E for a distance of 232.63 feet to an iron rod set on a point in the west boundary line of a 2.128 acre tract of land as described by instrument recorded as Document No. 9875537, of the Official Records of said County, same being in the northerly boundary line of said 227.8382 acre tract, same being an angle point in the northerly boundary line hereof, THENCE with the west boundary line of said 2.128 acre tract, same being the northerly boundary line of said 227.8382 acre tract, S 14° 20' 19" E for a distance of 12.21 feet to an iron rod found on the southwest corner of said 2.128 acre tract, being also an angle point in the northerly boundary line of said 227.8382 acre tract, being also an angle point in the northerly boundary line hereof, THENCE with the northerly boundary line of said 227.8382 acre tract of land, N 87° 45' 45" E for a distance of 1055.76 feet to an iron rod found on a point being the northwesterly corner of a 40.000 acre tract of land known as Lot 1, Block A, La Frontera, Section 1, a subdivision according to the plat thereof recorded in Plat Cabinet Q, Slides 203 -205 of said Plat Records, said point being a northeasterly comer hereof; THENCE with the west and south boundary line of said La Frontera Section 1, the following five courses and distances: 1) S 15° 00' 21" W for a distance of 1244.48 feet to an iron rod found on the southwest corner of said La Frontera Section 1, being an interior comer hereof; EXHIBIT 4 Page 3 of -15- Page 4of4 58.142 Acre Tract 2) N 86° 55' 00" E for a distance of 1519.30 feet to an iron rod found on an interior corner hereof; 3) N 14° 05' 19" W for a distance of 47.87 feet to an iron rod found on an angle point hereof; 4) N 86° 54' 05" E for a distance of 112.97 feet to an iron rod found on an angle point hereof; 5) N 86° 58' 29" E for a distance of 192.73 feet to an iron rod found on a point in the west right -of -way line of said Interstate Highway No. 35, said point being a northeasterly comer hereof; THENCE with the west right -of -way line of said Interstate Highway No. 3 5, S 14° 03' 46" E for a distance of 142.54 feet to the POINT OF BEGINNING hereof and containing 58.142 acres of land. Surveyed nder the direct supervision of the undersigned: xal '< . n Chisholm •i = • " Professional Land Surveyor No. 4295 • � � - A ICKLEN & ASSOCIATES, INC. 'n Street, Suite 201 Round Rock, Texas 78664 (512) 244-9620 Job No.: 352- 703 -23 File Name: M:IMARGIE13527031MB- LaF2.doc EXHIBIT Page 4 of S -16- Nisono Tangumo 3.258 Ac. I# :172 Ac. posed K e P• SKETCH TO ACCOMPANY DESCRIPTION 0 Cily of t) No tro Round Rock 4 . i•?.. 6. ,,•:: N Ridgehlll Inv.i N3 2.128 Acres np aG w � DK 35/45 Investors, L. P, 227.8382 Acres ' No Aiya gn 4 Norihrldge Acres Chisholm Valley South Sec.I0 Resub. ResuD. estete Lol Chlshhom Voll y V4 South S Five 1. Ime one R e Apmts. Tam E on Tom E. Nelson 9.80 Ac. DATE: December, 1998 JOB No.: 352- 703 -51 BY: M. Nolen 5� SCALE: 1' = 1000' to co co Lot IA, Amender Corners Lot BL A Amended Plot Corners North l Farmers Insur. H Co. Tract Sac. 1 11.108 Ac. ri POINT OF BEGINNING 58.142 ACRES A Plat forth ~) l Baker— Alcklen & Associates, Inc. Engineers /Surveyors File nom.: M: \MARGIE \352703 \PUD Plot date: 1/29/99 AGREEMENT AND DEVELOPMENT PLAN FOR LA FRONTERA EAST PLANNED UNIT DEVELOPMENT NO. 38 THE STATE OF TEXAS COUNTY OF WILLIAMSON THIS AGREEMENT AND DEVELOPMENT PLAN (this "Agreement ") is made and entered by and between the City of Round Rock, Texas, a Texas municipal corporation, having its offices at 221 East Main Street, Round Rock, Texas 78664 (hereinafter referred to as the "City"), and 35/45 Investors, L.P. and DDR DB Development Ventures LP, (hereinafter collectively referred to as the "Owner"). WHEREAS, the Owner has submitted a request to the City to zone approximately 112.766 acres of land as a Planned Unit Development ( "PUD "), said property being more particularly described in Exhibit "A" ( hereinafter referred to as the "Property "), and WHEREAS, pursuant to Chapter 11, Section 11.316(8), Code of Ordinances (1995 Edition), City of Round Rock, Texas, the Owner has submitted a development plan setting forth the development conditions and requirements within the PUD (the "Development Plan"), which Development Plan is contained in Section 11 of this Agreement; and WHEREAS, on FUR,2t /7 , 1999, the City's Planning and Zoning Commission recommended approval of the Owners application for a PUD. NOW THEREFORE BY THIS AGREEMENT WITNESSETH that, in consideration of the covenants and conditions set forth herein, the City and the Owner agree as follows: L GENERAL PROVISIONS 1. CONFORMITY WITH DEVELOPMENT PLAN All uses and development within the Property shall generally conform to the Development Plan set forth in Section II herein. La Frontera East - PUD No. 38 Agreement and Development Plan Page 1 EXHIBIT B -18- 2. CHANGES AND MODIFICATIONS No changes or modifications will be made to this Agreement or the Development Plan unless all provisions pertaining to changes or modifications as stated in Article III, Section 1 below are followed. 3. ZONING VIOLATION The Owner understands that any person, firm, corporation or other entity violating any conditions or terms of the Development Plan shall be subject to any and all penalties for the violation of any zoning ordinance as stated in Section 1.601, Code of Ordinances, (1995 Edition), City of Round Rock, Texas, as amended. 4. LIENHOLDER CONSENT There is no outstanding debt secured by the Property and no Iienholder of record. A Iienholder consent is not required. 5. MISCELLANEOUS PROVISIONS 5.1 Assignment Neither party may assign its rights and obligations under this Agreement without having first obtained the prior written consent of the other which consent shall not be unreasonably withheld. This section shall not prevent the Owner from conveying the Property or portions of the Property, together with all development rights and obligations contained in this Agreement. 5.2 Necessary Documents and Actions. 5.3 Severability. La Frontera East - PUD No. 38 Agreement and Development Plan Page 2 Each party agrees to execute and deliver all such other and further instruments and undertake such actions as are or may become necessary or convenient to effectuate the purposes and intent of this Agreement. In case any one or more provisions contained herein are deemed invalid, illegal or unenforceable in any respect, such invalidity, illegality or unenforceability shall not affect any other provisions hereof and in such event, this Agreement shall be construed as if such invalid, illegal or unenforceable provision had never been contained herein. -19- 5.4 Entire Agreement. This Agreement constitutes the entire agreement of the parties and supersedes any ' prior or contemporaneous oral or written understandings or representations of the parties respecting the subject matter hereof. 5.5 Applicable Law. This Agreement shall be construed under and in accordance with the laws of the State of Texas. 5.6 Venue. All obligations of the parties created hereunder are performable in Williamson County, Texas and venue for any action arising hereunder shall be in Williamson County. 5.7 No Third Party Beneficiaries. Nothing in this Agreement, express or implied, is intended to confer upon any person or entity, other than the parties hereto (and their respective successors and assigns) any rights, benefits or remedies under or by reason of this Agreement. 5.8 Duplicate Originals. This Agreement may be executed in duplicate originals, each of equal dignity. 5.9 Notices. Until changed by written notice thereof any notice required under this Agreement may be given to the respective parties by certified mail, postage prepaid or by hand delivery to the address of the other party shown below: OWNER 35/45 Investors, L.P. 808 West lO Street Austin, Texas 78701 Attn: William S. Smalling and La Frontera East - PUD No. 38 Agreement and Development Plan Page 3 DDR DB Development Ventures LP 5606 North McArthur Blvd., Suite 210 Irving, Texas 75038 Attn: David Berndt CITY OF ROUND ROCK City of Round Rock, Texas 221 East Main Street Round Rock, Texas 78664 Attn: Director of Planning -20- 5.10 Effective Date. This Agreement shall be effective from and after the date of due execution hereof by all parties. 5.11 Binding Effect. 1. DEFINITIONS 2. PROPERTY 3. PURPOSE La Frontera East - PUD No. 38 Agreement and Development Plan Page 4 This Agreement and the Development Plan binds and benefits the Owner and its successors and assigns. II. DEVELOPMENT PLAN Words and terms used herein shall have their usual force and meaning, or as defined in the Code of Ordinances (1995 Edition), City of Round Rock, Texas, hereinafter referred to as "the Code". This Development Plan ("Plan") covers approximately 112.766 acres of land, located within the city limits of Round Rock, Texas, and more particularly described in Exhibit "A ". The purpose of this Plan is to insure a Planned Unit Development ( "PUD ") that: (i) is equal to or superior to development that would occur under the standard ordinance requirements, (ii) is in harmony with the General Plan of the city of Round Rock, Texas, (iii) does not have an undue adverse affect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utilities or any other matters affecting the public health, safety and welfare, (iv) is adequately provisioned by essential public facilities and services, and (v) will be developed and maintained so as to not dominate, by scale or massing of structures, the immediate neighboring properties or interfere with their development or use in accordance with any existing zoning district. 4. APPLICABILITY OF CITY ORDINANCES 4.1 Zoning and Subdivision Ordinance. The Property shall be regulated for purposes of zoning and subdivision by this Plan. All aspects not specifically covered by this Plan shall be regulated by applicable sections of the Code. -21- 4.2 Other Ordinances. All other Ordinances within the Code shall apply to the Property, except as clearly modified by this Plan. 5. DEVELOPMENT AREAS The Property will be developed as a single development area. The total land area of 112.766 acres may be developed with buildings containing a combined maximum building area of no more than 1,228,022 square feet. 6. PERMITTED USES AND LIlVIITATIONS The Property will be used and developed in accordance with the requirements as set forth in this Agreement and, if not set forth herein, by applicable sections in the Code. Specific permitted uses of and limitations applicable to the Property are detailed on Exhibit "D" attached hereto and incorporated herein. 7. SIGNS 7.1 Project Identification Signs: Signs for the purpose of identifying the Property (the "Project Identification Signs ") as "La Frontera' (or other development name) may be installed and maintained by Owner on the Property at the locations designated on Exhibit "E" attached hereto and incorporated herein, provided no more than one Project Identification Sign is placed at each location. The Project Identification Signs may be no more than five feet (5') high, four feet (4') deep, and twelve feet (12) wide, unless otherwise approved by the City. The Project Identification Signs may not identify any specific occupants of the Property. The Project Identification Signs must be placed in accordance with the provisions of: (i) the setback and spacing requirements of Table 3.1403 of the Code, and (ii) the corner lot vision clearance requirements of Section 11.304(7) of the Code. No Project Identification Sign may be placed in any street or road right -of -way without a license agreement executed by the City. 7.2 Combination Signs: Signs for the purpose of identifying multiple occupants of the Property (the "Combination Signs ") may be installed and maintained by Owner on the Property at the locations designated on Exhibit "F' attached hereto and incorporated herein, provided no more than one Combination Sign is placed at each location. The Combination Signs may be no more than forty -five feet (45') high with no more than 405 square feet of sign face on each side, provided, however the Combination Sign to be installed in the area detailed as "Interior Location" on Exhibit "F" may be of a four sided tower design not more than sixty feet (60 ") high with no more than 240 square feet of sign face on each side. The Combination Signs must be placed in accordance with the provisions of: (i) the setback and spacing requirements of Table 3.1403 of the Code, and (ii) the corner lot vision clearance requirements of Section 11.304(7) of the Code. No Combination Sign may be placed in any street or road right -of -way without a license agreement executed by the City. La Frontera East - PUD No. 38 Agreement and Development Plan Page 5 -22- 7.3 Monument Signs: Monument signs for the purpose of identifying occupants of the Property may be located as designated on Exhibit "F ". The monument signs must be constructed in accordance with the specifications contained in the Code. 8. STORMWATER FILTRATION AND DETENTION. 8.1 Drainage: Plans for drainage facilities will be reviewed and approved by the City for each portion of the Property as each such portion of the Property is subdivided. A conceptual drainage plan is included in the Utility Schematic and Drainage Plan on file in the P &CD Department, a copy of which is attached hereto as Exhibit "G" and incorporated herein. Both the utility schematic and the drainage plan that are a part of Exhibit "G" are conceptual in nature and may be modified in the future. 8.2 Stormwater Facilities: Owner, at Owner's expense will construct all stormwater, sedimentation, filtration and/or detention ponds (the "Stormwater Ponds ") necessary to serve: (i) the public roads on the Property and (ii) the lots or other parcels of the Property. Owner may construct regional Stormwater Ponds serving multiple lots or road segments to fulfill Owner's obligations under this Section 8.2. Owner may delegate Owner's responsibility for construction and maintenance of the Stormwater Ponds to: (i) purchasers of lots or other parcels of the Property, or (ii) a separate entity created for such purpose. 9. ROADWAYS/TRAFFIC Development of the Property will be generally in accordance with the Traffic Impact Analysis attached hereto as Exhibit "L" and incorporated herein. Minor modifications may be made to the roadway plans by agreement between the Director of Public Works and Owner. 9.1 Road Construction: The following conditions concerning roads on the Property must be fulfilled before any building permit will be issued by the City for any lot that is a part of the Property: a. Road construction plans for Parker Avenue and Sundance Parkway east of Kouri Avenue (collectively, the "Roads ") have been approved by the City (the "Approved Plans "). b. Fiscal security for the construction of the Roads has been posted in accordance with the Code or construction of the Roads has been completed in accordance with the Approved Plans. 9.2 Light Fixtures: In connection with the construction of the roads, street light fixtures will be installed in accordance with the design shown on Exhibit "W' attached hereto and incorporated herein and conforming with the following specifications: a. The light fixture will be black or dark bronze in color and of a horizontal design with sharp cutoff edges. La Frontera East - PUD No. 38 Agreement and Development Plan Page 6 -23- b. The illumination source will be metal halide (or equivalent). c. The light fixture will be mounted on a metal pole. The pole will be the same color as the light fixture. 10. PHASED DEVELOPMENT The Owner has the option to develop the Property as a phased development. The Property may be platted into two or more Tots to accommodate phasing. 11. RESTRICTIONS The Property will be developed in accordance with any conditions, covenants or restrictions of record with the Williamson County Clerk. M. MISCELLANEOUS PROVISIONS 1. CHANGES TO DEVELOPMENT PLAN 1.1 Minor Changes. Minor changes to this Agreement or the Development Plan which do not substantially change this Agreement or the Development Plan may be approved administratively, if approved in writing, by the Director of Public Works, the Director of Planning and Community Development, and the City Attorney. 1.2 Major Changes. Major changes to this Agreement or the Development Plan must be resubmitted following the same procedure required by the original PUD application. 2. GENERAL PLAN AMENDED The Round Rock General Plan is hereby amended to reflect the provisions of this Agreement and Development Plan. La Frontera East - PUD No. 38 Agreement and Development Plan Page 7 CITY OF ' OUND ROCK, TEXAS Charles Culpe • p r, Mayor City of Round Rock, Texas Date: G9 -A , 1999 FA RMALBERS1080000I6 \PUD10RDRPL&007 La Frontera East - PUD No. 38 Agreement and Development Plan Page 8 35/45 INVESTORS, L.P. By: 35/45 Genpar, L.L.C. By: �� /., A 7 t am S. Sma Manager Date:# 31 , 199 DDR DB DEVELOPMENT VENTURES LP By: DDR DB Opportunity Sub, Inc. By: Name: Title: Date: , 199 -25- CITY OF ROUND ROCK, TEXAS 35/45 INVESTORS, L.P. By: 35/45 Genpar, L.L.C. By: Charles Culpepper, Mayor City of Round Rock, Texas By William S. Smalling, Manager Date: , 199_ DDR DB DEVELOPMENT VENTURES LP By: DDR DB Opportunity Sub, Inc. Date: ,199 F:\RMALBERS\08000016WUD ORD&PL-E.007 La Frontera East - PUD No. 38 Agreement and Development Plan Page 8 By u Name: 3 4! { . Title. ■l, a Prcc; Date: 1./i7 (O , 199 -25- La Frontera East - PUD No. 38 Lienitolder Consent Page 1 of 1 EXHIBIT C LIENHOLDER CONSENT NO LIENHOLDER NO LIENHOLDER CONSENT REQUIRED -26- Permitted Use* Building Height Limitation ** Building Setbacks from: Nester's Crossing Kouri Avenue Sundance Parkway Other Roads General Commercial (C -I) 45 feet 60 feet 25 feet 25 feet 25 feet Shopping Center 45 feet 60 feet 25 feet 25 feet 25 feet Restaurant * ** 45 feet 60 feet 25 feet 25 feet 25 feet Cinema 65 feet 60 feet 25 feet 25 feet 25 feet Office 45 feet 60 feet 25 feet 25 feet 25 feet PERMITTED USES AND LIMITATIONS APPLICABLE TO THE PROPERTY The permitted uses and limitations applicable to the Property are as follows: 1. Permitted Uses, Heights and Setbacks. ** * ** EXHIBIT D Permitted uses, building height limitations, building setbacks and landscaping setbacks are detailed in the chart below: Zoning designations noted in parentheses indicate all uses permissible under the Code for such designation as of the date of this Ordinance. Such uses may include, but are not limited to, other uses also listed in this chart. Limitations for any specific C -1 use listed in this chart will control over the general C -1 listing. Decorative architectural features may exceed the stated height limitation by 15 feet except that decorative architectural features in connection with a cinema may exceed the stated height limitation by 30 feet. Including bar and liquor sales. 2. Prohibited Uses. The following uses are prohibited on the Property: mini- warehouses, flea markets, sexually oriented businesses (as defused in the Code), amusement parks or carnivals, portable building sales except as incidental to other retail sales, recreational vehicle parks, wholesale nurseries, outdoor shooting ranges, pawn shops, heavy equipment sales, kennels (but not prohibiting pet shops and veterinary clinics with overnight facilities), vehicle sales and truck stops. 3. Outdoor Sales and Displays. Outdoor sales and displays are permitted in conjunction with the use of a building only in areas designated on the site plan filed with the City for such building. Outdoor sales and displays are further limited to the following areas: La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 1 -27- a. Sidewalks: on sidewalks adjacent to buildings, but limited to an area of no more than thirty percent (30%) of the sidewalk area that is located within twenty feet (20) from the building. In no event may the sidewalk sale and display area exceed five percent (5 %) of the interior floor area of the adjoining building. b. Dining: any outdoor cafe or outdoor dining area (including outdoor seating for a food court) that: (i) is located and operated as an integral part of the principal use, and (ii) does not comprise a separate business use or a separate business activity. Parking requirements contained in the Code will apply to all outdoor cafes and dining areas in the same manner that such requirements apply to enclosed buildings. c. Permitted Outdoor Sales Area: one area that is: (i) located as detailed in Exhibit "1" attached hereto and incorporated herein, but not more than 150 feet from the principal building that it serves, (ii) not greater than 10,000 square feet in size, and (iii) visually screened with a permanent landscape screen on all sides, except for the side facing the principal building that it serves. The landscape screen must be irrigated and of sufficient density to block views of the majority of the interior of the Permitted Outdoor Sales Area from ground level. The permitted outdoor sales area must be an area separate from (not a part of) any parking lots, however the permitted outdoor sales area may be adjacent to or surrounded by parking lots. The permitted outdoor sales area may not impede traffic circulation. 4. Buildings. a. Prohibited Materials: The following materials are prohibited on the exterior walls of all buildings and structures (this section does not apply to roofs): Sheet, corrugated, and unfinished Aluminum Asbestos Galvanized Steel Mirrored Glass (reflectivity of 20% or more) b. Building Elevations and Rooflines: To avoid the design of a continuous, unbroken wall facade and a continuous roofline (big box design), structures over 200 feet in length must be designed so as to stagger the front facades and rooflines to break up the visual expanse of the structures. 5. Sidewalks. All sidewalks will be located within the sidewalk zone as shown in the Traffic Impact Analysis attached hereto as Exhibit "L" and incorporated herein. One of the following is required along all public roads (except Farm to Market Road 1325): a Standard Sidewalks: Sidewalks at least 5 feet wide on both sides of the road as detailed on Exhibit "J" attached hereto and incorporated herein. La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 2 -28- b. Wide Sidewalk: A sidewalk at least 8 feet wide on one side of the road as detailed on Exhibit "J". - 6. Outdoor Storage, Service and Loading Areas. a. Screening Required: No outside storage or dock high loading area is permitted unless such area is visually screened from public view. b. Delivery Vehicles: All delivery and utility vehicles stored on -site must be inside a closed building or within a screened portion of the site. c. Service Areas: Service areas will be screened from adjacent tracts and all public rights -of -way. Methods of screening include walled entrances, evergreen landscaping, and depressed service areas. Screening walls must be constructed of the same materials as the main building. d. Loading Areas: All loading and service areas must be clearly signed. Loading spaces must be clearly denoted on the pavement and designed so as to not prohibit on -site vehicular circulation when occupied. Loading spaces will be located directly in front of a loading door. Loading areas must be designed to accommodate backing and maneuvering on -site, not from a public street. Regardless of orientation, loading doors may not be located closer than fifty feet (50') from a public or private right -of- way. e. Trash Storage: Refuse storage enclosures are required for all buildings. Enclosures must be of sufficient height to screen all refuse containers completely and must be provided with gates, so as to provide screening of views from adjacent lots and public rights -of -way, All enclosures must be constructed of permanent materials (concrete, masonry, wood, steel, etc.) which are compatible with the building it serves. Refuse storage areas must be designed to contain all refuse generated on -site between collections. (refer to figure 1) La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 3 SCREEN TRASH AREA FROM MIO•RISE VIEWS SERVICE COURT SCREEN WALL COMPATIBLE WITH EUILOING MATERIALS figure 1 -29- f. Street Level Mechanical Equipment: All ground- mounted service equipment (e.g., air conditioners, transformers, trash collection equipment) related to each building will be consolidated in an enclosed service area. Landscaping will be used to soften the visual appearance of the walls enclosing the service area. Service areas must be paved, curbed, and internally drained. g. 7. Exterior Lighting. La Frontons Fast - PUD No. 38 Permitted Uses and Limitations Page 4 Roof Mounted Mechanical Equipment: All roof mounted mechanical elements must be screened from view from the public right -of -way. Screening must be compatible with the building design. If roof decks with mechanical units are visible from any level of adjacent buildings, the mechanical units must be screened and painted to match the finished roof material. a. Minimal Spillover: All lighting must be installed to minimize light spillover onto adjacent properties. b. Parking Lot Fixtures: All light fixtures will be of a horizontal design with sharp cutoff edges. The fixture will be a rectangular box unit or a round puck -like unit (similar to Kim Lighting 's Curvilinear Cutoff series) with a minimum diameter of 17" (width) and maximum diameter of 29" as detailed on Exhibit "K". The fixture will be made of spun aluminum or similar quality material with sidewalls free of welds or fasteners and will have an illumination source of mercury vapor or metal halide. All fixtures and Tight standards will have a black or dark bronze powder coated finish. Fixture glass must be white or clear. Light standards will be metal poles 40 feet high. (refer to figure 2) c. Open Space, Walkway and Passenger Drop Off Areas: All light fixtures will be of a horizontal design with sharp cutoff edges. The fixture will be a rectangular box unit or a round puck -like unit (similar to Kim Lighting's Curvilinear Cutoff series) with a minimum diameter of 17" (width) and maximum diameter of 29" as detailed on Exhibit "K". The fixture will be made of spun aluminum or similar quality material with sidewalls free of welds or fasteners and will have an illumination source of mercury vapor or metal halide. All fixtures and light standards will have a black or dark bronze powder coated finish. Fixture glass must be white or clear. Light standards will be metal poles between 10 and 15 feet high. (refer to figure 2) -30- WALKWAY LIGHTING PARKING & ROADWAY LIGHTING 8. Landscaping. a. Existing Trees: Existing large mature trees will be retained in accordance with the Code. b. Tree Protection: All existing trees of six (6) inch caliper or greater must be indicated on the proposed site plans. The proposed site plans will indicate trees to remain and those to be removed. All trees within an approved building site which are required to be preserved in accordance with the Code must be flagged and encircled with protective fencing. The fencing must extend beyond the full spread on the tree's branches to reasonably ensure successful protection. Existing trees in parking areas will be saved in groups and as specimens whenever practicable. c. Open Space: All areas not containing buildings, structures, parking lots, sidewalks, fountains, site furniture or other improvements, including, but not limited to, front, side and rear building set back areas, and all areas between the curb line and the property line, must be planted, landscaped, and maintained in good condition. The landscape planting design must provide for easy maintenance. Utility easements will be landscaped consistent with other landscape areas where allowed by the respective utility company. d. Rights of Way: Areas within the road right -of -way may be landscaped only in accordance with a license agreement with the City. e. Grass: All landscaped areas not in groundcover or shrub beds will be planted in grasses, preferable sod. Overseeding in fall with cool season native grasses is allowed. The use of edging material to separate all grass areas from shrub and groundcover areas is required. The edging material will be concrete, steel, brick or La Profilers. East - PUD No. 38 Permitted Uses and Limitations Page 5 figure 2 -31- 9. Utility Lines. stone. No plastic edging is allowed. Use of narrow paving "mowstrips" are allowed around building foundations for easy maintenance. f. Irrigation: An underground, automatic irrigation system must be installed in all landscaped areas. Sprinkler heads must be located to effectively water the landscaped areas with minimal spray onto roadways, parking areas and walkways. g. Screening of Parking: Parking areas must be screened visually from all roadways in accordance with the Code. Screening may be accomplished with landscaping or buildings. Berms may not exceed a 3:1 pitch. Shrubbery must be maintained to a minimum height of 3 feet. (refer to figure 3) PARKING SHALL BE SCREENED FROM ROADWAYS STREET h. Parking Areas: In all vehicular use areas and parking areas, a minimum of 90 square feet for each 12 parking spaces must be devoted to landscaped strips, islands, peninsulas, medians, or other landscaped areas (the "Minimum Parking Area Landscaping Requirement"). As partial fulfillment of the Minimum Parking Area Landscaping Requirement, any parking area containing five or more parking rows of double vehicle depth will include a landscaped strip no less than ten feet (10 ") wide at least every fourth parking row of double vehicle depth. The landscaped strip will be installed with trees planted no less than every 60 linear feet. All utility service lines must be underground to connection points provided by the utility service provider. All transformers must be screened. La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 6 LANDSCAPE EASEMENT PARKING AREA figure 3 -32- La Frontera East - PUD No. 38 Project Identification Sign Locations Page 1 of 1 EXHIBIT E PROJECT IDENTIFICATION SIGN LOCATIONS RECORDERS I ORANDUM All or pmts of the text on this page was not clearly legible for satisfactory recordation. -33- La Fronter East - PUD No, 38 Combination Sign and Monument Sign Locations Page 1 of 1 EXHIBIT F COMBINATION SIGN AND MONUMENT SIGN LOCATIONS RECORDERS 0 is MI or pats of the text on this � r ,., clearly legible for satisfactory record- -34- La Fronter East - PUD No. 38 Utility Schematic and Drainage Plan Page 1 of 1 EXHIBIT G UTILITY SCHEMATIC AND DRAINAGE PLAN RECORDERS All or parts of the text on this pap was not clearly legible for satisfactory recordation. -35- ITEM QT' j DESCRIPTION TSWREF CU MU . 1XT* 1 I POLE. SCUARE STPnGNt. sTEa. PMt1E0 OAFR BRONZE ANCHOR 80.5E 20-110 sLps252040 0074M - FH 1 UJAIWRE VS NEDDI 11GUNTI. M. LE . 100 1 1 FDLNOAIION ELM 1 1 COW/ORM EN POW — aG 1 I POLE GAWK B 1OJXED pi FOU@OION 05 — 400. 400 Iv A7 — 1e00 toot 1 m KW 7717 AIO OObTEIgAL U910X servo 1400/00744D sa19e CA MALE uINIAPE WATTAGE TOLE 08047 X91 NERUIl 1XT* 1140411 tea. wnal 0074M MAX 1E 1)1 11GUNTI. M. m 100 116 27 a — aG 00 F - — 400. 400 Iv A7 — 1e00 toot 10' m 213 -530 10 -00 La Frontera East - PUD No. 38 Roadway Light Fixtures Page 1 of 1 EXHIBIT H ROADWAY LIGHT FIXTURES ' STREET LIGHT LUMINAIRE RECTANGULAR — UNDERGROUND .SQUARE STEEL POLE — ANCHOR BASE APPROVED BY TUELECTRIC 213 — 530 n -PS -36- EXHIBIT I PERMITTED OUTDOOR SALES AREA La Frontera East - PUD No. 38 Permitted Outdoor Sales Ages Page 1 of 1 RECORDERS MEMORANDUM All or ports of the teat on this page was r , clearly legible for satisfactory recordP -37- 0 cc EXHIBIT J SIDEWALK LOCATIONS Standard Sidewalks 0 ci La Frontera East - PUD No. 38 Sidewalk Locations Page 1 of 2 -38- d rc EXHIBIT J SIDEWALK LOCATIONS Wide Sidewalk La Front= East - MD No. 38 Sidewalk Locations Page 2 of 2 -39- PARKING LOT AND WALKWAY LIGHT FIXTURES SPECIFICATIONS AND DETAILS ARM MOUNT STANDARD ARM MOUNT MOUNTING OPTIONS Oman Vertical Sllpf ler Mount: /wows elendetd Ilslute and slpoctt arm lo be mounted to poles hevng e 2 • pipe site tenon (VW OD e a:. rum length) My rto tip mMtgua ou can he used (1 2a. 2L. 3T a OC1. S' dla. men alarm o m with flush cep. sawed . by ( W stemless greet set pant alien straws Finished to meth Mae end ern. h Horizontal Stlpgesr Mount Coal tA(rrtrsrn damp. type defter moue' with shuns set screw atWtumdon Jock 8dm 10 housing lrao Inside electrical OOTpa1F 'nitts using noutito Weak( standard support ems RAN clamps berry horizontal pole daNl inn vim pipe stns moucatng end (tit 0.D.). Finished to ' match fixture and amt. EXHIBIT K SPECIFICATIONS AND DETAILS POST TOP MOUNT MOUNTING OPTIONS La Frontera East - PUD No. 38 Parking Lot and Walkway Light Fixtures RECORDERS fORAN f Page 1 of 1 All or pens of the text on this pegs was r clearly legible for satisfactory record:. -40- La Fronter East - PUD No. 38 Traffic Impact Analysis Page 1 of 37 EXI -UnIT L TRAFFIC IMPACT ANALYSIS LA FRONTERA TRAFFIC IMPACT ANALYSIS Prepared For 35 / 45 Investors, L.P. Original Submission: September 1998 Interim Submission: November 1998 December 1998 Final Submission: February 1999 WHM -41- LA FRONTERA TRAFFIC IMPACT ANALYSIS Prepared For 35 / 45 Investors, L.P. 801 W. 10th Street Austin, Texas 78701 Phone: 512 - 322 -0112 Fax: 512- 322 -0124 Prepared by WHM Transportation Engineering Consultants, Inc. 2717 Rio Grande Street Austin, Texas 78705 Phone: 512- 473 -8343 Fax: 512- 473 -8237 Original Submission: September 1998 Interim Submission: November 1998 December 1998 Final Submission: February 1999 �PZE3 EX4 \ .. * B HEIDI RAE WESTERFIELD i / i t o= 82790 'ri ifF'TS/" .STE I. P.:G(2 : 2/ ioigq TABLE OF CONTENTS Page List of Figures i i List of Tables i i i Synopsis 1 Introduction 5 Site and Access Characteristics 5 Existing Thoroughfare System 5 Future Roadway Improvements 5 Traffic Analysis 6 1998 Existing Conditions 7 2004 Forecasted Conditions with Site Generated Traffic 10 Directional Distribution 10 Analysis Assumptions 13 Intersection Analysis 14 Driveway Spacing on Adjacent Roadways 19 Roadway Cross - Sections 25 Summary and Recommendations 30 References 32 LIST OF FIGURES - Fgure p 1 Area Location Map 3 2 La Frontera Parcels 4 3 Existing Traffic Volumes 8 4 Existing Lane Use and Level of Service 9 5 Site Traffic Distribution Before SH 45 Construction 15 6 Site Plus Forecasted Traffic Volumes Before SH 45 Construction 16 7 Site Plus Forecasted Lane Use and Level of Service Before SH 45 Construction 17 8 Site Traffic Distribution After SH 45 Construction 18 9 Driveway Locations Before SH 45 Construction 23 10 Driveway Locations After SH 45 Construction 24 11 Typical Street Section :. Hestees Crossing, La Frontera Boulevard, Parker Drive 26 12 Typical Street Section: Sundance Parkway (Western End), Kouri Drive 27 13 Typical Street Section: Sundance Parkway (Eastern End) 28 14 Typical Street Section: Northline Boulevard 29 WHM Transportation Engineering Consultants, Inc. LIST OF TABLES Table Page 1 Trip Generation Estimates - La Frontera Proposed Development 11 2 Adjusted Trip Generation Estimates - La Frontera Proposed Development 12 3 Forecast Directional Distribution of Site Oriented Traffic 13 WHM Transportation Engineering Consultants, Inc. iii LA FRONTERA TRAFFIC IMPACT ANALYSIS SYNOPSIS La Frontera is a 327 acre mixed -use development project located in southern Williamson County at the intersection of IH 35 and FM 1325 as shown in Figure 1. Proposed land uses include retail, office, hotel, cinema and restaurants. The site is bounded by 114 35 on the east, by FM 1325 on the south, by Quick Hill Road and undeveloped land on the west, and by a mixture of commercial and residential development on the north. Figure 2 shows a more detailed view of the La Frontera property and defines the parcels used for land use assumptions. The traffic - related characteristics of the proposed development activities require evaluation to determine their effect on the adjacent roadway network. An analysis was conducted that evaluated the impact of traffic generated by the project with the findings and recommendations reported herein. The purpose of the Traffic Impact Analysis (TIA) is to examine the interaction of existing and planned land use activities, their intensity and traffic characteristics , and identify actions that would create a successful, effective and safe development program under both existing and future traffic conditions. A TIA for the project was conducted utilizing accepted traffic engineering methods and techniques. Existing traffic conditions were examined on area roadways and at selected intersections and compared with traffic conditions that could be expected at buildout of the project considering both site generated and external (background) traffic. Based on the analysis, recommended actions were identified and are summarized as follows: The following recommendations are provided for traffic conditions existing prior to the construction of SH 45: (1) Hester's Crossing should be extended from its current termination point west of IH 35 through the site to Quick Hill Road. (2) A divided arterial should be constructed from Hester's Crossing to the south to intersect FM 1325 at the Limestone Ranch driveway. This intersection should be signalized. (3) Site circulation roadways being constructed as part of the project should align with Parker Drive and Northridge Drive. Parker Drive is assumed to be signalized. Recommended intersection geometrics are shown in Figure 7. (4) Adequate intersection spacing to allow appropriate left turn lanes and vehicle storage should be provided within the site, particularly along the proposed arterial extension from Hester's Crossing to FM 1325. (5) Dual left turn lanes should be provided along FM 1325 with the proposed signalized intersections discussed previously and as shown in Figure 7. This improvement'should be coordinated with TxDOT since FM 1325 is a state facility. (6) The benefits derived through trip generation reductions due to synergy among land uses will be increased for the proposed land uses due to the comprehensive roadway network proposed through the site and the ability for the network to distribute traffic to all directions without using adjacent roadways. (7) Capital Metro service is not currently available within the area of the site. For this reason, it will be desirable to encourage travel demand management as much as possible among the site land uses; i.e., car /van pools and staggered work hours. The following recommendations are provided for traffic operations in the vicinity of the site with the construction of SH 45: (1) An underpass should be constructed for FM 1325 to pass beneath the mainlanes of SH 45 to extend as an arterial north through the La Frontera site to Hester's Crossing. With the construction of SH 45, it will be necessary to realign FM 1325 to create a 90 degree intersection with the freeway frontage roads. The intersections of FM 1325 with the SH 45 eastbound and westbound frontage roads should be signalized. (2) Site internal roadway intersections with Parker Drive and Northline Drive will become right -in, right -out driveways as a result of the SH 45 freeway and frontage road construction. WHM Transportation Engineering Consultants, Inc. 2 NORTH RECORDERS MEMORANDUM All or parts of the text on this pa ga was ncr clearly legible for satisfactory recordst.' WHM Transportation Engineering Consultants, Inc. - Austin, Texas FIGURE 1 AREA SITE LOCATION r 3 m s 3. c INTRODUCTION La Frontera is a 327 acre mixed -use development project located in southern Williamson County at the intersection of 11-I 35 and FM 1325 as shown in Figure 1. Proposed land uses indude retail, office, hotel, cinema and restaurants. The site is bounded on the east by IH 35, on the south by FM 1325, on the west by Quick Hill Road and undeveloped land, and a mixture of commercial and on the north by residential development. It is projected that the development of this site will be completed by 2004. Site and Access Characteristics Figure 2 shows the location of development parcels within the project. Access for this project is proposed through site circulation roadways which connect to IH 35, FM 1325, Quick Hill Road, and Hester's Crossing. The internal roadway network will be constructed with the project development. Since the project is located along IH 35 and FM 1325 the programmed development activities and traffic related characteristics require evaluation. Examining the interaction of existing and programmed land use activities, their intensity and traffic characteristics is necessary to render an appreciation of appropriate actions required to create a successful, efficient, and safe program. This report on the analysis of the traffic conditions, present and future, addresses these objectives. EXISTING THOROUGHFARE SYSTEM As indicated on the area wide and site location maps (Figures 1 and 2), the project is located at the intersection of IH 35 and FM 1325. Other nearby roadways of importance include Hester's Crossing, Quick Hill Road, and Greenlawn Boulevard. The interrelationship of these roadways and others in the area is shown on the previous Figure 1. FUTURE ROADWAY IMPROVEMENTS Several pertinent roadway improvements have been recommended and approved by the Round Rock City Council, Williamson County Commissioner's Court, and the Texas Department of Transportation (Ref. 1, 2). WHM Transportation Engineering Consultants, Inc. 5 TRAFFIC ANALYSIS Hest is rosain . Hester's Crossing will be extended from its current termination point west of IH 35 through the site to Quick Hill Road as a part of project development. FM 1325 (SH 451: The Texas Turnpike Authority has underway a consultant contract to prepare route location, environmental studies, tollway studies, and preliminary design for SH 45 from Lakeline Boulevard to south of the San Gabriel River. The current alignment falls within the southern portion of the project site. A portion of FM 1325 is planned for reconstruction and realignment as a part of the construction of SH 45. Current plans include realignment of FM 1325 to intersect the eastbound SH 45 frontage road midway between IH 35 and Loop 1. Development of La Frontera anticipates the realignment and extension of FM 1325 to the north to Hester's Crossing. This roadway would be extended beneath the SH 45 main lanes and create signalized intersections with the frontage roads. A request has been submitted to the Round Rock City Council for inclusion of this arterial extension on the City's Thoroughfare Plan. SH 45 will most likely not be constructed prior to buildout of the La Frontera site Greenlawn Boulevard: This street currently intersects CR 170 (Louis Henna Boulevard) east of IH 35. Current plans include extension of this roadway to the south to intersect the northbound frontage road of IId 35. Ultimate plans include overpasses at SH 45 and 1H 35. In order to assess the traffic implications of the proposed development, two time periods and travel conditions were evaluated: (1) 1998 - Existing Conditions (2) 2004 - Forecasted with Site Generated Traffic Conditions Intersections in the vicinity of the site are considered the locations of principal concern because they are the locations of highest traffic conflict and delay. The standard used to evaluate traffic conditions at intersections is Level of Service (LOS), which is a qualitative measure of the effect of a number of factors such as speed, volume of traffic, geometric features, traffic interruptions, freedom to maneuver, safety, driving comfort, convenience, and operating cost. WHM Transportation Engineering Consultants. Inc. 6 Analysis was performed using the microcomputer program "Highway Capacity Software" by the Federal. Highway Administration (Ref. 3), which is based on the procedures contained in the Highway Capacity Manual (Ref. 4), as well as PASSER III (Ref. 5). 1998 Existing Conditions The analysis of existing traffic required the acquisition of secondary data from the City of Round Rock, as well as the collection of primary data on the major roadways and intersections. A field survey was designed through discussions with City staff and implemented to obtain the necessary data and to verify the trends established by data available from previous years. Signalized Intersections The following intersections within the study area are signalized: • IH 35 and Hester's Crossing • FM 1325 and CR 172 (Quirk Hill Road) • FM 1325 and Northridge Road Existing peak hour traffic volumes at the above intersections and other locations adjacent to the site are presented in Figure 3. Current lane use and level of service are summarized in Figure 4. WHM Transportation Engineering Consultants, Inc. 7 -a p. 5 551 170 0 207 1 442 1 NORTH NOT TO SCALE LA FRONTERA SITE .*----1449/1573 4/68 1682/1526 , 1651/1384 -t '5 / T 13/51 � ♦ 130/12 -� 114 �� A .00 11 \\ 48 29 3 5 ' � g61161h /y O 14 33 30 611 O I 30 430 325 1 889 569 J HESTER'S CROSSING I 105/263 -► 1 120/155 } w- 1519/1518 f- 160/67 1 AM = PEAK HOUR VOLUME -4----133/440 f - 867/720 160/406 270/426 -0 ' 1 1 1 1023 x W N 2_4711 2009 FM 1325 1 11 60 - ° 382 FIGURE 3 CR 170 EXISTING TRAFFIC VOLUMES ri NO TH Ip NOT TO SCALE ld LA FRONTERA SITE r HESTER'S CROSSING W■ —► 1 r FM 1325 I CR 170 FIGURE 4 EXISTING INTERSECTION LEVEL OF SERVICE 2004 Forecasted Conditions With Site Generated Traffic The year 2004 was established as the year in which the project would become fully occupied. This time frame was utilized to assess the major roadway effects and to facilitate the evaluation of alternative improvements. Forecasted traffic was projected using available information. This process was facilitated by using trends established by prior data for the major roadways in the immediate vicinity of the project site. Site Generated Traffic Determining the generated traffic or the traffic which is considered to be contributed by development of the proposed project was a major analysis process element. Total trips per day as well as the peak hour traffic associated with the project were estimated using the microcomputer program 'Trip Generation" by Microtrans Corporation (Ref. 6), which is based on recommendations and data contained in the Institute of Transportation Engineers report Trip Generation (Ref. 7). Table 1 provides a detailed summary of the traffic production which is directly related to the assumed land use activity. As a point of reference, the total PM peak hour trips were estimated at 9,588. Table 2 summarizes trip generation estimates which have been adjusted in accordance with analysis assumptions discussed in the following. section. The adjusted total PM peak hour trip generation is 7,122. Directional Distribution Once site generated trips were known, the next step involved distribution of those trips to appropriate geographic directions and logical connecting roadways. The major thoroughfares which have a direct bearing on the accessibility of the project have been previously identified. Traffic counts conducted during the study provided the basis for the directional distribution of traffic approaching and departing the project site as summarized in Table 3. Given the total site generated traffic and the directional distribution by approach, the next step in the process was to assign the traffic destined to and from the project to the most likely travel paths. This was done by investigating a number of alternative travel patterns as well as ingress /egress points along the project boundaries. Primary consideration was given to the traffic flow and safety of the major roadways. WHM Transportation Engineering Consultants, Inc. 10 TABLE 1. TRIP GENERATION ESTIMATES - LA FRONTERA PROPOSED DEVELOPMENT Lot Number Land Use Size SF Daily Traffic Volume AM Peak Hour Enter Exit PM Peak Hour Enter Exit Buildout Year 1 Office 35,937 605 73 10 20 99 1999 2 Office 55,539 845 103 14 24 117 1999 3 Office 118,701 1,514 188 26 36 176 2000 4 Office 52,272 806 98 13 23 114 2000 5 Office 74,052 1,054 129 18 28 135 2000 6 Office 126,324 1,588 198 27 38 183 2002 7 Office 287,496 3,165 395 54 73 356 2001 8 Office 392,040 4,316 538 73 99 485 2003 9 Office 63,162 933 114 16 26 125 2002 10 Office 141,570 1,733 216 30 40 198 2003 11 Office 202,554 2,230 278 38 51 250 2004 12A Office 99,317 1,320 163 22 32 158 2001 12B Office 99,317 1,320 163 22 32 158 2002 13 Office 167,706 1,974 248 34 45 222 2000 14A Hotel 200 rms 1,646 68 44 65 57 2000 14B Office 200,376 2,206 275 38 51 248 2000 16 Hotel 120 rms 988 41 26 39 34 2004 17 Hotel 120 rms 988 41 26 39 34 1999 18 Hotel 90 rms 741 31 20 29 26 1999 19 Hotel 90 rms 741 31 20 29 26 2000 15 +28 Cinema 4500 seats - - - 334 296 2000 20 Restaurant (HT Sit-down) 10,454 1,363 50 47 68 45 2000 21 Reotaurant (HT Sit -down) 8,886 1,158 43 40 58 39 2000 22 Restaurant (HT Sit-down) 9,409 1,226 45 42 61 41 2000 23 Restaurant (HT Sit-down) 5,750 749 28 26 37 25 2000 24 Restaurant (HT Sit-down) 5,750 749 28 26 37 25 2001 25 Restaurant (HT Sit-down) 11,500 1,499 55 51 75 50 2001 26 Restaurant (HT Sit-down) 9,932 1,295 48 44 65 43 2001 27 Restaurant (HT Sit-down) 11,500 1,499 55 51 75 50 2001 29 Shopping Center 607,727 26,084 382 244 1,091 1,182 1999 Subtotal 2,797,271 66,335 4,125 1,142 2,720 4,997 620 rms 4,500 seats Wedge Shopping Center 1,306,800 12,339 181 115 516 559 2001 Wedge Shopping Center 435,600 4,113 60 38 172 186 2002 Wedge Office 653,400 3,237 404 . 55 74 364 2003 Subtotal 2,395,800 19,689 645 208 762 1,109 TOTAL Trips 86,024 4,770 1,350 3,482 6,106 WHM Transportation Engineering Consultants, Inc. 11 TABLE 2. ADJUSTED TRIP GENERATION ESTIMATES LA FRONTERA PROPOSED DEVELOPMENT Lot Number Land Use Size SF Daily Traffic Volume AM Peak Hour Enter Exit PM Peak Hour Enter Exit Buildout Year 1 Office 35,937 514 62 9 17 84 1999 2 Office 55 539 718 88 12 20 99 1999 3 Office 118,701 1,287 160 22 31 150 2000 4 Office 52,272 685 83 11 20 97 2000 S Office 74,052 896 110 15 24 115 2000 6 Office 126 324 1350 168 23 32 156 2002 7 Office 287,496 2,690 336 46 62 303 2001 8 Office 392040 3,669 457 62 84 412 2003 9 Office 63,162 793 97 14 22 106 2002 10 Office 141570 1,473 184 26 34 168 2003 11 Office 202554 1896 236 32 43 213 2004 12A Office 99317 1,122 139 19 27 134 2001 126 Office 99 317 1,122 139 19 27 134 2002 13 Office 167,706 1,678 211 29 38 189 2000 14A Hotel 200 rms 1,399 58 37 55 48 2000 148 Office 200 376 1,875 234 32 43 211 2000 16 Hotel 120 rms 840 35 22 33 29 2004 17 Hotel 120 rms 840 35 22 33 29 1999 18 Hotel 90 rms 630 26 17 25 22 1999 19 Hotel 90 rms 630 26 17 25 22 2000 15 +28 Cinema 4500 seats - 284 252 2000 2D Restaurant (HT Sitdown) . 10,454 645 26 24 35 23 2000 21 Restaurant (HT$it -1 own) 8886 591 22 20 30 20 2000 22 Restaurant (HT Sit down) 9,409 625 23 21 31 21 2000 23 Restaurant (HT Sitdown) 5750 382 14 13 19 13 2000 24 Restaurant (HT Sit down) 5,750 382 14 13 19 13 2001 25 Restaurant (HT Sit down) 11500 764 28 26 38 26 2001 2G Restaurant (HT Sit down) 9,932 660 24 22 33 22 2001 27 Restaurant (HT Sitdown) 11 500 764 28 26 38 26 2001 29 Shopping Center 607,727 1G,407 240 153 686 743 1999 Subtotal 2,797,271 47,377 3,302 806 1,909 3,878 620 rms 4,500 seats Wedge Shopping Center 1306800 8,495 125 79 355 385 2001 Wedge Shopping Center 435,600 2552 37 24 107 115 2002 Wedge Office 653,400 2,751 343 47 63 309 2003 Subtotal 2395 800 13,799 505 150 525 810 TOTAL Trips 61,176 3,807 955 2,434 4,688 f.i WHM Transportation Engineering Consultants, Inc. 12 Table 3. Forecast Directional Distribution of Site Oriented Traffic ' Direction % of Site Traffic Ent�nQ Exiting North on IH35 25 25 South on IH 35 30 30 West /south on FM 1325 30 30 East on Louis Henna Boulevard 5 5 Easton Mays Street 5 5 North on Quick Will Road _5 — Total 100 100 Analysis Assumptions The traffic impact analysis process involves the use of primary data and engineering judgment on transferable parameters. Specifically, engineering judgment is required for estimation of background traffic growth and transit trip reductions, both of which are further described. below: Background Traffic Background traffic volumes were determined based on an annual growth rates along FM 1325 as well as data contained in a recent study conducted for the City of Round Rock (Ref. 8). Pass -By Capture Studies have shown that retail land uses will capture from 20 to 60 percent of their traffic as pass -by trips, depending upon their size (Ref. 7). It is well documented that many other land uses also experience significant pass -by trip capture, such as fast food restaurants. The amount of trip reduction which each tract may attribute to the pass -by phenomenon will depend directly on the type of land use which is developed. Internal tore Once the total buildout of proposed land uses occurs, there will be interaction among the uses within this development. Internal capture is accounted for in two ways. First, to account for internal capture among similar retail land uses in adjacent areas, the sizes may be combined during the trip generation process. Because the equations used in trip generation estimations are logarithmic, the number of trips generated by a site WHM Transportation Engineering Consultants, Inc. 13 does not increase in direct proportion to an increase in the square footage of a development. By combining retail projects in dose proximity to each other, a lower number of trips will be estimated, thereby taking into account the internal capture factor. The second way to account for internal capture is to reduce the expected number of trips directly by some percentage which reflects expected multipurpose trip - making among different types of land uses which are in dose proximity. However, as with pass -by trip reductions, internal capture depends ort the type and quantity of land uses. Intersection Analysis The total 2004 traffic demand will be the sum of traffic generated by this proposed development, traffic generated by other development projects, and changes in existing traffic. Figure 5 summarizes projected AM and PM peak hour site traffic volumes at study area intersections prior to construction of SH 45. Buildout year AM and PM peak hour traffic volumes, including both site and background traffic, at study area intersections are presented in Figure 6. Recommended lane use and level of service analysis results are summarized in Figure 7. Upon completion of the construction of SH 45, access to the site will differ from that which will exist upon initial development. Planned modifications to the roadway network were described previously. Figure 8 illustrates projected site traffic volumes within the study area which will result from the roadway system modifications. WHM Transportation Engineering Consultants, Inc. 14 190 122 1 31 '05" —r 1 \\___ 48%234 15/80 1 1 M NORTH NOT TO SCALE LA FRONTERA SITE 474 1 b 11l 31 89 1 i h /� 'A C$ HESTER'S CROSSING 258 l� JI 256/1290 — . I 89/488 --- "N4 I 381 5601 99/373 . — 691/384 70/103 208/1056 48/234 ---,••• 1 83 57 1 277 1 367 261 J I , 86 '/L 1041151601 .11.----335/309 i I 560/274 1 475 } 265/210 � 121/176 1313 ) \ ....: "../....i.........2:0,..' i ____,r e.:+ 162/425 98 /510 —r 4 AM = PEAK HOUR VOLUME 156 739 .*---- 190/122 571 365 R1 FM 1325 CR 170 FIGURE 5 SITE TRAFFIC BEFORE SH 45 CONSTRUCTION 608 190\ 188 122 1 48/234 15/80 I 1 229 200 488 F' 1 NORTH NOT T O SCALE LA FRONTERA SITE HESTER'S CROSSING �— -/1101 -/1290-7–r•- -/297 � -/782 -- 1 1 2878 3 2778 1 1 $3 _EZ 54 62 1 1 5 367 261 199 277 1 2 p9► 8 N� 278/164 \____ 256/285 I _M ...„,--1061 l X2032/2606 J �t 2330/24431 1 4 ).„.... 1 2 .01 ) / � 4 /75 //F �- 302/112 , � 1 1 � �3 � 265/210 _� R � / 121/176 __l x� g31 i ,,,, l4/56 1 243/20 38 6000)\„4„. 125 �� 32 �\ 66 53 ---N, 8 95 '21°' e 1 � 2 0 � 36 x 17 33 159 313 1 1 1. 9 p 9 En 0 c M - PEAK HOUR VOLUME gg 590 3 /+ O E =' = INFORMATION NOT AVAILABLE FM 1325 1 CR 170 FIGURE 6 SITE + FORECASTED TRAFFIC BEFORE SH45 CONSTRUCTION a A a F 0 A HESTER'S CROSSING LA FRONTERA SITE NORTH ■■ 1 � NOT TO SCALE l 1 C �- J II F l D l AT, AtCpR =' = INFORMATION NOT AVAILABLE M FM 1325 CR 170 FIGURE 7 SITE + FORECASTED INTERSECTION LEVEL OF SERVICE 1 0 25 165 26 95 1� 271 181 1 1 . 212/73 _, ▪ 272/136 — 41/42 — \ 711 x F.: 40/194 13/66 • 1 7 175 40 179 1 F 41 50 O g) e 5 57 10 29 g 21473T A 48/9 A0 - — 60/285 A 227/106 2� u � 32 188 348/287 1 NORTH NOT TO SCALE LA FRONTERA SITE 25 243 106 597 310/140 / 1 -4--- 85/169 iii 1 73 148/71 302 -4--255/195) 4: sr.. 509 63 MT 107 f � 663/344 HESTER'S CROSSING 32/63 _154/125 649 /626 161 /787 � 255/1290 —� 90/488 —� 1 381 523 99/373N 73 J Il k-161/179 730/459 — = PEAK HOUR VOLUME 208/1096 _J 47/194 —• m 16 t i I2 467 185 1 107 561 14 212/73/ ` fi 7 61/63 27 63/326—.../ — \ 15 21 1:5 / 142 \ T �9 J 575 FIGURE 8 SITE TRAFFIC AFTER SH 45 CONSTRUCTION 190 121 SH45 NFR SH45 SFR DRIVEWAY SPACING ON ADJACENT ROADWAYS The La Frontera site will be developed along the IH 35 West Frontage Road and FM 1325. When SH 45 is constructed through the area, the site will be located along the SH 45 North Frontage Road; FM 1325 will be realigned to intersect with La Frontera Boulevard within the La Frontera site. In order to provide for safe and efficient traffic operations in and around the La Frontera site, a comprehensive internal roadway network will be constructed as part of site development. With the high level of activity on roadways surrounding the site, it is desirable to move traffic from adjacent roadways into the site as efficiently as possible. The following recommendations have been developed for driveway locations along IH 35, FM 1325, and proposed SH 45. In general, it is recommended that a minimum 300 foot driveway spacing be maintained for the•La Frontera site. As is always the case, driveways should be spaced as far apart as possible. Reflected in the following paragraphs are compromises developed between the City of Round Rock staff and the developer of the property on the number of driveways to be permitted within each section of roadway. The proposed driveway spacing and locations have been proposed in order to address City of Round . Rock : requirements ° Any changes to proposed roadway alignments, intersection locations, or driveway spacing requirements described in the following paragraphs must be approved by the City of Round Rock. FM 1325 The La Frontera site will access FM 1325 via three future connections at Parker Drive, La Frontera Boulevard, and Northridge Road /Northline Drive. Given existing traffic conditions along FM 1325, additional access to the site via left turns is not recommended. The three proposed roadways which will provide left turn access from FM 1325 into the site will be sufficient to handle left turn demands. The roadways will be constructed to connect with additional internal site roadways, and will provide for efficient circulation within the site. As shown in Figure 9, as part of the internal roadway network, the developer proposes to construct a section of roadway between Parker Drive and La Frontera Boulevard at the future location of the SH 45 North Frontage Road to provide access to Kouri Avenue. When SH 45 is constructed, this internal connector roadway will no longer be necessary. WHM Transportation Engineering Consultants, Inc. 19 In addition to the fully directional access locations along FM 1325, WI had proposed a limited number of right -in, right -out (RIRO) driveways to be constructed approximately midway between site access roadways with physical barriers (a raised median section) to prohibit Left turn maneuvers into and out of the La Frontera site. At the request of the City of Round Rock, the property owner has agreed to construct only one limited access service driveway on the east side of the property frontage along FM 1325. Access to this driveway will be restricted to delivery vehicles. A crash gate will be installed on -site which will prevent the use of this driveway by the general public to access the remainder of the La Frontera development. Therefore, the only access along FM 1325 which will be available for use by the general public will be provided via the Parker Drive, La Frontera Boulevard and Northridge Road /Northline Drive intersections. IH 35 West Frontage Road Figure 9 shows a conceptual diagram of the site prior to construction of SH 45 (distances are dimensioned for reference purposes). A southbound exit ramp is located along the section of the IH 35 West Frontage Road in front of the La Frontera site. At a minimum, TxDOT requires that access be prohibited 50 feet upstream from the intersection of travelways of the ramp and the frontage road, and for a distance of 250 feett downstream from the intersection of travelways. The access - denied area of 300 feet which has been noted on Figure 9 is associated with the exit ramp. Sundance Parkway is proposed to be constructed on the La Frontera site approximately 380 feet south of the access - denied area associated with the exit ramp. This roadway will serve as a primary collector for La Frontera traffic. It is recommended that no site driveways be constructed between Sundance Parkway and the IH 35 exit ramp since weaving maneuvers will be occurring in this section. However, an additional driveway should be permitted north of the 300 foot access - denied area associated with the ramp (see Figure 9). In the future, the existing [H 35 southbound exit ramp is proposed to be removed in conjunction with construction of the IH 35 /SH 45 directional interchange. The City of Round Rock has indicated the desire to provide no additional driveways when the exit ramp is removed. The La Frontera property developers have agreed to the restriction requested by the City of Round Rock and will maintain the two proposed access points after the IH 35 ramp is removed. The number of access points will not be increased at WHM Transportation Engineering Consultants, Inc. 20 any time in the future; however, the City of Round Rock has indicated it will consider the possibility of shifting access point locations along 11-135 frontage after removal of the existing exit ramp. - SH 45 When FM 1325 is replaced with SH 45, the La Frontera site will front the SH 45 North Frontage Road as shown in Figure 10. Access roadways from the SH 45 North Frontage Road into the La Frontera site will include Parker Drive, Kouri Avenue, La Frontera Boulevard, and Northline Drive. With the exception of La Frontera Boulevard, each of these access roadways will function as a RIRO roadway. La Frontera Boulevard is proposed to connect to FM 1325 south of SH 45. Based on discussions with the Texas Turnpike Authority and Turner Collie and Braden, Inc., the SH 45 westbound exit ramp which will serve the La Frontera site will be located east of Parker Drive. The limited access service driveway east of Parker Drive which will access FM 1325 prior to construction of SH 45 will most likely require removal due to access control restrictions associated with the SH 45 exit ramp. All weaving will be accomplished prior to vehides reaching Parker Drive. WHM has recommended that the section of La Frontera frontage along the SH 45 North Frontage Road should be restricted with a minimum driveway spacing requirement of 300 feet. However, in order to address comments from the City of Round Rock, proposed driveway locations have been restricted. Figure 10 shows proposed driveway locations. As shown on Figure 10, one driveway should be permitted between Parker Drive and Kouri Avenue, no driveways between Kouri Avenue and La Frontera Boulevard, two driveways between La Frontera Boulevard and Northline Drive, and one driveway between Northline Drive and the western property line.. At no time should driveways be spaced less than 300 feet from each other or access roadways into the site. The single driveway proposed between Parker Drive and Kouri Avenue should be located midway between the two roadways (providing an approximate spacing of 360 feet between access points). This driveway will serve as a RIRO driveway for seven restaurant tracts. WHM Transportation Engineering Consultants. Inc. 21 The two driveways proposed between La Frontera Boulevard and Northline Drive will serve five tracts (two limited - service hotel tracts and three office tracts). The bruited- service hotel tracts are shallow tracts which front the SH 45 frontage road and are located immediately west of La Frontera Boulevard. The provision of a single RIRO driveway to these two tracts will provide better operating conditions than the required configuration if the driveway were not constructed. If not permitted, a fully-directional access point to these sites would be required on La Frontera Boulevard. Since these sites are shallow in depth, it would be necessary to locate a median opening on the proposed arterial (La Frontera Boulevard) 150 to 200 feet north of the SH 45 frontage road. With a proposed underpass at the La Frontera Boulevard and SH 45 intersection, more than 200 feet will be required for queue storage of southbound traffic on La Frontera Boulevard. By providing a BIRO driveway on SH 45, a median opening on La Frontera Boulevard can be eliminated, thus providing more efficient operating conditions for all traffic traveling through the La Frontera Boulevard /SH 45 intersection. The additional driveway proposed in the section between La Frontera Boulevard and Northline Drive will serve the remaining office tracts. WHM Transportation Engineering Consultants, Inc. ,p 1 NORTH NOT TO SCALE z LA FRONTERA SITE No Driveways HESTER'S CROSSING I 3 - I 300' 1 3841 SUNDANCE PKWY. 5 I 2 0I 1450' 1700' Limited Access Service Driveway O Access Denied FIGURE 9 FM 1325 DRIVEWAY LOCATIONS BEFORE SH 45 CONSTRUCTION 800 1400' NORTH NOT TO SCALE LA FRONTERA SITE 1 Driveway d 2 Driveways �13 if ► No Driveways 1 650' 1 lam....... HESTER'S CROSSING 'I o - I 300'il I SUNDANCE PKWY. , •I al 1 Driveway rd 1 380 720' 1700' Access Denied FIGURE 10 SH45 NFR SH45 SFR DRIVEWAY LOCATIONS AFTER SH•45 CONSTRUCTION ROADWAY CROSS - SECTIONS A well - developed internal circulation network will provide efficient access into and out of the site. The proposed roadway network which will provide for internal circulation among land uses was shown in Figure 10. Patterns of egress and ingress were examined to determine the projected demand on each internal roadway. From there, appropriate cross - section recommendations were developed based on future vehicular traffic demands, pedestrian patterns, and land use requirements. Roadway cross - section recommendations are provided in the following figures (Figures 11 through 14). WHM Transportation Engineering Consultants, Inc. 25 K ^1 ; O 2 p 1 14.0' T n 2,0' 10.0• `2.0' • 2 SIDEWALK .1 I ZONE n. R O G 1 Ft 1 SIDEWALK " PT 3I 5.0' . i 24.0' 16.0' 100' 4.0.w. O 16,0' 0 r 3 24.0• t.0 5.0' N.T.S. 14.0' 2. 0{ 10.0' 3 2.0• SIDEWALK 1 ZONE SIDEWALK ELECTRIC C0SERVE TRENCH FIGURE 11 TYPICAL STREET SECTION NESTER'S CROSSING LA FRONTERA BOULEVARD PARKER DRIVE z 0 8 m 10 3. S 14.0' 2.0' 10.0 SIDEWALK I ZONE 2.0 80 0.O.w. 14.0' FIGURE 12 TYPICAL STREET SECTION SUNDANCE PARKWAY (WESTERN END) KOURI DRIVE N.T.S. 3 8 0 m 0 P. go C 0 0 0 15.0' 2.0' 10.0' ` 5.0' SIDEWALK 1 ZONE 5.0' SIDEWALK 0 k 3 j 5.0' 2.0' 70' R.O.W. 56..0' g, O u l 6.0 § 2.0 15.0' 0 1 10.0' ` 2.0 SIDEWALK 1 I ZONE 5.0' CNSERVE TRENCH FIGURE 13 TYPICAL STREET SECTION SUNDANCE PARKWAY (EASTERN END) N.T.S. B 0 70 2 0. A H 0 5.0' 1..5' 2.0' 10.0' + 2.5' SIDEWALK 20HE 20' N.O.W. 52.0' SIDEWALK o 0 p gI 2 I 1 1. 6 N l ' I 5.0' z 6.0' 6.0' W t Vgi 100 2.5' 10.0' 2.0' I SIDEWALK 1 1 ZONE 1 5.0' CoSERVE TRENCH FIGURE 14 TYPICAL STREET SECTION NORTHLINE BOULEVARD N.T.S. SUMMARY AND RECOMMENDATIONS The preceding analyses have illustrated the effects of site generated and forecasted traffic demand upon the street and roadway network adjacent to and in the vicinit of the project site. Generated traffic volumes were developed in a conservative scenario and assuming complete site development by 2004. Based on the analysis of existing and projected conditions and in order to provide the safest and most effective movement into and out of the site, the following recommendations were developed. The following recommendations are provided for traffic conditions existing prior to the construction of SH 45: (1) Hester's Crossing should be extended from its current termination point west of IH 35 through the site to Quick Hill Road. (2) A divided arterial should be constructed from Hester's Crossing to the south to intersect FM 1325 at the Limestone Ranch driveway. This intersection should be signalized. (3) Site circulation roadways being constructed as part of the project should align with Parker Drive and Northridge Drive. Parker Drive is assumed to be signalized. Recommended intersection geometries are shown in Figure 7. (4) Adequate intersection spacing to allow appropriate left turn lanes and vehicle storage should be provided within the site, particularly along the proposed arterial extension from Hester's Crossing to FM 1325. (5) Dual left turn lanes should be provided along FM 1325 with the proposed signalized intersections discussed previously and as shown in Figure 7. This improvement should be coordinated with TxDOT since FM 1325 is a state facility. (6) The benefits derived through trip generation reductions due to synergy among land uses will be increased for the proposed land uses due to the comprehensive roadway network proposed through the site and the ability for the network to distribute traffic to all directions without using adjacent roadways. WHM Transportation Engineering Consultants, Inc. 30 ( Capital Metro service is not currently available within the area of the site. For this reason, it will be desirable to encourage travel demand management as much as possible among the site land nsos; i.e., car /van pools and staggered work hours. The following recommendations are provided for traffic operations in the vicinity of the site with the construction of SH 45: (1) An underpass should be constructed for FM 1325 to pass beneath the mainlanes of SH 45 to extend as an arterial north through the La Frontera site to Hester's Crossing. With the construction of SH 45, it will be necessary to realign FM 1325 to create a 90 degree intersection with the freeway frontage roads. The intersections of FM 1325 with the SH 45 eastbound and westbound frontage roads should be signalized. (2) Site internal roadway intersections with Parker Drive and Northline Drive will become right -in, right -out driveways as a result of the SH 45 freeway and frontage road construction. WHM Transportation Engineering Consultants, Inc. 31 REFERENCES 1. Austin Metropolitan Area Transportation Plan, Austin Transportation Study, December 12, 1994. 2. City of Round Rock Thoroughfare Plan, Update study underway by Rust Lichliter /Jameson_ 3. "Highway Capacity Software," United States Department of Transportation, Federal Highway Administration, January 1995. 4. Highway Capacity Manual (SR 209), Transportation Research Board, Washington, D.C., 1994. 5. PASSER III - 90, Texas Transportation Institute, Texas A &M University, College Station, Texas, March 1991. 6. Buttke, Carl H., 'Trip Generation," Microtrans Corporation, Portland, Oregon, 1997. 7. Trip Generation, 6th Edition, Institute of Transportation Engineers, Washington, D.C., 1997. 8. Traffic Study of the Southeast Commercial Access Plan, City of Round Rock, Rust Lichliter /Jameson, June 1998. WHM Transportation Engineering Consultants, Inc. 32 FILED MD RECORDED } OOFFICIAL PUBLIC RECORDS 07 -30 -1999 04:36 PM 199951346 STRICKLAND $167.00 NANCY E. RISTER :COUNTY CLERK WILLIAMSON COUNTY, TEXAS Pitout kukuwu ho - I )bITY OF ROUND ROCK �/ ADMINISTRATION 221 EAST MAIN STREET ROUND ROCK, TEXAS 78664 Permitted Use* Building Height Limitation ** Building Setbacks from: Nester's Crossing Kouri Avenue South of Stp da North of S Pdanyce Other Roads Gen. Comm. (C -1) 45 feet 60 feet 25 feet 25 feet 15 feet 25 feet Shopping Center 45 feet 60 feet 25 feet 25 feet 15 feet 25 feet Restaurant * ** 45 feet 60 feet 25 feet 25 feet 15 feet 25 feet Cinema 65 feet 60 feet 25 feet 25 feet 15 feet 25 feet Office 45 feet 60 feet 25 feet 25 feet 15 feet 25 feet AdmcaUs-)ragive) Aaheridm.e d- 40 iUP ID Id I d.ln9 S et bc.cs Illlllllllllnlllillnllllllllllllllllllllll�llllll [111111 AMEN 10 P GS Mayor Nyle Maxwell Mayor Pro -tem Alan McGraw Council Members Tom Nielson Carrie Pitt Scot Knight Scott Rhode Gary Coe City Manager James R. Nuse, P.E. City Attorney Stephan L. Sheets ROUND ROCK, TEXAS PURPOSE. PASSION. PROSPERITY. November 5, 2004 Mr. Rick Albers Kuperman, Orr, Rial & Albers 811 Barton Springs Road, Suite 730 Austin, Texas 78704 RE: Administrative Amendment to PUD 38, building setbacks Dear Mr. Albers: Further to your request for an administrative modification of the building setbacks in PUD 38 (La Frontera), I have made the following administrative amendment as provided for by section 1.1 of "III. Miscellaneous Provisions" in Exhibit B of the PUD Agreement. Exhibit D, Paragraph 1, is deleted in its entirety and replaced with the following: 1. Permitted Uses, Heights and Setbacks. Permitted uses, building height limitations, building setbacks and landscaping setbacks are detailed in the chart below: Zoning designations noted in parentheses indicate all uses permissible under the Code for such designation as of the date of the Ordinance. Such uses may include, but are not limited to, other uses also listed in this chart, Limitations for any specific C -1 use listed in this chart will control over the general C -1 listing. Decorative architectural features may exceed the stated height limitation by 15 feet except that decorative architectural features in connection with a cinema may exceed the stated height limitation by 30 feet. Including bar and liquor sales. Z- 99 -0.- -/ 33 2004093328 CITY OF ROUND ROCK Planning and Community Development Department Sot West Bagdad • Round Rock, Texas 78664 Phone: 512.2[8.5428 • Fax: 512.218.3286 • www.ci.round rock.tx.us T Sincerely, • • The above amendment is intended to accommodate the exact location of the buildings along the north side of Sundance Parkway. Stendebach, AICP Director of Planning Tom Word, P.E. Chief of Public Works Operations Charles Cro City Attorney THE STATE OF TEXAS COUNTY OF WILLIAMSON § BEFORE ME, the undersigned authority, on this day personally appeared Jim Stendebach, known to me to be the person whose name is subscribed to the foregoing instrument as the Director of Planning of the City of Round Rock, Texas, a municipal corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNER MY HAND AND SEAL OF OFFICE, this the 9 day of , 2004. THE STATE OF TEXAS Public Signature State of Texas COUNTY OF WILLIAMSON § BEFORE ME, the undersigned authority, on this day personally appeared Tom Word, known to me to be the person whose name is subscribed to the foregoing instrument as the Chief of Public Works Operations of the City of Round Rock, Texas, a municipal corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UND R MY HAND AND SEAL OF OFFICE, this the I /day of 004. 1�aILiIi1 THE STATE OF TEXAS COUNTY OF WILLIAMSON § BEFORE ME, the undersigned authority, on this day personally appeared Charles Crossfield, known to me to be the person whose name is subscribed to the foregoing instrument as City Attorney of the City of Round Rock, Texas, a municipal corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVE I ER MY HAND AND SEAL OF OFFICE, this the /day of 2004. • • Notary Public Signature State of Texas tary Public Signature State of Texas • AGREED TO BY OWNER: Name: iiarill<. R • 4 N Title: MO ■0�wT BALTEM DE kOPMENT CORPORATION, a Missouri c oration BARGET DE I OPMENT CORPORATION, a Missouri co ration Name: it -1•i &S R• Cr(Z6F■ Title: PR65016N 1 KARJOY DEVELOPMENT CORPORATION, a Missouri By: Name: kaoU (L• GREEN Title: PMS% MAXLAND D ,,// OPMENT CORPORATION, a Missouri co r:ration ame: 1110t-AAS It— GRECN Title: PR6511) it JOPAT BUILD 1 ORPORATION, a Missouri cot . : ion By: — Name: 1140NAf IL G0. 66N Title: PRF,S 1 O 6t33i • • NATURAL B a Missouri Corp 11A0mAS (C • GQ thN Title: P(CF,S 19 fiNT PAJIA REALTY T' ORATION, a Missouri corp I ... n By: N. 'fi lar+AS it. G Title: PRGS tb FN T THIRD CREEK L.L.C., a Missouri limited liability corn By: Name: HATTN +kc h.2F;Nr4F,R Title: MANAtiFR_ DELMAR PROP' : ! S, a Missouri gen artnership •� ! S4tnrtAS R. W04 6" Title: PART+JM_ n • EVELOPMENT CORPORATION, • • THE STATE OF hjyoESmii § COUNTY OF 2# )5ai 4 § BEFORE ME, the undersigned authority, on this day personally appeared FHar aJL1 2 . Kart, known to me to be the person whose name is subscribed to the foregoing instrument as pp, 61 1 tt 6hi of Baltem Development Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the / day of , 2004. LINDA M. WARREN St Chorine Count' My Commission Expires July 20, 2005 ti �� !! Notary Public Signature State of . THE STATE OF �i ¢fit eZ, § COUNTY OF .4. .4 e.0 ' § BEFORE ME, the undersigned authority, on this day personally appeared TNDnAS K CMOs known to me to be the person whose name is subscribed to the foregoing instrument as Mei:Sib6rii of Barget Development Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the f f day of Vos r , 2004. LINDA M. WARREN SI. Charles County My Commission Expkes July 20,2005 Notary Public Signature State of `73]o i • • THE STATE OF 2'/J/ § COUNTY OF BEFORE ME, the undersigned authority, on this day personally appeared Ktrtat F k • 047.Fbr4, known to me to be the person whose name is subscribed to the foregoing instrument as ('RF111) 6N1 of Karjoy Development Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the ift day of Nmi , 2004. LINDA M. WARREN 51 Charles County My Commission Expires July 20, 2005 THE STATE OF § COUNTY OF a4. 4 § BEFORE ME, the undersigned authority, on this day personally appeared TMDHhS P. GK64J. known to me to be the person whose name is subscribed to the foregoing instrument as fl.GID plc of Maxland Development Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the i d ay of 14 V. , 2004. LINDA M. WARREN 5t. Charles Ca0nly Sy Commission Expires Jury 20, 2005 Notary Public Signature State of 'Mt dit. - kV PMI Notary Public Signature State of p) , • THE STATE OF 71jj44&aI4. § COUNTY OF 4 . .4p. § BEFORE ME, the undersigned authority, on this day personally appeared T ot-!AS (.. GR known to me to be the person whose name is subscribed to the foregoing instrument as Gs KNIT ofJopat Building Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the day of Aith✓. , 2004. LINDA M. WARREN St. Charles County My Commission Expires July 20, 2005 1 79/ 12A.4 Notary Public Signature State of 7t7 THE STATE OF7iligkikin§ COUNTY OF f . L 4(II,Q/ § BEFORE ME, the undersigned authority, on this day personally appeared Tl k1MA5 R af , known to me to be the person whose name is subscribed to the foregoing instrument as Qp FS►p6NT ofNatural Bridge Development Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the / e l day of MIA , 2004. LINDA M. WARREN St. Charles County My Commission Expires July 20, 2005 _ , Notary Publi Signature State of • • THE STATE OF k LINDA M. WARREN St Charles County My Commission Expires July 20, 2005 41u § COUNTY OF . AV,td § BEFORE ME, the undersigned authority, on this day personally appeared 11koo R. C•RC-t` i known to me to be the person whose name is subscribed to the foregoing instrument as QRe,51Dgwl of Pajia Realty Corporation Corporation, A Missouri Corporation, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the /R day of Np✓. , 2004. /X LINDA M. WARREN SL Charles Coo* My CommJsslon Expires July 20, 2005 Notary Public Signature State of MO THE STATE OF 16124)§ COUNTY OF d7 . /4 § BEFORE ME, the undersigned authority, on this day personally appeared mitta is b . IiFNn1At, known to me to be the person whose name is subscribed to the foregoing instrument as M4rlA,G6R of Third Creek L.L.C., A Missouri limited liability partnership, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVE UNDER MY HAND AND SEAL OF OFFICE, this the / J day of V. 2004. Notary Public Signature State of Pp 0I At/. 8a'4) *fain • THE STATE OF fJ ) ( 4M&A,G § COUNTY OF h, 404,4/.:4- § BEFORE ME, the undersigned authority, on this day personally appeared [}aDhAS IL, GRf,& known to me to be the person whose name is subscribed to the foregoing instrument as PPM 6R of Delmar Properties, A Missouri general partnership, and he acknowledged to me that he executed the same for the purposes and considerations therein expressed, in the capacity therein stated. GIVE UNDER MY HAND AND SEAL OF OFFICE, this the /. day of y. , 2004. LINDA M. WARREN St. Chaffee County My Commission Expires July 20, 2005 FILED AND RECORDED OFFICIAL PUBLIC RECORDS 2004093328 12/03/2004 10:11 AM CARRILLO $32.00 NANCY E. RISTER, COUNTY CLERK WILLIAMSON COUNTY, TEXAS 7TH' Notary Public Signature State of Pin WHEREAS, an application has been made to the City Council of the City of Round Rock, Texas to amend the Official Zoning Map to zone 58.142 acres of land, and to rezone 54.65 acres of land out of the J.M. Harrell Survey, Abstract 284, in Round Rock, Williamson County, Texas, being more fully described in Exhibit "A ", attached hereto and incorporated herein, from District C -1 (General Commercial) to Planned Unit Development (PUD) No. 38, and WHEREAS, the City Council has submitted the requested change in the Official Zoning Map to the Planning and Zoning Commission for its recommendation and report, and WHEREAS, the Planning and Zoning Commission held a public ORDINANCE NO. z99- 0Q45 _ 1a/33 AN ORDINANCE AMENDING THE OFFICIAL ZONING MAP OF THE CITY OF ROUND ROCK, TEXAS ADOPTED IN SECTION 11.305(2), CODE OF ORDINANCES (1995 EDITION), CITY OF ROUND ROCK, TEXAS, AND MAKING THIS AMENDMENT A PART OF THE SAID OFFICIAL ZONING MAP, TO WIT: TO ZONE 58.142 ACRES OF LAND AND TO REZONE 54.65 ACRES OF LAND OUT OF THE J.M. HARRELL SURVEY, ABSTRACT 284, IN ROUND ROCK, WILLIAMSON COUNTY, TEXAS, FROM DISTRICT C -1 (GENERAL COMMERCIAL) TO PLANNED UNIT DEVELOPMENT (PUD) NO. 38. hearing concerning the requested change on the 17th day of February, 1999, following lawful publication of the notice of said public hearing, and WHEREAS, after considering the public testimony received at such hearing, the Planning and Zoning Commission has recommended that the Official Zoning Map be amended so that the property described in Exhibit "A" be zoned as Planned Unit Development (PUD) No. 38, and N:\ WPDOCS \OFDINANC \O90225B3.NPD/5C9 WHEREAS, on the 25th day of February, 1999, after proper notification, the City Council held a public hearing on the requested amendment, and WHEREAS, the City Council determines that the zoning provided for herein promotes the health, safety, morals and protects and preserves the general welfare of the community, and WHEREAS, each and every requirement set forth in Chapter 211, Sub - Chapter A., Texas Local Government Code, and Section 11.300, Code of Ordinances (1995 Edition), City of Round Rock, Texas concerning public notices, hearings, and other procedural matters has been fully complied with, Now Therefore BE IT ORDAINED BY THE COUNCIL OF THE CITY OF ROUND ROCK, TEXAS, THAT: I. That the Official Zoning Map adopted in Section 11.305(2), Code of Ordinances (1995 Edition), City of Round Rock, Texas, is hereby amended so that the zoning classification of the property described in Exhibit "A" is hereafter designated as Planned Unit Development (PUD) No. 38. II. A. All ordinances, parts of ordinances, or resolutions in conflict herewith are expressly repealed. B. The invalidity of any section or provision of this ordinance shall not invalidate other sections or provisions thereof. 2. C. The City Council hereby finds and declares that written notice of the date, hour, place and subject of the meeting at which this Ordinance was adopted was posted and that such meeting was open to the public as required by law at all times during which this Ordinance and the subject matter hereof were discussed, considered and formally acted upon, all as required by the Open Meetings Act, Chapter 551, Texas Government Code, as amended, and the Act. Alternative 1. By motion duly made, seconded and passed with an affirmative vote of all the Council members present, the requirement for reading this ordinance on two separate days was dispensed with. READ, PASSED, and ADOPTED on first reading this cQ5 day of 1999. Alternative 2. READ and APPROVED on first reading this the day of , 1999. READ, APPROVED and ADOPTED on second reading this the day of , 1999. ATTEST: a t JL E LAND, City Secretary CHARLES CULPEPP'R, M•yor City of Round Rock, Texas 3. List of Exhibits 1. Exhibit A: Property Description page 5 2. Exhibit B: Agreement and Development Plan page 18 3. Exhibit C: Lienholder Consent page 26 4. Exhibit D: Permitted Uses and Limitations page 27 5. Exhibit E: Project Identification Sign Locations page 33 6. Exhibit F: Combination and Monument Sign Locations page 34 7. Exhibit G: Utility Schematic and Drainage Plan page 35 8. Exhibit H: Roadway Light Fixtures page 36 9. Exhibit I: Permitted Outdoor Sales Area page 37 10. Exhibit J: Sidewalk Locations page 38 11. Exhibit K: Parking Lot and Walkway Light Fixtures page 39 12. Exhibit L: Traffic Impact Analysis page 41 F:\malbas\080000164:apud -oo-e 004 La Frantera East - PUD No. 38 Ordinance Page 4 -4- Tract I: Parcel A: A 40 acre tract of land being Lot 1, Block "A ", La Frontera Section I, a subdivision in the city of Round Rock, Williamson County, Texas, according to the map or plat thereof recorded in Cabinet Q, Slides 203, 204 and 205 of the Plat Records of Williamson County, Texas, being described by metes and bounds on Exhibit A -1 attached hereto. Tract II: A 58.142 acre tract of land more fully described on Exhibit A -3 attached hereto. La Frontera East - PUD No. 38 Property Description Page 1 of 2 EXHIBIT A PROPERTY DESCRIPTION OF 112.766 ACRES OF LAND Parcel B: A 14.625 acre tract of land more fully described on Exhibit A -2 attached hereto. -5- Ni anO Tan9Uma 3.256 Ac. 8 .172 yr01 BLM SKETCH TO ACCOMPANY DESCRIPTION r ' City of £o.- f Round Rock w °$ y % Ridyehill Inv,Q Chisholm Volley South Cr p4� N P 2.128 Acres Sec. 10 RssuD. etc Lot ,1 BI. A. Result. \it # / Chisholm Valle f South th Section Frye et . \ Acres 4 6 Norfhrldge Q :4 Acres L imeclo R APm is• Tom E N4l�on 9.517 r$e. Tom E. Nelson 9.80 Ac. DATE: December, 199B JOB No.: 352 - 703 -51 BY M. Nolen � SCALE: 1" = 1000' a f Holding Co. FTract'Sce. 1 11.108- Ac. POINT OF BEGINNING Lo IA. �I Amt ends of Corners North Lot BJ.A Amended Plot Corners North 8 c Associates, Inc. Engineers/Surv•yors File nom: M:\tdAR81E\35E \PUD Plot dots: 12/18/90 40.000 Acre Trey Page lof 2 LA FRONTERA SECTION I DESCRIPTION FOR A 40.000 ACRE TRACT OF LAND SITUATED IN THE J. M. HARRE.LL SURVEY, ABSTRACT NO. 284, IN WILLIAMSON COUNTY, TEXAS, BEING ALL OF LA FRONTERA SECTION I, A SUBDIVISION RECORDED IN CABINET Q, SLIDES 203 -205 OF THE PLAT RECORDS OF SAID COUNTY, SAID 40.000 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING on an iron found on the southeasterly corner of said Lot 1, same being a point in the westerly right -of -way of Interstate Highway No. 35 (right -of -way width varies), same being a point in the easterly boundary line of a 227.8382 acre tract as conveyed by instrument recorded as Document No. 9848753 of the Official Records of said County, said point also being a southeasterly corner and POINT OF BEGINNING hereof; THENCE with the southerly boundary line of said Lot 1, the following four (4) courses and distances: 1) S 86° 58' 29" W for a distance of 192.73 feet to an iron rod found on an angle point hereof; 2) S 86° 54' 05 W for a distance of 112.97 feet to an iron rod found on an angle point hereof; 3) S 14° 05' 19" E for a distance of 47.87 feet to an iron rod found on an angle point hereof; 4) S 86° 55' 00" W (Bearing Basis/Directional Control Line) for a distance of 1519.30 feet to an iron rod found on the southwesterly corner hereof; THENCE with the westerly boundary line of said Lot 1, N 15° 00' 21" E for a distance of 1244.48 feet to an iron rod found on the northwesterly corner of said Lot 1, said point being the northwesterly comer hereof; THENCE with the northerly boundary line of said Lot 1, La Frontera Section I, same being a northerly boundary line of said 227.8382 Acre Tract, also being in part with the southerly boundary line of Lot 1, Block A, Chisholm Valley South Section Five, a subdivision as recorded in Cabinet 0, Slide 178 of said Plat Records, the following three (3) courses and distances: EXIBBTr A _ Page / of 3 -7- 40.000 Acre Tract Page 2of 2 1) N 87° 45' 45" E for a distance of 122.11 feet to an angle point hereof; 2) N 02° 14' 15" W for a distance of 4.72 feet to an angle point hereof; 3) N 88° 02' 13" E for a distance of 1006.09 feet to an iron rod found on the northeasterly corner of said Lot 1, La Frontera Section I, same being the southeasterly corner of said Lot 1, Chishohn Valley South Section Five, same being a point in the westerly right -of -way line of said Interstate Highway No. 35, being the northeasterly corner hereof, THENCE with the westerly right -of -way line of said Interstate Highway No. 35, same being with the easterly boundary line of said Lot 1, La Frontera Section I, also being the easterly boundary line of said 227.8382 Acre Tract, the following three (3) courses and distances: 1. S 20° 33' 51" E for a distance of 720.67 feet to an angle point hereof; 2. S 18° 53' 51" E for a distance of 12.71 feet to a concrete monument found, being on angle point hereof; 3. S 14° 03' 46" E for a distance of 427.60 feet to the POINT OF BEGINNING hereof and containing 40.000 acres of land. Surveyed under the direct supervis n of the undersigned: /#14;(10(04—■• Z ' e f - ql Cecil J .n Chisholm Regist Professional Land Surveyor No. 4295 BAKER AICKLEN & ASSOCIATES, INC. 203 E. Main Street, Suite 201 Round Rock, Texas 78664 (512) 244-9620 Job No.: 352-703-23 File Name: M:IMARGIE1352703\MB PUD -LAF1 EXHIBIT Page Z of 3 Dated -8- SKETCH TO ACCOMPANY DESCRIPTION £Roun Rock a u N Ridgehlll Inv ° o , 2.128 Acres m • W, Chisholm Volley South CtosS Sea. 10 Resta,. t ele / Lot l 81. A Reeve. e8 S outh Sectionl ve etlon Cem. DATE: December, 1998 JOB No.: 352 - 703 -51 BY: M. Nolen SCALE: 1' = 1000' Amended l Pldt Corners North \ Amended Plot Corners North F 7r 7 0e1 t Seoul Baker— Aicklen & Associates, Inc. Engineers /Surveyors Fil name: M: \MARGIE \352 \PUD PI I Ante: I /P4 /P? 14.625 Acre Tract Page 1 of 2 P.U.D. — 14.625 ACRES DESCRIPTION FOR A 14.625 ACRE TRACT OF LAND SITUATED IN THE J. M. HARRELL SURVEY, ABSTRACT NO. 284, IN WII LIAMSON COUNTY, TEXAS, BEING ALL OF A 14.625 ACRE TRACT CONVEYED TO D.D.R. DB DEVELOPMENT BY INSTRUMENT RECORDED AS DOCUMENT NO. 9844186 OF THE OFFICIAL RECORDS OF SAID COUNTY, SAID 14.625 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING on an iron rod found on the southeasterly corner of said 14.625 Acre Tract, same being a point in the northerly right - of-way line of F. M. Highway No. 1325 (120' right-of-way width), said point being the southeasterly corner and POINT OF BEGINNING hereof; THENCE with the southerly boundary line of said 14.625 Acre Tract, same being the northerly right -of -way line of said F. M. Highway No. 1325, S 86° 56' 50" W for a distance of 403.67 feet to an iron rod found on the southwesterly corner of said 14.625 Acre Tract, same being a southeasterly comer of a 227.8382 acre tract as conveyed by instrument recorded as Document No. 9848753, same being the southwesterly corner hereof; THENCE departing said F. M. Highway No. 1325, with the westerly boundary line of said 14.625 Acre Tract, same with the easterly boundary line of said 227.8382 Acre Tract, N 14° 05' 56" W for a distance of 1120.51 feet to an iron rod found on the northwesterly comer of said 14.625 Acre Tract, same being an angle point of said 227.8382 Acre Tract, same being the northwesterly corner hereof, THENCE with the northerly boundary line of said 14.625 Acre Tract, same being a southerly boundary line of 227.8382 Acre Tract, N 86° 55' 10" E (Bearing Basis/Directional Control Line) for a distance of 709.06 feet to an iron rod found on the northeasterly corner of said 14.625 Acre Tract, same being the northwesterly corner of Lot 1, Town & Country Mall Subdivision, a subdivision as recorded in Cabinet L, Slide 57, of the Plat Records of said County, same being the northeasterly corner hereof; THENCE with the westerly boundary line of said Lot 1, Town & Country Mall Subdivision , same being with an easterly boundary line of said 14.625 Acre Tract, S 03' 04' 58" E for a distance of 824.88 feet to an iron rod found on an angle point of said'14.625 Acre Tract, same being the southwesterly corner of said Lot 1, Town & Codntry Mall Subdivision, same being an angle point hereof; EXHIBIT-g-- Page_ of 3 -10- 14.625 Acre Tract Page 2 of 2 THENCE with a southerly boundary line of said 14.625 Acre Tract, S 86° 51' 56" W for a distance of 91.29 feet to an iron rod found on an angle point of said 14.625 Acre Tract, same being an angle point hereof; THENCE with an easterly boundary line of said 14.625 Acre Tract, S 03° 05' 06" E for a distance of 275.08 feet to the POINT OF BEGINNING hereof and containing 14.625 acres of land. Surveyed under the direct supervision of the undersigned: Cecil Ja on Chisholm Registe i Professional Land Surveyor No. 4295 BAKER- AICKLEN & ASSOCIATES, INC. 203 E. Main Street, Suite 201 Round Rock, Texas 78664 (512) 244-9620 Dated Job No.: 352 -703 -23 File Name: M:IMARQE13527031MB -PUD- CAPPS.doc EXHIBTT /_ Page 2 of 3 _ -9 ? Nisano Ton uma 3.258 Ac. a :172 At M o ey ed rt ra9 4 11 SKETCH TO ACCOMPANY DESCRIPTION e Northridge Acres Northridge Acres Chisholm Volley South L , v o9e� 9Qa Sec. ID Resub. tg Lot 1' BI. A, Resub, e5t Ch'sholm ValleyY \/� Soul Setllon Flve allon Cem. Limestone Ridge Ap Tom E. Nelson 9.317 Ac. DATE: December, 1998 JOB No.: 352- 703 -5 BY: M. Nolen Farmers Insur• Holding Co. Trocl Sec. 1 11.108 Ac. SCALE: 1' = 1000' iP Ldf IA BI• men ed PloA l Corners North A Plat Corners North Baker— Aicklen & Associates, Inc. EngineerEngtneer- eYcrs FII name; M: \MARGIE \ 352703 \PUD PI t date: 1/29/99 Page 1 of 4 58.142 Acre Tract DESCRIPTION FOR A 58.142 ACRE TRACT OF LAND SITUATED IN THE I. M. HARRELL SURVEY, ABSTRACT NO. 284, SITUATED IN WIl LIAMSON COUNTY, TEXAS, BEING A PORTION OF A 227.8382 ACRE TRACT OF LAND CONVEYED TO 35/45 INVESTORS, L.P., A TEXAS PARTNERSHIP, BY INSTRUMENT RECORDED AS DOCUMENT NO. 9848753 OF THE OFFICAL RECORDS OF SAID COUNTY, SAID 58.142 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING on an iron rod found on a southeast corner of said 227.8382 acre tract, same being a point in the west right -of -way line of Interstate Highway No. 35 (right -of- way varies), same being the northeast comer of Lot 1, Block A, Resubdivision of Lot I, Block A, Corners North a subdivision according to the plat thereof recorded in Cabinet I, Slide 118, of the Plat Records of said County, said point being the most easterly comer and POINT OF BEGINNING hereof, from which, a southeasterly corner of said 1. M. Harrell Survey bears approximately S 40° 16' E a distance of 470 feet; THENCE departing the west right -of -way line of said Interstate Highway No. 35, in part with the north boundary line of said Lot 1, Block A, in part with the north boundary line of Lot 1, Town & Country Mall Subdivision, a subdivision as recorded in Cabinet L, Slide 57, of the Plat Records of said County, S 86° 55' 10" W (Bearing Basis/Directional Control Line) a distance of 884.72 feet, pass an iron rod found on the northwest corner of said Lot 1, Town & Country Mall Subdivision, same being the northeast corner of a 14.625 acre tract of land as described by instrument recorded as Document No. 9844186 of said Official Records, continue on said course with the north boundary line of said 14.625 acre tract for a total distance of 1593.78 feet to an iron rod found on the northwest comer of said 14.625 acre tract, same being an angle point hereof, THENCE with the west boundary line of said 14.625 acre tract, S 14° 05' 56" E for a distance of 1120.51 feet to an iron rod found on the southwest corner of said 14.625 acre tract, same being in the north right -of -way line of F. M. Highway No. 1325 (120' right - of -way width), being a southeasterly corner hereof; THENCE with the north right -of -way line of said F. M. Highway No. 1325, S 86° 56' 50" W for a distance of 545.22 feet to an iron rod set on the southeast corner of a 0.617 acre remnant tract of land as conveyed by instrument recorded in Volume 1628, EXHIBIT I� - 3 Page 1 of .S -13- Page 2 of 4 58.142 Acre Tract Page 362, of the Official Records of said County, same being an angle point in the southerly boundary line hereof; THENCE departing the north right -of -way line of said F. M. Highway No. 1325 with the easterly, northerly, and westerly boundary line of said 0.617 acre tract the following three courses and distances: 1) N 13° 31' 33" W for a distance of 209.97 feet to an iron rod found on the northeast comer of said 0.617 acre tract, being an interior angle point hereof; 2) S 86° 52' 19" W for a distance of 129.90 feet to an iron rod found on the northwest comer of said 0.617 acre tract, being an interior angle point hereof; 3) S 13° 44' 29" E for a distance of 209.94 feet to an iron pipe found on a point in the north right -of -way line of said F. M. Highway No. 1325, same being the southwest corner of said 0.617 acre tract, being an angle point in the southerly boundary line hereof; THENCE with the north right-of-way line of said F. M. Highway No. 1325, S 86° 56' 50"W for a distance of 58.50 feet to a concrete monument found on a point of curvature hereof THENCE with the arc of the curving right -of -way line of said F. M. Highway No. 1325 to the left, having a radius of 1014.88 feet, a central angle of 14° 09' 02", an arc length of 250.65 feet, and a chord which bears S 79° 52' 56" W for a distance of 250.01 feet to an iron rod set on the southwest comer hereof THENCE departing the north right -of -way line of said F. M. Highway No. 1325 through the interior of said 227.8382 acre tract the following six courses and distances: 1) N 03° 03' 10" W fora distance of 356.15 feet to an iron rod set on a point of curvature hereof; 2) with the arc of a curve to the left, having a radius of 1040.00 feet, a central angle of 17° 27' 48 ", an arc length of 316.98 feet, and a chord which bears N 11° 47' 04" W for a distance of 315.76 feet to an iron rod set on a point of tangency hereof; 3) N 20° 30' 58" W fora distance of 1135.10 feet to an iron rod set on a point of ;curvature hereof; EXHIBIT 4 -3 Page 2 of s -14- Page 3 of 4 58.142 Acre Tract 4) with the arc of a curve to the left, having a radius of 1040.00 feet, a central angle of 16° 03' 48 ", an arc length of 291.57 feet, and a chord which bears N 28° 32' 52" W for a distance of 290.62 feet to an iron rod set on a point of tangency hereof; 5) N 36° 34' 46" W for a distance of 73.94 feet to an iron rod set on a curving arc hereof; 6) with the arc of a curve to the left, having a radius of 1000.00 feet, a central angle of 11° 11' 15 ", an arc length of 195.26 feet, and a chord which bears N 45° 32' 03" E for a distance of 194.95 feet to an iron rod set on a point of tangency hereof; 7) N 39° 56' 26" E for a distance of 109.62 feet to an iron rod set on a point of curvature hereof; 8) with the arc of a curve to the right, having a radius of 950.00 feet, a central angle of 14° 03' 57 ", an arc length of 23322 feet, and a chord which bears N 46° 58' 24" E for a distance of 232.63 feet to an iron rod set on a point in the west boundary line of a 2.128 acre tract of land as described by instrument recorded as Document No. 9875537, of the Official Records of said County, same being in the northerly boundary line of said 227.8382 acre tract, same being an angle point in the northerly boundary line hereof; THENCE with the west boundary line of said 2.128 acre tract, same being the northerly boundary line of said 227.8382 acre tract, S 14° 20' 19" E for a distance of 12.21 feet to an iron rod found on the southwest corner of said 2.128 acre tract, being also an angle point in the northerly boundary line of said 227.8382 acre tract, being also an angle point in the northerly boundary line hereof; THENCE with the northerly boundary line of said 227.8382 acre tract of land, N 87° 45' 45" E for a distance of 1055.76 feet to an iron rod found on a point being the northwesterly comer of a 40.000 acre tract of land known as Lot 1, Block A, La Frontera, Section 1, a subdivision according to the plat thereof recorded in Plat Cabinet Q, Slides 203 -205 of said Plat Records, said point being a northeasterly corner hereof; THENCE with the west and south boundary line of said La Frontera Section I, the following five courses and distances: 1) S 15° 00' 21" W for a distance of 1244.48 feet to-an iron rod found on the southwest corner of said La Frontera Section I, being an interior corner hereof; EXHIBrr - Page_ of -15- Page 4 of 4 58.142 Acre Tract 2) N 86° 55' 00" E for a distance of 1519.30 feet to an iron rod found on an interior corner hereof; 3) N 14° 05' 19" W for a distance of 47.87 feet to an iron rod found on an angle point hereof; 4) N 86° 54' 05" E for a distance of 112.97 feet to an iron rod found on an angle point hereof, 5) N 86° 58' 29" E fora distance of 192.73 feet to an iron rod found on a point in the west right -of -way line of said Interstate Highway No. 35, said point being a northeasterly comer hereof THENCE with the west right-of-way line of said Interstate Highway No. 35, S 14° 03' 46" E for a distance of 142.54 feet to the POINT OF BEGINNING hereof and containing 58.142 acres of land. Surveyed der the direct supervision of the undersigned: ilia Cecil ' - • . n Chisholm Regi - .. Professional Land Surveyor No. 4295 B 4 :I+ - AICKLEN & ASSOCIATES, INC. 203 '! Street, Suite 201 Round Rock, Texas 78664 (512) 244-9620 Job No.: 352-703-23 File Name: M:IMARGIE13527031MB- LaF2.doc ExHiBIT A - 3 Page 4 of -16- Nisano Tanguma 3.258 Ac. B:172 Ac. propos state 1 0018. A SKETCH TO ACCOMPANY DESCRIPTION 35/45 Investors, L. P, 227.8382 Acres NoAcr figs I o r Northridge 4,ae A cres g. i' Round Rock 4 0 South Cf 9`' N o p S Ridgehlll Inv.R Chisholm Valley 0 2,128 Acres ,. Sec. 10 Resub, es Lot I, BI. A, Resat). o w VB South Section Five o at ton Cem. DI�ime ato mt s Rldgs AP Tom E Nelson 9.317 Ac. Tom E. Nakao 9.80 Ac. Holding Co. 11.108 Ac. DATE: December, 1998 JOB No,: 352 - 703 -5 BY: M. Nolen 1e, SCALE: 1' = 1000' Amends 'Pitt Corners Loh Lot l B1. A Amended Plot Corners North F Troat s Secu r. POINT OF BEGINNING 58.142 ACRES Baker— Alcklen Sc Associates, Inc. Engineers /Surveyors File name: M: \MARGIE \35 \ PUD PI t date: 1/29/99 AGREEMENT AND DEVELOPMENT PLAN FOR LA FRONTERA EAST PLANNED UNIT DEVELOPMENT NO. 38 THE STATE OF TEXAS COUNTY OF WI LLIAMSON EXHIBIT B THIS AGREEMENT AND DEVELOPMENT PLAN (this "Agreement ") is made and entered by and between the City of Round Rock, Texas, a Texas municipal corporation, having its offices at 221 East Main Street, Round Rock, Texas 78664 (hereinafter referred to as the "City"), and 35/45 Investors, L.P. and DDR DB Development Ventures LP, (hereinafter collectively referred to as the "Owner "). WHEREAS, the Owner has submitted a request to the City to zone approximately 112.766 acres of land as a Planned Unit Development ( "PUD "), said property being more particularly described in Exhibit "A" ( hereinafter referred to as the "Property"), and WHEREAS, pursuant to Chapter 11, Section 11.316(8), Code of Ordinances (1995 Edition), City of Round Rock, Texas, the Owner has submitted a development plan setting forth the development conditions and requirements within the PUD (the "Development Plan "), which Development Plan is contained in Section II of this Agreement; and WHEREAS, on abeuAiey /7 , 1999, the City's Planning and Zoning Commission recommended approval of the Owner's application for a PUD. NOW THEREFORE BY THIS AGREEMENT WITNESSETH that, in consideration of the covenants and conditions set forth herein, the City and the Owner agree as follows: L GENERAL PROVISIONS 1. CONFORMITY WITH DEVELOPMENT PLAN All uses and development within the Property shall generally conform to the Development Plan set forth in Section II herein. La Frontera East - PUD No. 38 Agreement and Development Plan Page 1 -18- 2. CHANGES AND MODIFICATIONS No changes or modifications will be made to this Agreement or the Development Plan unless all provisions pertaining to changes or modifications as stated in Article III, Section 1 below are followed. 3. ZONING VIOLATION The Owner understands that any person, firm, corporation or other entity violating any conditions or terms of the Development Plan shall be subject to any and all penalties for the violation of any zoning ordinance as stated in Section 1.601, Code of Ordinances, (1995 Edition), City of Round Rock, Texas, as amended. 4. LIENHOLDER CONSENT There is no outstanding debt secured by the Property and no lienholder of record. A lienholder consent is not required. 5. MISCELLANEOUS PROVISIONS 5.1 Assignment. Neither party may assign its rights and obligations under this Agreement without having first obtained the prior written consent of the other which consent shall not be unreasonably withheld. This section shall not prevent the Owner from conveying the Property or portions of the Property, together with all development rights and obligations contained in this Agreement. 5.2 Necessary Documents and Actions. Each party agrees to execute and deliver all such other and further instruments and undertake such actions as are or may become necessary or convenient to effectuate the purposes and intent of this Agreement. 5.3 Severability. In case any one or more provisions contained herein are deemed invalid, illegal or unenforceable in any respect, such invalidity, illegality or unenforceability shall not affect any other provisions hereof and in such event, this Agreement shall be construed as if such invalid, illegal or unenforceable provision had never been contained herein. La Frontera East - PUD No. 38 Agreement and Development Plan Page 2 -19- 5.4 Entire Agreement. This Agreement constitutes the entire agreement of the parties and supersedes any prior or contemporaneous oral or written understandings or representations of the parties respecting the subject matter hereof. 5.5 Applicable Law. This Agreement shall be construed under and in accordance with the laws of the State of Texas. 5.6 Venue. All obligations of the parties created hereunder are performable in Williamson County, Texas and venue for any action arising hereunder shall be in Williamson County. 5.7 No Third Party Beneficiaries. Nothing in this Agreement, express or implied, is intended to confer upon any person or entity, other than the parties hereto (and their respective successors and assigns) any rights, benefits or remedies under or by reason of this Agreement 5.8 Duplicate Originals. This Agreement may be executed in duplicate originals, each of equal dignity. 5.9 Notices. Until changed by written notice thereof any notice required under this Agreement may be given to the respective parties by certified mail, postage prepaid or by hand delivery to the address of the other party shown below: OWNER 35/45 Investors, L.P. 808 West 10'" Street Austin, Texas 78701 Attn: William S. Smalling and La Frontera East - PUD No. 38 Agreement and Development Plan Page 3 DDR DB Development Ventures LP 5606 North McArthur Blvd., Suite 210 Irving, Texas 75038 Attn: David Berndt CITY OF ROUND ROCK City of Round Rock, Texas 221 East Main Street Round Rock, Texas 78664 Attn: Director of Planning -20- 5.10 Effective Date. 5.11 Binding Effect. This Agreement and the Development Plan binds and benefits the Owner and its successors and assigns. 1. DEFINITIONS 2. PROPERTY 3. PURPOSE This Agreement shall be effective from and after the date of due execution hereof by all parties. La Frontera East - PUD No. 38 Agreement and Development Plan Page 4 IL DEVELOPMENT PLAN Words and terms used herein shall have their usual force and meaning, or as defined in the Code of Ordinances (1995 Edition), City of Round Rock, Texas, hereinafter referred to as "the Code". This Development Plan ( "Plan") covers approximately 112.766 acres of land, located within the city limits of Round Rock, Texas, and more particularly described in Exhibit "A ". The purpose of this Plan is to insure a Planned Unit Development (` PUD ") that: (i) is equal to or superior to development that would occur under the standard ordinance requirements, (ii) is in harmony with the General Plan of the city of Round Rock, Texas, (iii) does not have an undue adverse affect upon adjacent property, the character of the neighborhood, traffic conditions, parking, utilities or any other matters affecting the public health, safety and welfare, (iv) is adequately provisioned by essential public facilities and services, and (v) will be developed and maintained so as to not dominate, by scale or massing of structures, the immediate neighboring properties or interfere with their development or use in accordance with any existing zoning district. 4. APPLICABILITY OF CITY ORDINANCES 4.1 Zoning and Subdivision Ordinance. The Property shall be regulated for purposes of zoning and subdivision by this Plan. All aspects not specifically covered by this Plan shall be regulated by applicable sections of the Code. -21- 4.2 Other Ordinances. All other Ordinances within the Code shall apply to the Property, except as clearly modified by this Plan. 5. DEVELOPMENT AREAS The Property will be developed as a single development area. The total land area of 112.766 acres may be developed with buildings containing a combined maximum building area of no more than 1,228,022 square feet. 6. PERMITTED USES AND LIMITATIONS The Property will be used and developed in accordance with the requirements as set forth in this Agreement and, if not set forth herein, by applicable sections in the Code. Specific permitted uses of and limitations applicable to the Property are detailed on Exhibit "D" attached hereto and incorporated herein. 7. SIGNS 7.1 Project Identification Signs: Signs for the purpose of identifying the Property (the "Project Identification Signs ") as "La Frontera" (or other development name) may be installed and maintained by Owner on the Property at the locations designated on Exhibit "E" attached hereto and incorporated herein, provided no more than one Project Identification Sign is placed at each location. The Project Identification Signs may be no more than five feet (5') high, four feet (4') deep, and twelve feet (12') wide, unless otherwise approved by the City. The Project Identification Signs may not identify any specific occupants of the Property. The Project Identification Signs must be placed in accordance with the provisions of (i) the setback and spacing requirements of Table 3.1403 of the Code, and (ii) the corner lot vision clearance requirements of Section 11.304(7) of the Code. No Project Identification Sign may be placed in any street or road right -of -way without a license agreement executed by the City. 7.2 Combination Signs: Signs for the purpose of identifying multiple occupants of the Property (the "Combination Signs") may be installed and maintained by Owner on the Property at the locations designated on Exhibit "F" attached hereto and incorporated herein, provided no more than one Combination Sign is placed at each location. The Combination Signs may be no more than forty -five feet (45') high with no more than 405 square feet of sign face on each side, provided, however the Combination Sign to be installed in the area detailed as "Interior Location" on Exhibit "F" may be of a four sided tower design not more than sixty feet (60 ") high with no more than 240 square feet of sign face on each side. The Combination Signs must be placed in accordance with the provisions of: (i) the setback and spacing requirements of Table 3.1403 of the Code, and (ii) the corner lot vision clearance requirements of Section 11.304(7) of the Code. No Combination Sign may be placed in any street or road right -of -way without a license agreement executed by the City. La Frontera East - PUD No. 38 Agreement and Development Plan Page 5 -22- 7.3 Monument Signs: Monument signs for the purpose of identifying occupants of the Property may be located as designated on Exhibit "F ". The monument signs must be constructed in accordance with the specifications contained in the Code. 8. STORMWATER FILTRATION AND DETENTION. 8.1 Drainage: Plans for drainage facilities will be reviewed and approved by the City for each portion of the Property as each such portion of the Property is subdivided. A conceptual drainage plan is included in the Utility Schematic and Drainage Plan on file in the P &CD Department, a copy of which is attached hereto as Exhibit "G" and incorporated herein. Both the utility schematic and the drainage plan that are a part of Exhibit "G" are conceptual in nature and may be modified in the future. 8.2 Stormwater Facilities: Owner, at Owner's expense will construct all stormwater, sedimentation, filtration and/or detention ponds (the "Stormwater Ponds ") necessary to serve: (i) the public roads on the Property and (ii) the lots or other parcels of the Property. Owner may construct regional Stormwater Ponds serving multiple lots or road segments to fulfill Owner's obligations under this Section 8.2. Owner may delegate Owner's responsibility for construction and maintenance of the Stormwater Ponds to: (i) purchasers of lots or other parcels of the Property, or (ii) a separate entity created for such purpose. 9. ROADWAYS/TRAFFIC Development of the Property will be generally in accordance with the Traffic Impact Analysis attached hereto as Exhibit "L" and incorporated herein. Minor modifications may be made to the roadway plans by agreement between the Director of Public Works and Owner. 9.1 Road Construction: The following conditions concerning roads on the Property must be fulfilled before any building permit will be issued by the City for any lot that is a part of the Property: a. Road construction plans for Parker Avenue and Sundance Parkway east of Kouri Avenue (collectively, the "Roads") have been approved by the City (the "Approved Plans "). b. Fiscal security for the construction of the Roads has been posted in accordance with the Code or construction of the Roads has been completed in accordance with the Approved Plans. 9.2 Light Fixtures: In connection with the construction of the roads, street light fixtures will be installed in accordance with the design shown on Exhibit "11" attached hereto and incorporated herein and conforming with the following specifications: a. The light fixture will be black or dark bronze in color and of a horizontal design with sharp cutoff edges. La Frontera East - PUD No. 38 Agreement and Development Plan Page 6 -23- 11. RESTRICTIONS b. The illumination source will be metal halide (or equivalent). c. The light fixture will be mounted on a metal pole. The pole will be the same color as the light fixture. 10. PHASED DEVELOPMENT The Owner has the option to develop the Property as a phased development. The Property may be platted into two or more lots to accommodate phasing. The Property will be developed in accordance with any conditions, covenants or restrictions of record with the Williamson County Clerk. HI MISCELLANEOUS PROVISIONS 1. CHANGES TO DEVELOPMENT PLAN 1.1 Minor Changes. Minor changes to this Agreement or the Development Plan which do not substantially change this Agreement or the Development Plan may be approved administratively, if approved in writing, by the Director of Public Works, the Director of Planning and Community Development, and the City Attorney. 1.2 Major Changes. Major changes to this Agreement or the Development Plan must be resubmitted following the same procedure required by the original PUD application. 2. GENERAL PLAN AMENDED The Round Rock General Plan is hereby amended to reflect the provisions of this Agreement and Development Plan. La Frontera East - PUD No. 38 Agreement and Development Plan Page 7 CITY OF, ' OUND ROCK, TEXAS Charles Culpe p r, Mayor City of Round Rock, Texas Date: ,9 -A5 , 1999 F: 1RA4 P .LBERSW8000016\PUDIORD&PL -E.007 La Frontera East - PUD No. 38 Agreement and Development Plan Page 8 35/45 INVESTORS, L.P. By: 35/45 Genpar, L.L.C. By: Date://i1A4 3.I , 199& DDR DB DEVELOPMENT VENTURES LP By: DDR DB Opportunity Sub, Inc. By: Name: Title: Date: , 199_ -25- CITY OF ROUND ROCK, TEXAS 35/45 INVESTORS, L.P. By: 35/45 Genpar, L.L.C. By: Charles Culpepper, Mayor City of Round Rock, Texas Date: , 199 F:t RMALBERS ■080000166PUDtORD&PL.E. La Frontera East - PUD No. 38 Agreement and Development Plan Page 8 By: W d liam S. Smalling, Manager Date: ,199 DDR DB DEVELOPMENT VENTURES LP By: DDR DB Opportunity Sub, Inc. By: 11 Name: TOadt Title: V , a OrA< Date: 3 LI 6 .1991 -25- La Frontera East - PUD No. 38 Lienholder Consent Page 1 of 1 EXHIBIT C LIENHOLDER CONSENT NO LIENHOLDER NO LIENHOLDER CONSENT REQUIRED -26- Permitted Use* Building Height Limitation ** Building Setbacks from: Hester's Crossing Kouri Avenue Sundance Parkway Other Roads General Commercial (C -1) 45 feet 60 feet 25 feet 25 feet 25 feet Shopping Center 45 feet 60 feet 25 feet 25 feet 25 feet Restaurant*** 45 feet 60 feet 25 feet 25 feet 25 feet Cinema 65 feet 60 feet 25 feet 25 feet 25 feet Office 45 feet 60 feet 25 feet 25 feet 25 feet ** rss 2. Prohibited Uses. 3. Outdoor Sales and Displays. La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 1 EXHIBIT D PERMITTED USES AND LIMITATIONS APPLICABLE TO THE PROPERTY The permitted uses and limitations applicable to the Property are as follows: 1. Permitted Uses, Heights and Setbacks. Permitted uses, building height limitations, building setbacks and landscaping setbacks are detailed in the chart below: Zoning designations noted in parentheses indicate all uses permissible under the Code for such designation as of the date of this Ordinance. Such uses may include, but are not limited to, other uses also listed in this chart Limitations for any specific C -1 use listed in this chart will control over the general C -1 listing. Decorative architectural features may exceed the stated height limitation by 15 feet except that decorative architectural features in connection with a cinema may exceed the stated height limitation by 30 feet. Including bar and liquor sales. The following uses are prohibited on the Property: mini- warehouses, flea markets, sexually oriented businesses (as defined in the Code), amusement parks or carnivals, portable building sales except as incidental to other retail sales, recreational vehicle parks, wholesale nurseries, outdoor shooting ranges, pawn shops, heavy equipment sales, kennels (but not prohibiting pet shops and veterinary clinics with overnight facilities), vehicle sales and truck stops. Outdoor sales and displays are permitted in conjunction with the use of a building only in areas designated on the site plan filed with the City for such building. Outdoor sales and displays are further limited to the following areas: -27- a. Sidewalks: on sidewalks adjacent to buildings, but limited to an area of no more than thirty percent (30%) of the sidewalk area that is located within twenty feet (20) from the building. In no event may the sidewalk sale and display area exceed five percent (5 %) of the interior floor area of the adjoining building. b. Dining: any outdoor cafe or outdoor dining area (including outdoor seating for a food court) that: (i) is located and operated as an integral part of the principal use, and (ii) does not comprise a separate business use or a separate business activity. Parking requirements contained in the Code will apply to all outdoor cafes and dining areas in the same manner that such requirements apply to enclosed buildings. c. Permitted Outdoor Sales Area: one area that is: (i) located as detailed in Exhibit "1°" attached hereto and incorporated herein, but not more than 150 feet from the principal building that it serves, (ii) not greater than 10,000 square feet in size, and (w) visually screened with a permanent landscape screen on all sides, except for the side facing the principal building that it serves. The landscape screen must be irrigated and of sufficient density to block views of the majority of the interior of the Permitted Outdoor Sales Area from ground level. The permitted outdoor sales area must be an area separate from (not a part of) any parking lots, however the permitted outdoor sales area may be adjacent to or surrounded by parking lots. The permitted outdoor sales area may not impede traffic circulation. 4. Buildings. a. Prohibited Materials: The following materials are prohibited on the exterior walls of all buildings and structures (this section does not apply to roofs): Sheet, corrugated, and unfinished Aluminum Asbestos Galvanized Steel Mirrored Glass (reflectivity of 20% or more) b. Building Elevations and Rooflines: To avoid the design of a continuous, unbroken wall facade and a continuous roofline (big box design), structures over 200 feet in length must be designed so as to stagger the front facades and rooflines to break up the visual expanse of the structures. 5. Sidewalks. All sidewalks will be located within the sidewalk zone as shown in the Traffic Impact Analysis attached hereto as Exhibit "L" and incorporated herein. One of the following is required along all public roads (except Farm to Market Road 1325): Standard Sidewalks: Sidewalks at least 5 feet wide on both sides of the road as detailed on Exhibit "J" attached hereto and incorporated herein. La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 2 -28- b. Wide Sidewalk A sidewalk at least 8 feet wide on one side of the road as detailed on Exhibit "J". 6. Outdoor Storage, Service and Loading Areas. a. Screening Required: No outside storage or dock high loading area is permitted unless such area is visually screened from public view. b. Delivery Vehicles: All delivery and utility vehicles stored on -site must be inside a closed building or within a screened portion of the site. c. Service Areas: Service areas will be screened from adjacent tracts and all public rights -of -way. Methods of screening include walled entrances, evergreen landscaping, and depressed service areas. Screening walls must be constructed of the same materials as the main building. d. Loading Areas: All loading and service areas must be clearly signed. Loading spaces must be clearly denoted on the pavement and designed so as to not prohibit on -site vehicular circulation when occupied. Loading spaces will be located directly in front of a loading door. Loading areas must be designed to accommodate backing and maneuvering on -site, not from a public street. Regardless of orientation, loading doors may not be located closer than fifty feet (50') from a public or private right -of- way. e. Trash Storage: Refuse storage enclosures are required for all buildings. Enclosures must be of sufficient height to screen all refuse containers completely and must be provided with gates, so as to provide screening of views from adjacent lots and public rights -of -way. All enclosures must be constructed of permanent materials (concrete, masonry, wood, steel, etc.) which are compatible with the building it serves. Refuse storage areas must be designed to contain all refuse generated on -site between collections. (refer to figure 1) La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 3 figure 1 SCREEN TRASH AREA FRCP WIC•RISE VIEWS SERVICE COURT SCREEN WALL COMPATIBLE WITH BUILDING MATERIALS -29- f. Street Level Mechanical Equipment: All ground- mounted service equipment (e.g., air conditioners, transformers, trash collection equipment) related to each building will be consolidated in an enclosed service area. Landscaping will be used to soften the visual appearance of the walls enclosing the service area. Service areas must be paved, curbed, and intemally drained. Roof Mounted Mechanical Equipment: All roof mounted mechanical elements must be screened from view from the public right -of -way. Screening must be compatible with the building design. If roof decks with mechanical units are visible from any level of adjacent buildings, the mechanical units must be screened and painted to match the finished roof material. g. 7. Exterior Lighting. a. Minimal Spillover: All lighting must be installed to minimize light spillover onto adjacent properties. b. Parking Lot Fixtures: All light fixtures will be of a horizontal design with sharp cutoff edges. The fixture will be a rectangular box unit or a round puck -like unit (similar to Kim Lighting's Curvilinear Cutoff series) with a minimum diameter of 17" (width) and maximum diameter of 29" as detailed on Exhibit "K". The fixture will be made of spun aluminum or similar quality material with sidewalls free of welds or fasteners and will have an illumination source of mercury vapor or metal halide. All fixtures and light standards will have a black or dark bronze powder coated finish. Fixture glass must be white or clear. Light standards will be metal poles 40 feet high. (refer to figure 2) c. Open Space, Walkway and Passenger Drop Off Areas: All light fixtures will be of a horizontal design with sharp cutoff edges. The fixture will be a rectangular box unit or a round puck -like unit (similar to Kim Lighting's Curvilinear Cutoff series) with a minimum diameter of 17" (width) and maximum diameter of 29" as detailed on Exhibit "K". The fixture will be made of spun aluminum or similar quality material with sidewalls free of welds or fasteners and will have an illumination source of mercury vapor or metal halide. All fixtures and light standards will have a black or dark bronze powder coated finish. Fixture glass must be white or clear. Light standards will be metal poles between 10 and 15 feet high. (refer to figure 2) La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 4 -30- WALKWAY LIGHTING 41M d PARKING & ROADWAY LIGHTING figure 2 S. Landscaping. a. Existing Trees: Existing large mature trees will be retained in accordance with the Code. b. Tree Protection: All existing trees of six (6) inch caliper or greater must be indicated on the proposed site plans. The proposed site plans will indicate trees to remain and those to be removed. All trees within an approved building site which are required to be preserved in accordance with the Code must be flagged and encircled with protective fencing. The fencing must extend beyond the full spread on the tree's branches to reasonably ensure successful protection. Existing trees in parking areas will be saved in groups and as specimens whenever practicable. c. Open Space: All areas not containing buildings, structures, parking lots, sidewalks, fountains, site furniture or other improvements, including, but not limited to, front, side and rear building set back areas, and all areas between the curb line and the property line, must be planted, landscaped, and maintained in good condition. The landscape planting design must provide for easy maintenance. Utility easements will be landscaped consistent with other landscape areas where allowed by the respective utility company. d. Rights of Way: Areas within the road right -of -way may be landscaped only in accordance with a license agreement with the City. e. Grass: All landscaped areas not in groundcover or shrub beds will be planted in grasses, preferable sod. Overseeding in fall with cool season native grasses is allowed. The use of edging material to separate all grass areas from shrub and groundcover areas is required. The edging material will be concrete, steel, brick or La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 5 -31- stone. No plastic edging is allowed. Use of narrow paving "mowstrips" are allowed around building foundations for easy maintenance. f. Irrigation: An underground, automatic irrigation system must be installed in all landscaped areas. Sprinkler heads must be located to effectively water the landscaped areas with minimal spray onto roadways, parking areas and walkways. Screening of Parking: Parking areas must be screened visually from all roadways in accordance with the Code. Screening may be accomplished with landscaping or buildings. Berms may not exceed a 3:1 pitch. Shrubbery must be maintained to a minimum height of 3 feet. (refer to figure 3) g. PARKING SHALL BE SCREENED FROM ROADWAYS STREET LANDSCAPE EASEMENT PARKING AREA h. Parking Areas: In all vehicular use areas and parking areas, a minimum of 90 square feet for each 12 parking spaces must be devoted to landscaped strips, islands, peninsulas, medians, or other landscaped areas (the "Minimum Parking Area Landscaping Requirement "). As partial fulfillment of the Minimum Parking Area Landscaping Requirement, any parking area containing five or more parking rows of double vehicle depth will include a landscaped strip no less than ten feet (10 ") wide at least every fourth parking row of double vehicle depth. The landscaped strip will be installed with trees planted no less than every 60 linear feet. La Frontera East - PUD No. 38 Permitted Uses and Limitations Page 6 figure 3 9. Utility Lines. All utility service lines must be underground to connection points provided by the utility service provider. All transformers must be screened. -32- La Frontera East - PUD No. 38 Project Identification Sign Locations Page 1 of 1 PROJECT IDENTIFICATION SIGN LOCATIONS EXHIBIT E -33- EXHIBIT F COMBINATION SIGN AND MONUMENT SIGN LOCATIONS jON YL :•1 K r 111 SIGNS - -Ctl PYLON SIGN 2 MONUivINT 40 PYLON y* .� ■� �tiw s DOWD (55'-O x 8'-09 �� ► /i: :1:11;ikr. ..Z11774, rl La Floater Past - PUD No. 38 Combination Sign and Monument Sign Locations Page 1 of 1 -34- La Fronter East - PUD No 38 Utility Schematic and Drainage Plan Page 1 of 1 EXHIBIT G UTILITY SCHEMATIC AND DRAINAGE PLAN -35- (TEM art DESCRIPTION TSWREF CU MU 1 1 I POLE. SOUARE S1RNGHF. STEEL PAIRED DABS BRONZE. ANCHOR BASE 213.110 SlP52530'00 ROOM 2 1 1 LIRANWRE (A5 00021 273 -102 lR - 100 3 " 1 i FOUNDATION 20.170 2(325 760 JJJ 1 I CONOUCTOR.BN PO4E7 11111 R00 1 I POLE GROUND RNGJAEO IN 5 21050IO4 CIA 1 j FUSING 1300 1000 93' AO' 1 I 11010WAY AM COA161CI1. I)ROEq REBID 1906C60UN0 ' 1031E OR 001111E LIAMO/EE %WAGE nu 1.CURf IM MOM= METAL O711w1L !MOM VARR. ROOM NAME 18100, 1d1111•3 M. 09/1399011 'A' 1T5 100 TN SS S — 760 750 70 3p R00 400 b 113 — 1300 1000 93' AO' 213 - 530 10 -OS EXHIBIT ROADWAY LIGHT FIXTURES ' STREET UGHT LUMINAIRE RECTANGULAR - UNDERGROUND - SQUARE STEEL POLE - ANCHOR BASE La Frontera East - PUD No. 38 A P P R O V E D B Y HUE/ FCT R/c Roadway Light Fixtures Page 1 of 1 213-530 0_.5 -36- La Fronteca East - PUD No. 38 Permitted Outdoor Sales Ages Page 1 of 1 EXHIBIT I PERMITTED OUTDOOR SALES AREA -37- 0 La Frontera East - PUD No. 38 Sidewalk Locations Page 1 of 2 EXHIBIT J SIDEWALK LOCATIONS Standard Sidewalks 0 -38- 0 EXHIBIT 7 SIDEWALK LOCATIONS Wide Sidewalk La Frontera East - PUD No. 38 Sidewalk Locations Page 2 of 2 -39- PARKING LOT AND WALKWAY LIGHT FIXTURES SPECIFICATIONS AND DETAILS ARM MOUNT STANDARD ARM MOUNT MOUNTING OPTIONS Dealt Vertical Sllpftter Mound: Aeows standard liana and appal ann to be moaned a poles hevmg a 2 oPe size tenon (2b• OD ear mm wen My mounting g Coniguabn Can be used (th 2H. 2t. 3r « act. 4• die. Cell aluminum sigh Rush cap. secured . by (4) eh• alamkae awes set point alien scows Feigned to match Wore and arm. DmiamMr.2 Dom* rw.enwno`wrr. r,3Yernooevic Horizontal SUpIldar Mamb Cast aluminum darnµ hae *Aber moue MI *e sa screw all-lomdon Jock Cols to housing tom maids 01Bdmi001 compar - -1ml wing Muting hales to standard support era Haar damps to sly horizontal pole davl* -em1 with 2' pipe size mounag end (2% O.D.J. Pinioned to math &lure and arm. La Frontera East - PUD No. 38 Parking Lot and Walkway Light Fixtures Page 1 of 1 EXHIBIT K SPECIFICATIONS AND DETAILS POST TOP MOUNT MOUNTING OPTIONS La Fronter East - PUD No. 38 Traffic Impact Analysis Page 1 of 37 TRAFFIC IMPACT ANALYSIS LA FRONTERA TRAFFIC IMPACT ANALYSIS Prepared For EXHIBIT L 35 / 45 Investors, L.P. Original Submission: September 1998 Interim Submission: November 1998 December 1998 Final Submission: February 1999 WHM -41- LA FRONTERA TRAFFIC IMPACT ANALYSIS Prepared For 35 / 45 Investors, L.P. 801 W. 10th Street Austin, Texas 78701 Phone: 512- 322 -0112 Fax: 512- 322 -0124 Prepared by WHM Transportation Engineering Consultants, Inc. 2717 Rio Grande Street Austin, Texas 78705 Phone: 512- 473 -8343 Fax: 512 -473 -8237 SSE O TF�z i + f* F HEIDI RAE WESTERFIELD i Original Submission: September 1998 i Q m i , 2 'Ci Interim Submission: November 1998 I . December 1998 Ik 790 P Final Submission: February 1999 ,t�e:� �,E= 2 ! (ol q TABLE OF CONTENTS Page List of Figures i i List of Tables i i i Synopsis Introduction 5 Site and Access Characteristics 5 Existing Thoroughfare System 5 Future Roadway Improvements 5 Traffic Analysis 6 1998 Existing Conditions 7 2004 Forecasted Conditions with Site Generated Traffic 10 Directional Distribution 10 Analysis Assumptions I3 Intersection Analysis 14 Driveway Spacing on Adjacent Roadways 19 Roadway Cross - Sections 25 Summary and Recommendations 30 References 32 LIST OF FIGURES Figure Page 1 Area Location Map 3 2 La Frontera Parcels 4 3 Existing Traffic Volumes 8 4 Existing Lane Use and Level of Service 9 5 Site Traffic Distribution Before SH 45 Construction 15 6 Site Plus Forecasted Traffic Volumes Before SH 45 Construction 16 7 Site Plus Forecasted Lane Use and Level of Service Before SH 45 Construction 17 8 Site Traffic Distribution After SH 45 Construction 18 9 Driveway Locations Before SH 45 Construction 23 10 Driveway Locations After SH 45 Construction 24 11 Typical Street Section: Hester's Crossing, La Frontera Boulevard, Parker Drive 26 12 Typical Street Section: Sundance Parkway (Western End), Kouri Drive 27 13 Typical Street Section: Sundance Parkway (Eastern End) 28 14 Typical Street Section: Northline Boulevard 29 WHM Transportation Engineering Consultants, Inc. LIST OF TABLES Table Paee 1 Trip Generation Estimates - La Frontera Proposed Development 11 2 Adjusted Trip Generation Estimates - La Frontera Proposed Development 12 3 Forecast Directional Distribution of Site Oriented Traffic 13 WHM Transportation Engineering Consultants, Inc. iii LA FRONTERA TRAFFIC IMPACT ANALYSIS SYNOPSIS La Frontera is a 327 acre mixed -use development project located in southern Williamson County at the intersection of IH 35 and FM 1325 as shown in Figure 1. Proposed land uses include retail, office, hotel, cinema and restaurants. The site is bounded by IN 35 on the east, by FM 1325 on the south, by Quick Hill Road and undeveloped land on the west, and by a mixture of commercial and residential development on the north Figure 2 shows a more detailed view of the La Frontera property and defines the parcels used for land use assumptions. The traffic - related characteristics of the proposed development activities require evaluation to determine their effect on the adjacent roadway network. An analysis was conducted that evaluated the impact of traffic generated by the project with the findings and recommendations reported herein. The purpose of the Traffic Impact Analysis (PIA) is to examine the interaction of existing and planned land use activities, their intensity and traffic characteristics, and identify actions that would create a successful, effective and safe development program under both existing and future traffic conditions. A TIA for the project was conducted utilizing accepted traffic engineering methods and techniques. Existing traffic conditions were examined on area roadways and at selected intersections and compared with traffic conditions that could be expected at buildout of the project considering both site generated and external (background) traffic. Based on the analysis, recommended actions were identified and are summarized as follows: The following recommendations are provided for traffic conditions existing prior to the construction of SH 45: (1) Hester's Crossing should be extended from its current termination point west of IH 35 through the site to Quick Hill Road. (2) A divided arterial should be constructed from Hester's Crossing to the south to intersect FM 1325 at the Limestone Ranch driveway. This intersection should be signalized. (3) Site circulation roadways being constructed as part of the project should align with Parker Drive and Northridge Drive. Parker Drive is assumed to be signalized. Recommended intersection geometries are shown in Figure 7. (4) Adequate intersection spacing to allow appropriate left turn lanes and vehicle storage should be provided within the site, particularly along the proposed arterial extension from Hester's Crossing to FM 1325. (5) Dual left turn lanes should be provided along FM 1325 with the proposed signalized intersections discussed previously and as shown in Figure 7. This improvement'should be coordinated with TxDOT since FM 1325 is a state facility. (6) The benefits derived through trip generation reductions due to synergy among land uses will be increased for the proposed land uses due to the comprehensive roadway network proposed through the site and the ability for the network to distribute traffic to all directions without using adjacent roadways. (7) Capital Metro service is not currently available within the area of the site. For this reason, it will be desirable to encourage travel demand management as much as possible among the site land uses; i.e., car/van pools and staggered work hours. The following recommendations are provided for traffic operations in the vicinity of the site with the construction of SH 45: (1) An underpass should be constructed for FM 1325 to pass beneath the mainlanes of SH 45 to extend as an arterial north through the La Frontera site to Hester's Crossing. With the construction of SH 45, it will be necessary to realign FM 1325 to create a 90 degree intersection with the freeway frontage roads. The intersections of FM 1325 with the SH 45 eastbound and westbound frontage roads should be signalized. (2) Site internal roadway intersections with Parker Drive and Northline Drive will become right -in, right -out driveways as a result of the SH 45 freeway and frontage road construction. WHM Transportation Engineering Consultants, Inc. 2 ...� r •x[ r ''" "r Roan i s 4 A , Bock .ArW� 'd,� e ;' - . yt-- -c,:,.a.,,,1 `' -- i ieii ,: s F *' + -.' Cf: �i , x r , I - • r \'''' 'si.. / e 1 .�€t4 _ / „1.16.7e . S' 1 . ,k �l. art et u _ inn 4 'Na G ° 9 — V .: R :'l_\ a+ - xmo n.. i of.:'CAL:.: :..\ '1 . . l• SITE 1 -. ° -}y 7 1 ''-' a . -�� ° !LIMN R ° • NO ° RI - CENT •' • `tom, [ BR air c; i I 78728 BRATTON PARK a • ; / �� w 11 .�n. _ 4 ' wYv�!...1 - Z �+r Three ° � " +-0Points a «[`. it NORTH WI-IM FIGURE 1 AREA SITE LOCATION Tran: En°in.w.in° r'<,.,< „tia<a< I,.- . G..oi° To.n. P INTRODUCTION La Frontera is a 327 acre mixed -use development project located in southern Williamson County at the intersection of I1-I 35 and FM 1325 as shown in Figure 1. Proposed land uses include retail, office, hotel, cinema and restaurants. The site is bounded on the east by IH 35, on the south by FM 1325, on the west by Quick Hill Road and undeveloped land, and a mixture of commercial and on the north by residential development. It is projected that the development of this site will be completed by 2004. Site and Access Characteristics Figure 2 shows the location of development parcels within the project. Access for this project is proposed through site circulation roadways which connect to IH 35, FM 1325, Quick Hill Road, and Hester's Crossing. The internal roadway network will be constructed with the project development. Since the project is located along IH 35 and FM 1325 the programmed development activities and traffic related characteristics require evaluation. Examining the interaction of existing and programmed land use activities, their intensity and traffic characteristics is necessary to render an appreciation of appropriate actions required to create a successful, efficient, and safe program. This report on the analysis of the traffic conditions, present and future, addresses these objectives. EXISTING THOROUGHFARE SYSTEM As indicated on the area wide and site location maps (Figures 1 and 2), the project is located at the intersection of IH 35 and FM 1325. Other nearby roadways of importance include Hester's Crossing, Quick Hill Road, and Greenlawn Boulevard. The interrelationship of these roadways and others in the area is shown on the previous Figure 1. FUTURE ROADWAY IMPROVEMENTS Several pertinent roadway improvements have been recommended and approved by the Round Rock City Council, Williamson County Commissioner's Court, and the Texas Department of Transportation (Ref. 1, 2). WHM Transportation Engineering Consultants, Inc. 5 TRAFFIC ANALYSIS Hester's Crossing: Hester's Crossing will be extended from its current termination point west of IH 35 through the site to Quick Hill Road as a part of project development. FM 1325 (SH 45): The Texas Turnpike Authority has underway a consultant contract to prepare route location, environmental studies, tollway studies, and preliminary design for SH 45 from Lake line Boulevard to south of the San Gabriel River. The current alignment falls within the southern portion of the project site. A portion of FM 1325 is planned for reconstruction and realignment as a part of the construction of SH 45. Current plans include realignment of FM 1325 to intersect the eastbound SH 45 frontage road midway between IH 35 and Loop 1. Development of La Frontera anticipates the realignment and extension of FM 1325 to the north to Hester's Crossing. This roadway would be extended beneath the SH 45 main lanes and create signalized intersections with the frontage roads. A request has been submitted to the Round Rock City Council for inclusion of this arterial extension on the City's Thoroughfare Plan. SH 45 will most likely not be constructed prior to buildout of the La Frontera site. Greenlawn Boulevard: This street currently intersects CR 170 (Louis Henna Boulevard) east of IH 35. Current plans include extension of this roadway to the south to intersect the northbound frontage road of IH 35. Ultimate plans indude overpasses at SH 45 and IH 35. In order to assess the traffic implications of the proposed development, two time periods and travel conditions were evaluated: (1) 1998 - Existing Conditions (2) 2004 - Forecasted with Site Generated Traffic Conditions Intersections in the vicinity of the site are considered the locations of principal concern because they are the locations of highest traffic conflict and delay. The standard used to evaluate traffic conditions at intersections is Level of Service (LOS), which is a qualitative measure of the effect of a number of factors such as speed, volume of traffic, geometric features, traffic interruptions, freedom to maneuver, safety, driving comfort, convenience, and operating cost. WHM Transportation Engineering Consultants, Inc. 6 Analysis was performed using the microcomputer program "Highway Capacity Software" by the Federal Highway Administration (Ref. 3), which is based on the procedures contained in the Highway Capacity Manual (Ref. 4), as well as PASSER III (Ref. 5). 1998 Existing Conditions The analysis of existing traffic required the acquisition of secondary data from the City of Round Rock, as well as the collection of primary data on the major roadways and intersections. A field survey was designed through discussions with City staff and implemented to obtain the necessary data and to verify the trends established by data available from previous years. Signalized Intersections The following intersections within the study area are signalized: • IH 35 and Hester's Crossing • FM 1325 and CR 172 (Quick Hill Road) • FM 1325 and Northridge Road Existing peak hour traffic volumes at the above intersections and other locations adjacent to the site are presented in Figure 3. Current lane use and level of service are summarized in Figure 4. WHM Transportation Engineering Consultants, Inc. 7 551 170 I o x 442 NORTH NOT TO SCALE LA FRONTERA SITE Ak r 4'/\ ,a110- r 1682/1526 —► 13/51 .- 1449/1573 f— 4/68 Si 1 30 19 0 14 t iVA OP HESTER'S CROSSING / L 1651/1384 130/ 72 ---s 30 430 325 33 Ifff 569 105/263 —v 1 120/155 11 1 1l .-- 1519/1518 160/67 ■ 7 36 83 161 133/440 „e--- 867/720 l x 1 " / 1353 1023 6 20 M = PEAK HOUR VOLUME 160/406 _Je 270/426 —• -0 yy y 104 382 725 FM 1325 CR 170 FIGURE 3 EXISTING TRAFFIC VOLUMES 1 • B B NORTH NOT TO SCALE LA FRONTERA SITE HESTER'S CROSSING 1 4 I N1/414 1/4 -r I 4-- r— F +— •— B # .0 R F — ." A 0-< 1,7"-( .-- ( a ,A� do to AkFR b2 D D M FM 1325 CR 170 FIGURE 4 EXISTING INTERSECTION LEVEL OF SERVICE 2004 Forecasted Conditions With Site Generated Traffic The year 2004 was established as the year in which the project would become fully occupied This time frame was utilized to assess the major roadway effects and to facilitate the evaluation of alternative improvements. Forecasted traffic was projected using available information. This process was facilitated by using trends established by prior data for the major roadways in the immediate vicinity of the project site. Site Generated Traffic Determining the generated traffic or the traffic which is considered to be contributed by development of the proposed project was a major analysis process element. Total trips per day as well as the peak hour traffic associated with the project were estimated ocing the microcomputer program 'Trip Generation" by Microtrans Corporation (Ref. 6), which is based on recommendations and data contained in the Institute of Transportation Engineers report Trip Generation (Ref. 7). Table 1 provides a detailed summary of the traffic production which is directly related to the assumed land use activity. As a point of reference, the total PM peak hour trips were estimated at 9,588. Table 2 summarizes trip generation estimates which have been adjusted in accordance with analysis assumptions discussed in the following section_ The adjusted total PM peak hour trip generation is 7,122. Directional Distribution Once site generated trips were known, the next step involved distribution of those trips to appropriate geographic directions and logical connecting roadways. The major thoroughfares which have a direct bearing on the accessibility of the project have been previously identified. Traffic counts conducted during the study provided the basis for the directional distribution of traffic approaching and departing the project site as summarized in Table 3. Given the total site generated traffic and the directional distribution by approach, the next step in the process was to assign the traffic destined to and from the project to the most likely travel paths. This was done by investigating a number of alternative travel patterns as well as ingress /egress points along the project boundaries. Primary consideration was given to the traffic flow and safety of the major roadways. WHM Transportation Engineering Consultants, Inc. 10 TABLE 1. TRIP GENERATION ESTIMATES - LA FRONTERA PROPOSED DEVELOPMENT Lot Number Land Use Size SF Daily Traffic Volume AM Peak Hour Enter Exit PM Peak Hour Enter Exit Buildout y ear 1 Office 35,937 605 73 10 20 99 1999 2 Office 55,539 845 103 14 24 117 1999 3 Office 118,701 1,514 188 26 36 176 2000 4 Office 52,272 806 98 13 23 114 2000 5 Office 74,052 1,054 129 18 28 135 2000 6 Office 126,324 1,588 198 27 38 183 2002 7 Office 287,496 3,165 395 54 73 356 2001 8 Office 392,040 4,316 538 73 99 485 2003 9 Office 63,162 933 114 16 26 125 2002 10 Office 141,570 1,733 216 30 40 198 2003 11 Office 202,554 2,230 278 38 51 250 2004 12A Office 99,317 1,320 163 22 32 158 2001 12B Office 99,317 1,320 163 22 32 158 2002 13 Of 167,706 1,974 248 34 45 222 2000 14A Hotel 200 rms 1,646 68 44 65 57 2000 14B Office 200,376 2,206 275 38 51 248 2000 16 Hotel 120 rms 988 41 26 39 34 2004 17 Hotel 120 rms 988 41 26 39 34 1999 18 Hotel 90 rms 741 31 20 29 26 1999 19 Hotel 90 rms 741 31 20 29 26 2000 15 +28 Cinema 4500 seats - - - 334 296 2000 20 Restaurant (HTSit-clown) 10,454 1,363 50 47 68 45 2000 21 Restaurant (HT Sit -down) 8,886 1,158 43 40 58 39 2000 22 Restaurant (HT Sit-down) 9,409 1,226 45 42 61 41 2000 23 Restaurant (HT Sit-down) 5,750 749 28 26 37 25 2000 24 Restaurant (HT Sit -down) 5,750 749 28 26 37 25 2001 25 Restaurant (HT Sit -down) 11,500 1,499 55 51 75 50 2001 ' 26 Restaurant (HT Sit-down) 9,932 1,295 48 44 65 43 2001 27 Restaurant (HT Sit -down) 11,500 1,499 55 51 75 50 2001 29 Shopping Center 607,727 26,084 382 244 1,091 1,182 1999 Subtotal 2,797,271 66,335 4,125 1,142 2,720 4,997 620 rms 4,500 seats Wedge Shopping Center 1,306,800 l2,339 181 115 516 559 2001 Wedge Shopping Center 435,600 4,113 60 38 172 186 2002 Wedge Office 653,400 3,237 404 • 55 74 364 2003 Subtotal 2,395,800 19,689 645 208 762 1,109 TOTAL Trips 86,024 4,770 1,350 3,482 6,106 WHM Transportation Engineering Consultants, Inc. 11 TABLE 2. ADJUSTED TRIP GENERATION ESTIMATES LA FRONTERA PROPOSED DEVELOPMENT Lot Number Land Use Size SF Daily Traffic Volume AM Peak Hour Enter Exit PM Peak Hour Enter Exit Buildout Year 1 Office 35,937 514 621 9 17 84 1999 2 Office 55,539 718 88 12 20 99 1999 3 Office 118,701 1,287 160 22 31 150 2000 4 Office 52,272 685 83 11 20 97 2000 5 Office 74,052 896 110 15 24 115 2000 6 Office 126,324 1,350 168 23 32 156 2002 7 Office 287,496 2,690 336 46 62 303 2001 8 Office 392,040 3,669 457 62 84 412 2003 9 Office 63,162 793 97 14 22 106 2002 10 Office 141,570 1,473 184 26 34 168 2003 11 Office 202,554 1,896 236 32 43 213 2004 12A Office 99,317 1,122 139 19 27 134 2001 12B Office 99,317 1,122 139 19 27 134 2002 13 Office 167,706 1,678 211 29 38 189 2000 14A Hotel 200 rms 1,399 58 37 55 48 2000 14B Office 200,376 1,875 234 32 43 211 2000 16 Hotel 120 rms 840 35 22 33 29 2004 17 Hotel 120 rms 840 35 22 33 29 1999 18 Hotel 90 rms 630 26 17 25 22 1999 19 Hotel 90 rms 630 26 17 25 22 2000 15 +28 Cinema 4500 seats - - - 284 252 2000 20 Restaurant (HT Sit-down) 10,454 695 26 24 35 23 2000 21 Restaurant (HT Sit -down) 8,886 591 22 20 30 20 2000 22 Restaurant (HT Sit -down) 9,409 625 23 21 31 21 2000 23 Restaurant (HT Sit -down) 5,750 382 14 13 19 13 2000 24 Restaurant (HT Sit -down) 5,750 382 14 13 19 13 2001 25 Restaurant (HT Sit -down) 11,500 764 28 26 38 26 2001 26 Restaurant (HT Sitdown) 9,932 660 24 22 33 22 2001 27 Restaurant (HT Sit-down) 11,500 764 28 26 38 26 2001 29 Shopping Center 607,727 16,407 240 153 686 743 1999 Subtotal 2,797,271 47,377 3,302 806 1,909 3,878 620 rms 4,500 seats Wedge Shopping Center 1,306,800 8,495 125 79 355 385 2001 Wedge Shopping Center 435,600 2,552 37 24 107 115 2002 Wedge Office 653,400 2,751 343 47 63 309 2003 Subtotal 2,395,800 13,799 505 150 525 810 TOTAL Trips 61,176 3,807 955 2,434 4,688 WHM Transportation Engineering Consultants, Inc. 12 Table 3. Forecast Directional Distribution of Site Oriented Traffic Direction % of Site Traffic Entering Exiting North on lH 35 25 25 South on IH 35 30 30 West /south on FM 1325 30 30 East on Louis Henna Boulevard 5 5 Easton Mays Street 5 5 North on Quick BE Road —5 Total 100 100 Analysis Assumptions The traffic impact analysis process involves the use of primary data and engineering judgment on transferable parameters. Specifically, engineering judgment is required for estimation of background traffic growth and transit trip reductions, both of which are further described below. Background Traffic Background traffic volumes were determined based on an annual growth rates along FM 1325 as well as data contained in a recent study conducted for the City of Round Rock (Ref. 8). Pass -By Capture Studies have shown that retail land uses will capture from 20 to 60 percent of their traffic as pass -by trips, depending upon their size (Ref. 7). It is well documented that many other land uses also experience significant pass -by trip capture, such as fast food restaurants. The amount of trip reduction which each tract may attribute to the pass -by phenomenon will depend directly on the type of land use which is developed. internal Capture Once the total buildout of proposed land uses occurs, there will be interaction among the uses within this development. Internal capture is accounted for in two ways. First, to account for internal capture among similar retail land uses in adjacent areas, the sizes may be combined during the trip generation process. Because the equations used in trip generation estimations are logarithmic, the number of trips generated by a site WHM Transportation Engineering Consultants, Inc. 7$ does not increase in direct proportion to an increase in the square footage of a development. By combining retail projects in dose proximity to each other, a lower number of trips will be estimated, thereby taking into account the internal capture factor. The second way to account for internal capture is to reduce the expected number of trips directly by some percentage which reflects expected multipurpose trip - making among different types of land uses which are in dose proximity. However, as with pass -by trip reductions, internal capture depends on the type and quantity of land uses. Intersection Analysis The total 2004 traffic demand will be the sum of traffic generated by this proposed development, traffic generated by other development projects, and changes in existing traffic. Figure 5 summarizes projected AM and PM peak hour site traffic volumes at study area intersections prior to construction of SH 45. Buildout year AM and PM peak hour traffic volumes, including both site and background traffic, at study area intersections are presented in Figure 6. Recommended lane use and level of service analysis results are summarized in Figure 7. Upon completion of the construction of SH 45, access to the site will differ from that which will exist upon initial development. Planned modifications to the roadway network were described previously. Figure 8 illustrates projected site traffic volumes within the study area which will result from the roadway system modifications. WHM Transportation Engineering Consultants, Inc. 14 190 122 r 1 1 88 8 V, p y 5 m o o • m m 1 c P 0 1 m 1 0 E) 1 1 L 0 1 F 5 g a. 7 g 48 %234 15/80 1 NO TH NOT TO SCALE LA FRONTERA SITE 509 63 255 107 HESTER'S CROSSING / 256/1290 — . 1 89/488 --N N\ 459 3Q¢ 381 560 • 99/37 �� 1 r 691/384 70/103 208/1056_, 48/234 —► 1 1 & 1fo 2 1 1 � ) L ■14„___278/164 1 86 17 1�11�1 .4.----335/309 ) (■ , �- 560/274 1 475 �110 265/210 _�I 121/176 y 80 7 7 ��� 131 1 1 p4 i / /// 162/425 ----4k. 98/510 474 '' I'1 p - 'AA ) I'lk 3891 � �. p Ae PM =PEAK HOUR VOLUME 156 739 _--- 190/ FM 1325 1 CR 170 FIGURE 5 SITE TRAFFIC BEFORE SH 45 CONSTRUCTION 608 190 188 122 i i0 x t Dv I 5 o''' 29 200 488 88 \ NORTH ""R:7:= 48/2315/80 4 NOT TO SCALE 1 \ 28"L./ 1.gg 172 f / 33 I 475 389 � 113l0 � 110 600 2 119 /yyo 7 I� HESTER'S CROSSING LA FRONTERA SITE 16 32 265/210 2645/2204 14/56 17 33 17 33 121/176 le c le 2448/2125 —► 243/20 �, - /1290 -/297 381 459 -N; JI 99/373 83 57 I � 199 277 1 09 ��� 278/164 I I � 256/285 1 .4- 2032/2606 r J l {— 2330/24431 �— 4/75 j /" — 302/112 ■ 8 95 159 313 �R AM = PEAK HOUR VOLUME =' = INFORMATION NOT AVAILABLE - -- -/1101 -/1572 -/1056 -/782 —► FM 1325 FIGURE 6 CR 170 SITE + FORECASTED TRAFFIC BEFORE SH45 CONSTRUCTION NORTH NOT TO SCALE HESTER'S CROSSING LA FRONTERA SITE FM 1325 • :r r k. %it AM PM =' = INFORMATION NOT AVAILABLE u c-) 1 11i( FIGURE 7 CR 170 SITE + FORECASTED INTERSECTION LEVEL OF SERVICE 25 . 161 26 41 50 251 181 8 J 57 1Q I 24 5. 212/73 272/136 —r 2 41/42 —\ I /1 l i 13 94 j( 7 175 7 1 . 5 119 48/9 40 60/285 232 f 117/106 I( I J NOTH NOT TO SCALE LA FRONTERA SITE 310/140 .J 85/169 fff TT I ')1 34 212 142 1 162 185 i 1 107 561 348/287 —r 212/73 61/63 —\ 27 63/326 _ - / \ 15 2 142 3�1:7-1.- 3 / 2 4 1 \ 81 /g9. 347 \ \.......7.......9.t'.7.1 0 �3 243 73 1063 '.148/71 302 293 255/195 �( 319/663 N '%- 154/125 i ,� 649/626 t 397 575 188 ,,315 �8�i G 150 2O � ) 1r u:x. r. trss 509 63 258 107 ___663/344 HESTER'S CROSSING I �� 32/63 161/787—�-. 255/1290 —r 90/488 1 J 2122 I 381 523 99/373 _161/179 .*----730/459 PM = PEAK HOUR VOLUME 208/1096_ 47/194 — 286 FIGURE 8 SITE TRAFFIC AFTER SH 45 CONSTRUCTION f— 190/121 SH45 NFR SH45 SFR DRIVEWAY SPACING ON ADTACENT ROADWAYS The La Frontera site will be developed along the IH 35 West Frontage Road and FM 1325. When SH 45 is constructed through the area, the site will be located along the SH 45 North Frontage Road; FM 1325 will be realigned to intersect with La Frontera Boulevard within the La Frontera site. In order to provide for safe and efficient traffic operations in and around the La Frontera site, a comprehensive internal roadway network will be constructed as part of site development. With the high level of activity on roadways surrounding the site, it is desirable to move traffic from adjacent roadways into the site as efficiently as possible. The following recommendations have been developed for driveway locations along 114 35, FM 1325, and proposed SH 45. In general, it is recommended that a minimum 300 foot driveway spacing be maintained for the La Frontera site. As is always the case, driveways should be spaced as far apart as possible. Reflected in the following paragraphs are compromises developed between the City of Round Rock staff and the developer of the property on the number of driveways to be permitted within each section of roadway. The proposed driveway spacing and locations have been proposed in order to address City of Round Rock requirements. Any changes to proposed roadway alignments, intersection locations, or driveway spacing requirements described in the following paragraphs must be approved by the City of Round Rock. FM 1325 The La Frontera site will access FM 1325 via three future connections at Parker Drive, La Frontera Boulevard, and Northridge Road /Northline Drive. Given existing traffic conditions along FM 1325, additional access to the site via left turns is not recommended. The three proposed roadways which will provide left turn access from FM 1325 into the site will be sufficient to handle left turn demands. The roadways will be constructed to connect with additional internal site roadways, and will provide for efficient circulation within the site. As shown in Figure 9, as part of the internal roadway network, the developer proposes to construct a section of roadway between Parker Drive and La Frontera Boulevard at the future location of the SH 45 North Frontage Road to provide access to Kouri Avenue. When SH 45 is constructed, this internal connector roadway will no longer be necessary. WHM Transportation Engineering Consultants, Inc. 19 In addition to the fully directional access locations along FM 1325, WHM had proposed a limited number of right -in, right - out (RIRO) driveways to be constructed approximately midway between site access roadways with physical barriers (a raised median section) to prohibit left turn maneuvers into and out of the La Frontera site. At the request of the City of Round Rock, the property owner has agreed to construct only one limited access service driveway on the east side of the property frontage along FM 1325. Access to this driveway will be restricted to delivery vehicles. A crash gate will be installed on -site which will prevent the use of this driveway by the general public to access the remainder of the La Frontera development. Therefore, the only access along FM 1325 which will be available for use by the general public will be provided via the Parker Drive, La Frontera Boulevard and Northridge Road /Northline Drive intersections. TH 35 West Frontage Road Figure 9 shows a conceptual diagram of the site prior to construction of SH 45 (distances are dimensioned for reference purposes). A southbound exit ramp is located along the section of the IH 35 West Frontage Road in front of the La Frontera site. At a minimum, TxDOT requires that access be prohibited 50 feet upstream from the intersection of travelways of the ramp and the frontage road, and for a distance of 250 feet downstream from the intersection of travelways. The access - denied area of 300 feet which has been noted on Figure 9 is associated with the exit ramp. Sundance Parkway is proposed to be constructed on the La Frontera site approximately 380 feet south of the access - denied area associated with the exit ramp. This roadway will serve as a primary collector for La Frontera traffic. It is recommended that no site driveways be constructed between Sundance Parkway and the IH 35 exit ramp since weaving maneuvers will be occurring in this section. However, an additional driveway should be permitted north of the 300 foot access - denied area associated with the ramp (see Figure 9). In the future, the existing IH 35 southbound exit ramp is proposed to be removed in conjunction with construction of the IH 35 /SH 45 directional interchange. The City of Round Rock has indicated the desire to provide no additional driveways when the exit ramp is removed. The La Frontera property developers have agreed to the restriction requested by the City of Round Rock and will maintain the two proposed access points after the IH 35 ramp is removed_ The number of access points will not be increased at WHM Transportation Engineering Consultants, Inc. 20 any time in the future; however, the City of Round Rock has indicated it will consider the possibility of shifting access point locations along IH 35 frontage after removal of the existing exit ramp. SH45 When FM 1325 is replaced with SH 45, the La Frontera site will front the SH 45 North Frontage Road as shown in Figure 10. Access roadways from the SH 45 North Frontage Road into the La Frontera site will include Parker Drive, Kouri Avenue, La Frontera Boulevard, and Northline Drive. With the exception of La Frontera Boulevard, each of these access roadways will function as a RIRO roadway. La Frontera Boulevard is proposed to connect to FM 1325 south of SH 45. Based on discussions with the Texas Turnpike Authority and Turner Collie and Braden, Inc, the SH 45 westbound exit ramp which will serve the La Frontera site will be located east of Parker Drive. The limited access service driveway east of Parker Drive which will access FM 1325 prior to construction of SH 45 will most likely require removal due to access control restrictions associated with the SH 45 exit ramp_ All weaving will be accomplished prior to vehicles reaching Parker Drive. WHM has recommended that the section of La Frontera frontage along the SH 45 North Frontage Road should be restricted with a minimum driveway spacing requirement of 300 feet. However, in order to address comments from the City of Round Rock, proposed driveway locations have been restricted. Figure 10 shows proposed driveway locations. As shown on Figure 10, one driveway should be permitted between Parker Drive and Kouri Avenue, no driveways between Kouri Avenue and La Frontera Boulevard, two driveways between La Frontera Boulevard and Northline Drive, and one driveway between Northline Drive and the western property Line.. At no time should driveways be spaced less than 300 feet from each other or access roadways into the site. The single driveway proposed between Parker Drive and Kouri Avenue should be located midway between the two roadways (providing an approximate spacing of 360 feet between access points). This driveway will serve as a RIRO driveway for seven restaurant tracts. WHM Transportation Engineering Consultants, Inc. 21 The two driveways proposed between La Frontera Boulevard and Northline Drive will serve five tracts (two limited - service hotel tracts and three office tracts). The limited - service hotel tracts are shallow tracts which front the SH 45 frontage road and are located immediately west of La Frontera Boulevard. The provision of a single RIRO driveway to these two tracts will provide better operating conditions than the required configuration if the driveway were not constructed. If not permitted, a fully - directional access point to these sites would be required on La Frontera Boulevard. Since these sites are shallow in depth, it would be necessary to locate a median opening on the proposed arterial (La Frontera Boulevard) 150 to 200 feet north of the SH 45 frontage road. With a proposed underpass at the La Frontera Boulevard and SH 45 intersection, more than 200 feet will be required for queue storage of southbound traffic on La Frontera Boulevard. By providing a RIRO driveway on SH 45, a median opening on La Frontera Boulevard can be eliminated, thus providing more efficient operating conditions for all traffic traveling through the La Frontera Boulevard /SH 45 intersection The additional driveway proposed in the section between La Frontera Boulevard and Northline Drive will serve the remaining office tracts. WI-IM Transportation Engineering Consultants, Inc. 22 S <;CLiiC NORTH NOT TO SCALE t.Y0 vo LA FRONTERA SITE /S" HESTER'S CROSSING 1450' Limited Access Service Driveway 300'I 3801 O 1700' Access Denied FIGURE 9 tn FM 1325 DRIVEWAY LOCATIONS BEFORE SH 45 CONSTRUCTION NORTH NOT TO SCALE 800' 1400' LA FRONTERA SITE 'o 1 Driveway O 2 Driveways f No Driveways IP- 1 650' HESTER'S CROSSING SUNDANCE PKWY. d I 1 Driveway rb� • 720' 1700' Access Denied FIGURE 10 co ETI 51445 NFR SH45 SFR DRIVEWAY LOCATIONS AFTER SH 45 CONSTRUCTION ROADWAY CROSS - SECTIONS A well- developed internal circulation network will provide efficient access into and out of the site The proposed roadway network which will provide for internal circulation among land uses was shown in Figure 10. Patterns of egress and ingress were examined to determine the projected demand on each internal roadway. From there, appropriate cross - section recommendations were developed based on future vehicular traffic demands, pedestrian patterns, and land use requirements. Roadway cross- section recommendations are provided in the following figures (Figures 11 through 14). WHM Transportation Engineering Consultants, Inc. 25 14.0' 2.0' 10.0' 2.0' } SIDEWALK 1 ZONE 1 SIDEWALK 0 3I 5.0' 2.0' 17 24.0' 00' 4.0w. 201.0' 0 , i t 18.0' ! 16.0' fe 24.0' 2.0+ 10.0' `2.0', SIDEWALK 11 ZONE 1 SIDEWALK) FIGURE 11 N.T.S. TYPICAL STREET SECTION FIESTER'S CROSSING LA FRONTERA BOULEVARD PARKER DRIVE 1 14.0 2.0} 10.0 12.0' SIDEWALK 7 I ZONE 2.0 24.0' B0' R.0.0. 00 I 0 6.0' 6.0' 24.0' 2. 1 14.0 1 2.D' 10.0' `2.0� SIOEWALN 11 I ZONE FIGURE 12 TYPICAL STREET SECTION SUNDANCE PARKWAY (WESTERN END) KOURI DRIVE N.T.S. 0 a o' m f0 n 0 C 0 0 0 0 m 0 15.0' 2.0' - 10.0' ` 3.0' SIDEWALK 1 ZONE 5.0' S10EWALK O 5 . 1 5.0' 0' 3 70' 6.0.0. 36 ,,0• 3.0' 10.0' 2.0 { 510EWALK 1 1 ZONE SIDEWALK 7 CoSER6E TRENCH FIGURE 13 TYPICAL STREET SECTION SUNDANCE PARKWAY (EASTERN END) N.T.S. 5 76 0 0 rn 0 WIZ 3 I C s ; � d e 14.5' 2.0' 37.0• Z.0' 11•5' 10.0' 1 2.01 0.0' 10.0' } 1.5 510EWALK 1 00NE 5 { .D' 1 1 I 1 IOEWALN 0 11 5.0' 70' R.O.W. O o 15 A I e u 1 6.0' t I 0.0' 18 �I 1 I .= 2.5' 51DEWALN 51DEWALK ZONE FIGURE 14 TYPICAL STREET SECTION NORTHLINE BOULEVARD N.T.S. SUMMARY AND RECOMMENDATIONS The preceding analyses have illustrated the effects of site generated and forecasted traffic demand upon the street and roadway network adjacent to and in the vicinit of the project site. Generated traffic volumes were developed in a conservative scenario and assuming complete site development by 2004. Based on the analysis of existing and projected conditions and in order to provide the safest and most effective movement into and out of the site the following recommendations were developed. The following recommendations are provided for traffic conditions existing prior to the construction of SH 45: (1) Hester's Crossing should be extended from its current termination point west of IH 35 through the site to Quick Hill Road. (2) A divided arterial should be constructed from Hester's Crossing to the south to intersect FM 1325 at the Limestone Ranch driveway. This intersection should be signalized. (3) Site circulation roadways being constructed as part of the project should align with Parker Drive and Northridge Drive. Parker Drive is assumed to be signalized. Recommended intersection geometries are shown in Figure 7. (4) Adequate intersection spacing to allow appropriate left turn lanes and vehicle storage should be provided within the site, particularly along the proposed arterial extension from Hester's Crossing to FM 1325. (5) Dual left turn lanes should be provided along FM 1325 with the proposed signalized intersections discussed previously and as shown in Figure 7. This improvement should be coordinated with TxDOT since FM 1325 is a state facility. (6) The benefits derived through trip generation reductions due to synergy among c ia land uses will be increased for the proposed land uses due to the comprehensive roadway network proposed through the site and the ability for the network to distribute traffic to all directions without using adjacent roadways. WHM Transportation Engineering Consultants, Inc. 30 ( Capital Metro service is not currently available within the area of the site. For this reason, it will be desirable to encourage travel demand management as much as possible among the site land uses; i.e., car /van pools and staggered work hours. The following recommendations are provided for traffic operations in the vicinity of the site with the construction of SH 45_ (1) An underpass should be constructed for FM 1325 to pass beneath the mainlanes of SH 45 to extend as an arterial north through the La Frontera site to Hester's Crossing. With the construction of SH 45, it will be necessary to realign FM 1325 to create a 90 degree intersection with the freeway frontage roads. The intersections of FM 1325 with the SH 45 eastbound and westbound frontage roads should be signalized. (2) Site internal roadway intersections with Parker Drive and North. line Drive will become right -in, right -out driveways as a result of the SH 45 freeway and frontage road construction WHM Transportation Engineering Consultants, Inc 31 REFERENCES 1. Austin Metropolitan Area Transportation Plan Austin Transportation Study, December 12, 1994. 2. City of Round Rock Thoroughfare Plan, Update study underway by Rust Lichliter /Jameson 3. "Highway Capacity Software; United States Department of Transportation, Federal Highway Administration, January 1995. 4. Highway Capacity Manual (SR 209), Transportation Research Board, Washington, D.C., 1994. 5. PASSER III - 90 Texas Transportation Institute, Texas A &M University, College Station, Texas, March 1991. 6. Buttke, Carl H., "Trip Generation,' Microtrans Corporation, Portland, Oregon, 1997. 7. Trip Generation, 6th Edition, Institute of Transportation Engineers, Washington, D.C., 1997. 8. Traffic Study of the Southeast Commercial Access Plan, City of Round Rock, Rust Lichliter /Jameson, June 1998. WHM Transportation Engineering Consultants, Inc. 32 Date: February 19, 1999 Subject: City Council Meeting - February 25,1999 Item: 12.B.3. Consider an ordinance concerning adopting original zoning on 58.142 acres of land and rezoning 54.65 acres out of the JM Harrell Survey, A -284 from C -1 (General Commercial) to District Planned Unit Development 38 (PUD 38). (La Frontera East) (First Reading) On February 17,1999 the Planning and Zoning Commission recommended PUD 38 zoning on this tract of land. Applicant: Agent: W.S. Smalling. Staff Resource Person: Joe Vining, Planning Director La Frontera East Rezonin, and OH, inal Zonin, PUD 38