Loading...
CM-2026-236 - 9/18/2026 A PROFESSIONAL CONSULTING SERVICES AGREEMENT BETWEEN THE CITY OF ROUND ROCK AND PLUMMER ASSOCIATES,INC. RELATED TO THE COMPLETION OF CRITICAL ITEMS FOR THE BRUSHY CREEK REGIONAL WASTEWATER SYSTEM EAST WASTEWATER TREATMENT PLANT 30MGD EXPANSION PROJECT THE STATE OF TEXAS § THE CITY OF ROUND ROCK § KNOW ALL BY THESE PRESENTS COUNTY OF WILLIAMSON § COUNTY OF TRAVIS § THIS AGREEMENT(the "Agreement") for professional consulting services, specifically services related to the completion of critical items for the Brushy Creek Regional Wastewater System East Wastewater Treatment Plant 30MGD Expansion Project is made on this 18 day of lembe( , 2026, by and between the CITY OF ROUND ROCK, a Texas home-rule municipal corporation with offices located at 221 East Main Street, Round Rock, Texas 78664- 5299 (the"City"), and PLUMMER ASSOCIATES, INC., located at 8911 North Capital of Texas Highway, Suite 1350, Austin, Texas 78759 ("Consultant"). City and Consultant shall individually be referred to as a"party,"and collectively referred to as the "parties." RECITALS: WHEREAS, City has determined that it has a need for professional consulting services related to the completion of critically items remaining for the Brushy Creek Regional Wastewater System East Wastewater Treatment Plant 30MGD Expansion Project ("Consulting Services"); and WHEREAS,City desires to contract with Consultant for the Consulting Services; and WHEREAS, the parties desire to enter into this Agreement to set forth in writing their respective rights, duties and obligations hereunder; NOW, THEREFORE, in consideration of the mutual promises contained herein and other good and valuable consideration, the sufficiency and receipt of which are hereby acknowledged, it is mutually agreed between the parties as follows: 1.0 EFFECTIVE DATE,DURATION,AND TERM A. This Agreement shall be effective on the date set forth in the introductory paragraph above and shall remain in full force and effect unless and until it expires by operation of the term indicated herein, or is terminated as provided herein. CM -2021,-2 31 B. This Agreement shall expire upon successful completion of the services, estimated to be no later than July 31, 2027. C. City and the Consultant reserve the right to review the Agreement at any time and may elect to terminate the Agreement with or without cause. 2.0 CITY SERVICES City shall provide services set forth in the attached proposal attached as Exhibit "A," incorporated herein by reference for all purposes. 3.0 CONSULTING SERVICES Consultant shall satisfactorily provide all Consulting Services described herein and as set forth in Exhibit "B," attached hereto and incorporated herein for all purposes, pursuant to the Work Schedule set forth in Exhibit "C," attached hereto and incorporated herein by reference for all purposes. Consultant's undertaking shall be limited to performing Consulting Services for City and/or advising City concerning those matters on which Consultant has been specifically engaged. Consultant shall perform the Consulting Services in accordance with this Agreement in a professional and workmanlike manner. 4.0 LIMITATION TO CONSULTING SERVICES Consultant and City agree that the Consulting Services to be performed are enumerated in Exhibit"B," and may only be modified by a written Supplemental Agreement executed by both parties as described in Section 10.0. 5.0 CONTRACT AMOUNT A. In consideration for providing the Consulting Services, Consultant shall be paid in accordance with the rates and fees included in the attached Exhibit "D," attached hereto and incorporated herein by reference for all purposes. B. Consultant's total compensation for Consulting Services hereunder shall not exceed $100,000.00. This amount represents the absolute limit of City's liability to Consultant hereunder unless same shall be changed by Supplemental Agreement, and City shall pay, strictly within the not-to-exceed sum recited herein, Consultant's fees for work done on behalf of City. 6.0 INVOICE REQUIREMENTS AND TERMS OF PAYMENT A. Invoices: To receive payment, Consultant shall prepare and submit detailed invoices to the City, in accordance with the delineation contained herein, for Consulting Services rendered. Such invoices for Consulting Services shall detail the services performed, along with documentation for each service performed. Payment to Consultant shall be made on the basis of the invoices submitted by Consultant and approved by the City. Such invoices shall conform to 2 the amounts set forth in Exhibit"D." B. Backup Material. Should additional backup material be requested by the City relative to Consulting Services, Consultant shall promptly comply. In this regard, should the City determine it necessary, Consultant shall make all records and books relating to this Agreement available to the City for inspection and auditing purposes. C. Payment of Invoices: The City reserves the right to correct any error that may be discovered in any invoice that may have been paid to Consultant and to adjust same to meet the requirements of this Agreement. Following approval of an invoice,the City shall endeavor to pay Consultant promptly, but no later than the time period required under the Texas Prompt Payment Act described in Section 8 herein. D. Taxes. The City is exempt from Federal Excise and State Sales Tax. Therefore, such taxes shall not be included in Consultant's invoices. 7.0 INSURANCE Consultant shall meet all City of Round Rock Insurance Requirements set forth at: https://www.roundrocktexas.gov/wp-content/uploads/2024/12/CORR-Insurance-08-2024.pdf 8.0 PROMPT PAYMENT POLICY In accordance with Chapter 2251, V.T.C.A., Texas Government Code, any payment to be made by the City to Consultant will be made within thirty (30) days of the date the performance of the Consulting Services under this Agreement are completed, or the date the City receives a correct invoice for the Consulting Services, whichever is later. Consultant may charge interest on an overdue payment at the "rate in effect" on September 1 of the fiscal year in which the payment becomes overdue, in accordance with V.T.C.A., Texas Government Code, Section 2251.025(b). This Prompt Payment Policy does not apply to payments made by the City in the event: (1) There is a bona fide dispute between the City and Consultant, a contractor, subcontractor, or supplier about the service performed that cause the payment to be late; or (2) There is a bona fide dispute between Consultant and a subcontractor or between a subcontractor and its supplier about the service performed that causes the payment to be late; or (3) The terms of a federal contract, grant, regulation, or statute prevent the City from making a timely payment with federal funds; or (4) The invoice is not mailed to the City in strict accordance with any instruction on the purchase order relating to the payment. 3 9.0 NON-APPROPRIATION AND FISCAL FUNDING This Agreement is a commitment of the City's current revenues only. It is understood and agreed that the City shall have the right to terminate this Agreement at the end of any City fiscal year if the governing body of the City does not appropriate funds sufficient to purchase the Consulting Services as determined by the City's budget for the fiscal year in question. The City may affect such termination by giving Consultant a written notice of termination at the end of its then-current fiscal year. 10.0 SUPPLEMENTAL AGREEMENT The terms of this Agreement may be modified by written Supplemental Agreement hereto, duly authorized by City Council or by the City Manager, if the City determines that there has been a significant change in (1) the scope, complexity, or character of the Consulting Services to be performed; or (2) the duration of the work. Any such Supplemental Agreement must be executed by both parties within the period specified as the term of this Agreement. Consultant shall not perform any work or incur any additional costs prior to the execution, by both parties, of such Supplemental Agreement. Consultant shall make no claim for extra work done or materials furnished unless and until there is full execution of any Supplemental Agreement, and the City shall not be responsible for actions by Consultant nor for any costs incurred by Consultant relating to additional work not directly authorized by Supplemental Agreement. 11.0 TERMINATION AND DEFAULT A. Termination: It is agreed and understood by Consultant that the City may terminate this Agreement for the convenience of the City, upon written notice to Consultant (the "Date of Termination,") with the understanding that immediately upon receipt of said notice all work being performed under this Agreement shall cease. Consultant shall invoice the City for work satisfactorily completed and shall be compensated in accordance with the terms hereof for work accomplished prior to the Date of Termination. Consultant shall not be entitled to any lost or anticipated profits for work terminated under this Agreement. Unless otherwise specified in this Agreement, all data, information, and work product related to this Project shall become the property of the City upon termination of this Agreement and shall be promptly delivered to the City in a reasonably organized form without restriction on future use. Should the City subsequently contract with a new consultant for continuation of service on the Project, Consultant shall cooperate in providing information. Termination of this Agreement shall extinguish all rights, duties, and obligations of the terminating party and the terminated party to fulfill contractual obligations. Termination under this section shall not relieve the terminated party of any obligations or liabilities which occurred prior to termination. Nothing contained in this section shall require the City to pay for any work which it deems unsatisfactory,or which is not performed in compliance with the terms of this Agreement. 4 B. Default: Either party may terminate this Agreement, in whole or in part, for default if the Party provides the other Party with written notice of such default and the other fails to satisfactorily cure such default within ten (10) business days of receipt of such notice (or a greater time if agreed upon between the Parties). If default results in termination of this Agreement, then the City shall give consideration to the actual costs incurred by Consultant in performing the work to the date of default. The cost of the work that is useable to the City,the cost to the City of employing another firm to complete the useable work, and other factors will affect the value to the City of the work performed at the time of default. Neither party shall be entitled to any lost or anticipated profits for work terminated for default hereunder. The termination of this Agreement for default shall extinguish all rights, duties, and obligations of the terminating Party and the terminated Party to fulfill contractual obligations. Termination under this section shall not relieve the terminated party of any obligations or liabilities which occurred prior to termination. Nothing contained in this section shall require the City to pay for any work which it deems unsatisfactory, or which is not performed in compliance with the terms of this Agreement. 12.0 NON-SOLICITATION Except as may be otherwise agreed in writing, during the term of this Agreement and for twelve (12) months thereafter, neither the City nor Consultant shall offer employment to or shall employ any person employed then or within the preceding twelve (12) months by the other or any affiliate of the other if such person was involved, directly or indirectly, in the performance of this Agreement. This provision shall not prohibit the hiring of any person who was solicited solely through a newspaper advertisement or other general solicitation. 13.0 INDEPENDENT CONTRACTOR STATUS Consultant is an independent contractor and is not the City's employee. Consultant's employees or subcontractors are not the City's employees. This Agreement does not create a partnership, employer-employee, or joint venture relationship. No party has authority to enter into contracts as agent for the other party. Consultant and the City agree to the following rights consistent with an independent contractor relationship: (1) Consultant has the right to perform services for others during the term hereof. (2) Consultant has the sole right to control and direct the means, manner and method by which it performs its Consulting Services required by this Agreement. (3) Consultant has the right to hire assistants as subcontractors, or to use employees to provide the services required by this Agreement. 5 (4) Consultant or its employees or subcontractors shall perform Consulting Services required hereunder, and the City shall not hire, supervise, or pay assistants to help Consultant. (5) Neither Consultant nor its employees or subcontractors shall receive training from the City in skills necessary to perform Consulting Services required by this Agreement. (6) City shall not require Consultant or its employees or subcontractors to devote full time to performing the Consulting Services required by this Agreement. (7) Neither Consultant nor its employees or subcontractors are eligible to participate in any employee pension, health, vacation pay, sick pay, or other fringe benefit plan of the City. 14.0 CONFIDENTIALITY AND MATERIALS OWNERSHIP Any and all programs, data, or other materials furnished by the City for use by Consultant in connection with the Consulting Services to be performed under this Agreement, and any and all data and information gathered by Consultant, shall be held in confidence by Consultant as set forth hereunder. Each party agrees to take reasonable measures to preserve the confidentiality of any proprietary or confidential information relative to this Agreement, and to not make any use thereof other than for the performance of this Agreement, provided that no claim may be made for any failure to protect information that occurs more than three (3) years after the end of this Agreement. The parties recognize and understand that the City is subject to the Texas Public Information Act and its duties run in accordance therewith. All data relating specifically to the City's business and any other information which reasonably should be understood to be confidential to City is confidential information of City. Consultant's proprietary software, tools, methodologies, techniques, ideas, discoveries, inventions, know-how, and any other information which reasonably should be understood to be confidential to Consultant is confidential information of Consultant. The City's confidential information and Consultant's confidential information is collectively referred to as "Confidential Information." Each party shall use Confidential Information of the other party only in furtherance of the purposes of this Agreement and shall not disclose such Confidential Information to any third party without the other party's prior written consent, which consent shall not be unreasonably withheld. Each party agrees to take reasonable measures to protect the confidentiality of the other party's Confidential Information and to advise their employees of the confidential nature of the Confidential Information and of the prohibitions herein. Notwithstanding anything to the contrary contained herein, neither party shall be obligated to treat as confidential any information disclosed by the other party (the "Disclosing Party") which: (1) is rightfully known to the recipient prior to its disclosure by the Disclosing 6 Party; (2) is released by the Disclosing Party to any other person or entity (including governmental agencies) without restriction; (3) is independently developed by the recipient without any reliance on Confidential Information; or (4) is or later becomes publicly available without violation of this Agreement or may be lawfully obtained by a party from any non-party. Notwithstanding the foregoing, either party will be entitled to disclose Confidential Information of the other to a third party as may be required by law, statute, rule or regulation, including subpoena or other similar form of process, provided that (without breaching any legal or regulatory requirement) the party to whom the request is made provides the other with prompt written notice and allows the other party to seek a restraining order or other appropriate relief. Subject to Consultant's confidentiality obligations under this Agreement, nothing herein shall preclude or limit Consultant from providing similar services for other clients. Notwithstanding the foregoing, either party will be entitled to disclose Confidential Information of the other to a third party as may be required by law, statute, rule or regulation, including subpoena or other similar form of process, provided that (without breaching any legal or regulatory requirement)the party to whom the request is made provides the other with prompt written notice and allows the other party to seek a restraining order or other appropriate relief. Subject to Consultant's confidentiality obligations under this Agreement. Neither the City nor Consultant will be liable to the other for inadvertent or accidental disclosure of Confidential Information if the disclosure occurs notwithstanding the party's exercise of the same level of protection and care that such party customarily uses in safeguarding its own proprietary and confidential information. Notwithstanding anything to the contrary in this Agreement, the City will own as its sole property all written materials created, developed, gathered, or originally prepared expressly for the City and delivered to the City under the terms of this Agreement (the "Deliverables"); and Consultant shall own any general skills, know-how, expertise, ideas, concepts, methods, techniques, processes, software, or other similar information which may have been discovered, created, developed or derived by Consultant either prior to or as a result of its provision of Consulting Services under this Agreement (other than Deliverables). Consultant shall have the right to retain copies of the Deliverables and other items for its archives. Consultant's working papers and Consultant's Confidential Information (as described herein) shall belong exclusively to the Consultant. "Working papers" shall mean those documents prepared by Consultant during the course of performing the Project including, without limitation, schedules, analyses, transcriptions, memos, designed and developed data visualization dashboards and working notes that serve as the basis for or to substantiate the Project. In addition, Consultant shall retain sole and exclusive ownership of its know-how, concepts,techniques,methodologies, ideas,templates, dashboards, code and tools discovered, created or developed by Consultant during the performance of the Project that are of general application and that are not based on City's Confidential Information hereunder(collectively, "Consultant's Building Blocks"). To the extent any Deliverables incorporate Consultant's Building Blocks, Consultant gives City a non- exclusive, non-transferable, royalty-free right to use such Building Blocks solely in connection with the deliverables. Subject to the confidentiality restrictions mentioned above, Consultant may use the deliverables and the Building Blocks for any purpose. Except to the extent required 7 by law or court order, City will not otherwise use, or sublicense or grant any other party any rights to use, copy or otherwise exploit or create derivative works from Consultant's Building Blocks. City shall have a non-exclusive, non-transferable license to use Consultant's Confidential Information for City's own internal use and only for the purposes for which they are delivered to the extent that they form part of the Deliverables. 15.0 WARRANTIES Consultant represents that all Consulting Services performed hereunder shall be performed consistent with generally prevailing professional or industrial standards and shall be performed in a professional and workmanlike manner. Consultant shall re-perform any work not in compliance with this representation. 16.0 LIMITATION OF LIABILITY Should any of Consultant's services not conform to the requirements of the City or of this Agreement, then and in that event the City shall give written notification to Consultant; thereafter, (a) Consultant shall either promptly re-perform such Consulting Services to the City's reasonable satisfaction at no additional charge, or (b) if such deficient Consulting Services cannot be cured within the cure period set forth herein, then this Agreement may be terminated for default. In no event will Consultant be liable for any loss, damage, cost or expense attributable to negligence, willful misconduct or misrepresentations by the City, its directors, employees or agents. Neither party's liability, in contract, tort (including negligence) or any other legal or equitable theory, (a) shall exceed the professional fees paid or due to Consultant pursuant to this Agreement or (b) include any indirect, incidental, special, punitive or consequential damages, even if such party has been advised of the possibility of such damages. Such excluded damages include,without limitation, loss of data, loss of profits and loss of savings of revenue. 17.0 INDEMNIFICATION Consultant shall save and hold harmless City and its officers and employees from all claims and liabilities due to activities of his/her/itself and his/her/its agents or employees, performed under this Agreement, which are caused by or which result from the negligent error, omission, or negligent act of Consultant or of any person employed by Consultant or under Consultant's direction or control. Consultant shall also save and hold City harmless from any and all expenses, including but not limited to reasonable attorneys' fees which may be incurred by City in litigation or otherwise defending claims or liabilities which may be imposed on City as a result of such 8 negligent activities by Consultant, its agents, or employees. 18.0 ASSIGNMENT AND DELEGATION The parties each hereby bind themselves, their successors, assigns and legal representatives to each other with respect to the terms of this Agreement. Neither party may assign any rights or delegate any duties under this Agreement without the other party's prior written approval, which approval shall not be unreasonably withheld. 19.0 LOCAL,STATE,AND FEDERAL TAXES Consultant shall pay all income taxes, and FICA (Social Security and Medicare taxes) incurred while performing Consulting Services under this Agreement. The City will not do the following: (1) Withhold FICA from Consultant's payments or make FICA payments on its behalf; (2) Make state and/or federal unemployment compensation contributions on Consultant's behalf; or (3) Withhold state or federal income tax from any of Consultant's payments. If requested, the City shall provide Consultant with a certificate from the Texas State Comptroller indicating that the City is a non-profit corporation and not subject to State of Texas Sales and Use Tax. 20.0 COMPLIANCE WITH LAWS,CHARTER,AND ORDINANCES A. Consultant, its consultants, agents, employees and subcontractors shall use best efforts to comply with all applicable federal and state laws, the Charter and Ordinances of the City of Round Rock, as amended, and with all applicable rules and regulations promulgated by local, state and national boards, bureaus and agencies. Consultant shall further obtain all permits, licenses, trademarks, or copyrights required in the performance of the Consulting Services contracted for herein, and same shall belong solely to the City at the expiration of the term of this Agreement. B. In accordance with Chapter 2271, Texas Government Code, a governmental entity may not enter into a contract with a company for goods and services unless the contract contains written verification from the company that it: (1)does not boycott Israel; and(2)will not boycott Israel during the term of a contract. The signatory executing this Agreement on behalf of Consultant verifies Consultant does not boycott Israel and will not boycott Israel during the term of this Agreement. C. In accordance with Chapter 2274, Texas Government Code, a governmental entity may not enter into a contract with a company with at least ten (10) full-time employees for a 9 value of at least One Hundred Thousand and No/100 Dollars ($100,000.00) unless the contract has a provision verifying that it: (1) does not have a practice, policy, guidance, or directive that discriminates against a firearm entity or firearm trade association; and (2) will not discriminate during the term of the contract against a firearm entity or firearm trade association. The signatory executing this Agreement on behalf of Consultant verifies Consultant does not have a practice, policy, guidance, or directive that discriminates against a firearm entity or firearm trade association, and it will not discriminate during the term of this Agreement against a firearm entity or firearm trade association. D. In accordance with Chapter 2274, Texas Government Code, a governmental entity may not enter into a contract with a company with at least ten (10) full-time employees for a value of at least One Hundred Thousand and No/100 Dollars ($100,000.00) unless the contract has a provision verifying that it: (1) does not boycott energy companies; and (2) will not boycott energy companies during the term of this Agreement. The signatory executing this Agreement on behalf of Consultant verifies Consultant does not boycott energy companies, and it will not boycott energy companies during the term of this Agreement. 21.0 FINANCIAL INTEREST PROHIBITED Consultant covenants and represents that Consultant, its officers, employees, agents, consultants and subcontractors will have no financial interest, direct or indirect, in the purchase or sale of any product, materials or equipment that will be recommended or required hereunder. 22.0 DESIGNATION OF REPRESENTATIVE The City hereby designates the following representative authorized to act on its behalf with regard to this Agreement: Rebecca Vento Senior Engineer—Public Works Department (512) 341-3129 rvento(a,roundrocktexas.gov 23.0 NOTICES All notices and other communications in connection with this Agreement shall be in writing and shall be considered given as follows: (A) When delivered personally to recipient's address or email address as below; or (B) Three (3) days after being deposited in the United States mail, with postage prepaid to the recipient's address as stated below. 10 Notice to Consultant: Plummer Associates, Inc. 8911 North Capital of Highway Texas Suite 1350, Austin, Texas 78759 Notice to City: City Manager, City of Round Rock 221 East Main Street Round Rock, TX 78664 AND TO: Stephanie L. Sandre, City Attorney 309 East Main Street Round Rock, TX 78664 (C) Nothing contained in this section shall be construed to restrict the transmission of routine communications between representatives of the City and Consultant. 24.0 APPLICABLE LAW, ENFORCEMENT,AND VENUE This Agreement shall be enforceable in Round Rock, Texas, and if legal action is necessary by either party with respect to the enforcement of any or all of the terms or conditions herein, exclusive venue for same shall lie in Williamson County, Texas. This Agreement shall be governed by and construed in accordance with the laws and court decisions of Texas. 25.0 EXCLUSIVE AGREEMENT The terms and conditions of this Agreement, including exhibits, constitute the entire agreement between the parties and supersede all previous communications, representations, and agreements, either written or oral,with respect to the subject matter hereof. The parties expressly agree that, in the event of any conflict between the terms of this Agreement and any other writing,this Agreement shall prevail.No modifications of this Agreement will be binding on any of the parties unless acknowledged in writing by the duly authorized governing body or representative for each party. 26.0 DISPUTE RESOLUTION The City and Consultant hereby expressly agree that no claims or disputes between the parties arising out of or relating to this Agreement, or a breach thereof shall be decided by any arbitration proceeding, including without limitation, any proceeding under the Federal Arbitration Act(9 USC Section 1-14)or any applicable state arbitration statute. 11 27.0 SEVERABILITY The invalidity, illegality, or unenforceability of any provision of this Agreement or the occurrence of any event rendering any portion of provision of this Agreement void shall in no way affect the validity or enforceability of any other portion or provision of this Agreement. Any void provision shall be deemed severed from this Agreement, and the balance of this Agreement shall be construed and enforced as if this Agreement did not contain the particular portion of provision held to be void. The parties further agree to amend this Agreement to replace any stricken provision with a valid provision that comes as close as possible to the intent of the stricken provision. The provisions of this Article shall not prevent this entire Agreement from being void should a provision which is of the essence of this Agreement be determined void. 28.0 STANDARD OF CARE Consultant represents that it is specially trained, experienced and competent to perform all of the Consulting Services, responsibilities and duties specified herein and that such Consulting Services, responsibilities and duties shall be performed, whether by Consultant or designated subconsultants, in a manner acceptable to the City and according to generally accepted business practices. 29.0 GRATUITIES AND BRIBES City, may by written notice to Consultant, cancel this Agreement without incurring any liability to Consultant if it is determined by City that gratuities or bribes in the form of entertainment, gifts, or otherwise were offered or given by Consultant or its agents or representatives to any City Officer, employee or elected representative with respect to the performance of this Agreement. In addition, Consultant may be subject to penalties stated in Title 8 of the Texas Penal Code. 30.0 RIGHT TO ASSURANCE Whenever either party to this Agreement, in good faith, has reason to question the other party's intent to perform hereunder, then demand may be made to the other party for written assurance of the intent to perform. In the event that no written assurance is given within the reasonable time specified when demand is made,then and in that event the demanding party may treat such failure an anticipatory repudiation of this Agreement. 31.0 MISCELLANEOUS PROVISIONS (A) Time is of the Essence. Consultant agrees that time is of the essence and that any failure of Consultant to complete the Consulting Services for each Phase of this Agreement within the agreed Project schedule may constitute a material breach of the Agreement. 12 Consultant shall be fully responsible for its delays or for failures to use reasonable efforts in accordance with the terms of this Agreement. Where damage is caused to City due to Consultant's failure to perform in these circumstances, City may withhold, to the extent of such damage, Consultant's payments hereunder without a waiver of any of City's additional legal rights or remedies. City shall render decisions pertaining to Consultant's work promptly to avoid unreasonable delays in the orderly progress of Consultant's work. (B) Force Majeure. Notwithstanding any other provisions hereof to the contrary, no failure, delay or default in performance of any obligation hereunder shall constitute an event of default or breach of this Agreement, only to the extent that such failure to perform, delay or default arises out of causes beyond control and without the fault or negligence of the party otherwise chargeable with failure, delay or default; including but not limited to acts of God, acts of public enemy, civil war, insurrection, riots, fires, floods, explosion, theft, earthquakes, natural disasters or other casualties, strikes or other labor troubles, which in any way restrict the performance under this Agreement by the parties. (C) Section Numbers. The section numbers and headings contained herein are provided for convenience only and shall have no substantive effect on construction of this Agreement. (D) Waiver. No delay or omission by either party in exercising any right or power shall impair such right or power or be construed to be a waiver. A waiver by either party of any of the covenants to be performed by the other or any breach thereof shall not be construed to be a waiver of any succeeding breach or of any other covenant. No waiver of discharge shall be valid unless in writing and signed by an authorized representative of the party against whom such waiver or discharge is sought to be enforced. (E) Multiple Counterparts. This Agreement may be executed in multiple counterparts, which taken together shall be considered one original. The City agrees to provide Consultant with one fully executed original. [Signatures on the following page.] 13 IN WITNESS WHEREOF, the parties have executed this Agreement on the dates hereafter indicated. City of Ro nd Rock, T xas Plummer Associates, Inc. By: By: Perran Sean Hutton o-`".. m.,..:..mm Printed Name: 11LdC.S C++ Printed Name: Perran S. Hutton, PE Title: CII'-1-I1 Wove% Title: Team Leader Date Signed: q t$/2O2. , Date Signed: 9/15/2026 For City,Attest: By: (/-0)/M.4)&k.a Ann Franklin, City Clerk For City,Approved as to Form: BY: tephanie L. Sandre, City Attorney 14 Exhibit"A" City Services Brushy Creek East Regional WWTP • ti� 30 MGD Incomplete Items Work Packages ttiPLUMMER 098203201 Exhibit A City Services The City of Round Rock will furnish to the Engineer the following items/information: • Attend kickoff meeting and progress meetings. • Designate a person to act as City's representative with respect to the services to be performed or furnished by the Engineer. This representation will have authority to transmit instructions, receive information, interpret, and define City's policies and decisions with respect to engineering services. • Provide criteria and full information as to City's requirements for the project, including objectives and constraints and furnish copies of standards which City will require to be included in the project. • Assist Engineer by placing available information pertinent to the Project, including previous information and other data relative to the Project at the Engineer's disposal. Engineer will reasonably rely upon the accuracy, timeliness, and completeness of the information provided by the City. • City will give prompt notice to Engineer whenever City observe or become aware of development that affects the scope or timing of Engineer's services. • Provide digital design files or records available which would assist in the completion of the project development. • Governmental review fees, submittal fees, recordation fees, and other fees associated with the project shall be paid for directly by the City. • Timely review and comment, within 10 business days, on the deliverables. Exhibit"B" Consulting Services Brushy Creek East Regional WWTP 30 MGD Incomplete Items Work Packages 0982-032-01 EXHIBIT B Engineering Services Engineering/Professional Services to be provided for priority items from the 30 MGD expansion construction project.These incomplete items require working into"packages"for reassigning. Background The Brushy Creek East Regional Wastewater Treatment Plant(Plant)is owned by the Brushy Creek Regional Wastewater System (BCRWWS), who are the Cities of Round Rock (City), Cedar Park, Leander and Austin. The engineering team, led by Prime consultant Plummer Associates, and sub consultants Freese& Nichols and Lochner/Egis(Engineer)designed the most recent 10 MGD expansion, increasing the Plant's capacity to 30 MGD. The Engineer has also been providing construction administration services. On August 27th, 2026,the City of Round Rock terminated the general contractor(Thalle Construction Company)for multiple breaches of its contract with the City. As a result, the current 30 MGD construction project has not been completed per the design documents originally conformed by the Engineer in April 2020. The City is coordinating with the bond surety to complete the original scope of work and intends to hire a replacement contractor to complete the project as soon as possible.The Engineer will assist the City by providing review of the remaining "priority" scope items and creating work packages for an alternative contractor to price and ultimately execute. The City has retained the services of the Engineer to perform miscellaneous/engineering tasks on an "as needed" basis, for tasks deemed necessary by the City staff to assist in the planning, review, assessment, and preparation of the above referenced work packages for the incomplete construction scope. Basic Services: The purpose of this scope of services is to provide additional services for: 1. Review and assessment of the current incomplete work list [Attachment 1] 2. Field/site visits accompanying the City staff and potential general contractor(s)or their subs. 3. Coordination with current equipment suppliers. 4. Re-packaging of existing drawings and specifications to outline incomplete work for perspective contractors.This may also include field photographs and descriptive reports. 5. Assistance with producing bid forms. 6. Review of pricing and work plans submitted by prospective contractor. 7. Engineering administration support during the execution of the work packages, such as responding to RFIs and submittal review and approval. Meetings/Site Visits: Attendance in-person within the Central Texas area by staff based in Plummer Austin office(If'local' staff are unavailable Plummer,or their subconsultants will provide expertise from other Texas offices to an equivalent level of experience and qualifications). Attendance can be virtual if required or preferred by the City.Take meeting minutes and summaries,then share with the City.The Engineer will inform the City on which staff plan to attend the meeting in advance. Administration and Status Reporting: Monthly status reports and invoices will be submitted electronically to City for review and approval. Page 1 of 3 Brushy Creek East Regional WWTP 30 MGD Incomplete Items Work Packages 0982-032-01 Deliverables: Work packages of existing drawings with appendices of supporting data, in pdf format. Subconsultant: The same subconsultants as named in above agreement will be utilized based on their specialty and the required work that needs addressing. If additional subconsultants are required an amendment to this agreement will be required. Time of Completion: The Engineer expects the initial basic services to continue and last for approximately 3 months, until a contractor is ready to perform the work.The schedule for actual construction work completion is unknown currently, but the City expects to complete all priority work by July 2027. Plummer will provide deliverables in a timely manner and respond to City's requests accordingly. Engineer and the City shall agree on reasonable deliverable dates,once specific work is identified, and Engineer has received all required information to begin the task(s). Compensation: Basis of Payment—Hourly Rates Plus Reimbursable Expenses City shall pay Engineer for Services as follows: 1. An amount equal to the monthly cumulative hours charged to the Project by each class of Engineer employees times standard hourly rates for each applicable billing class, plus reimbursement of monthly expenses incurred in connection with providing the Services and Engineer consultants'charges, if any.This also applies to all subconsultants hours. 2. Engineers Standard Hourly Rates are attached as Exhibit D (including subconsultants). 3.The total compensation for services and reimbursable expenses will be agreed in each task order set forth by the City, under this agreement a maximum combined total of not to exceed$100,000 shall be authorized. Insurance: See attached certifies of insurance for Prime and subconsultant Engineer, Exhibit E. Page 2 of 3 Brushy Creek East Regional WWTP 30 MGD Incomplete Items Work Packages 0982-032-01 LIST OF ASSUMPTIONS The following assumptions were used when developing the scope of service and estimating the compensation to Engineer: 1. No design work and construction services work is included in the above-mentioned scope of services [Exhibit B]. 2. All previous calculations, sizing, materials and equipment specifications / suitability have been performed and are not required to be reassessed as part of this scope of work. 3. The following professional services are not included in this phase of work: Geotechnical investigations, environmental assessments, architectural design, and subsurface utility investigations. 4. The list of incomplete work which the Engineer is to assess, and package is attached to this agreement as [Attachment 1]. If additional items are requested by the City,then an amendment to this agreement maybe be required. 5. GIS mapping services or assistance with these services are not in the scope of work. 6. Additional effort associated with preparing bid packages or equipment selection for the ongoing 40 MGD/Rehabilitation work is not included. 7. No further cost estimating than already provided AACE Class 3 OPCC. 8. Because the original design is not being modified and the work is being undertaken under emergency circumstances without a public bidding process, it is assumed that re-sealing of the existing drawings and specifications is not required, as this agreement is between the city and the engineer of record. Page 3 of 3 Attachment 1 Discipline Location Area Detail Observation of Correction Needed Status Indicators Needed for Need Estimated Cost Priority Substantial ed for Architectural Blower Blower Door latching mechanism missing throw at top of Door#502C.See Yes Yes Priority 2 $1,400.00 Building Building Figure 8. liArchitectural Blower Blower Doors 501A and 502A do not close properly.Figure 9 and Figure 10 Yes Yes $30,000.00 Priority 2 Building Building Architectural Blower Blower Door 501A.See Figure 5.Weatherstripping needs to be installed. Yes Yes Priority 2 Building Building Architectural Blower Blower Door 501A.See Figure 5.Door does not close properly. Yes Yes Priority 2 Building Building Architectural Blower Blower Exterior stone veneer grout shows signs of cracking.See Figure 29- Yes Yes Priority 3 Building Building Figure 30.Provide and install color-matching sealant at affected $300.00 locations to address cracking. Architectural East Electrical East Electrical Door 1600A.SeeFigure 1 57,Figure 59 Yes Yes Priority 2 Building Building $6,000.00 Architectural East Electrical East Electrical Door 1600A.Install threshold. Yes Yes Priority 2 Building Building Architectural East Electrical East Electrical Door 1600A.Finish installing Door hardware. Yes Yes Priority 2 Building Building Architectural North North Sealant at scuppers does not match color of roof.See Figure 36. Yes Yes Priority 3 Electrical Electrical $200.00 Building Building Architectural North North/East Roof material has not been applied per Specification Section 07 52 Yes Yes Priority 1 Electrical and Central 16,3.09.See $350,000.00 Building Electrical Figure 35-Figure 38. Building Architectural North North Extensive loss of mineral granules near scuppers.See Figure 35- Yes Yes Priority 1 Electrical Electrical Figure 38. Building Building Architectural North North Door 1602A.SeeFigure 1 Yes Yes Priority 2 Electrical Electrical $250.00 Building Building Architectural North North Door 1602A.Install.weatherstripping. Yes Yes Priority 2 Electrical Electrical Building Building Architectural North North Finish installing door hardware at Door 101 B.See Figure 44-Figure Yes Yes Priority 2 Electrical Electrical 45. $4,500.00 Building Building Architectural Blower Blower Standing water observed on roof. Yes Yes Priority 1 Building Building Architectural Blower Blower Roof seam sealant is cracked and separating throughout. Yes Yes Priority 1 Building Building Architectural Blower Blower Cracking observed in stone at ladder bolt. Yes Yes $1,200.00 Priority 1 Building Building Architectural Blower Blower Steel angle at corner does not conform to Detail 2/A-1903;gap Yes Yes Priority 1 Building Building between stone and angle to be sealed to match adjacent conditions(not filled with concrete). $1,500.00 Architectural North North Standing water observed on roof. Yes Yes $2,500.00 Priority 1 Electrical Build Electrical Building Architectural North North Punctures in roofing require proper repair Yes Yes $3,500.00 Priority 1 Electrical Build Electrical Building Architectural North North Missing stone at building corner Yes Yes $1,100.00 Priority 2 Electrical Build Electrical Building Architectural North North Cracking in stone at Door 1602Alamb Yes Yes $1,000.00 Priority 3 Electrical Build Electrical Building AZ, Architectural North North Threshold missing recessed pocket for door throw. Verification Yes Yes Priority 2 Electrical Build Electrical Required $1,000.00 Building Architectural North North Threshold not installed. Verification Yes Yes Priority 2 Electrical Build Electrical Required $1,000.00 Building Architectural East Electrical East Electrical Standing water observed on roof. Yes Yes $3,500.00 Priority 1 Building Building Architectural East Electrical East Electrical Ladder bolts are not properly secured;washers/shims required Yes Yes $2,500.00 Priority 1 Building Building Architectural East Electrical East Electrical Railings and stairs remain uninstalled. Yes Yes $6,000.00 Priority 1 Building Building Civil Sludge Sludge Finish testing 12"drain between MH 15 and 43. Yes Yes Priority 2 receiving receiving $5,000.00 station station Civil Site wide Site wide Complete Final Paving Yes Yes $425,000.00 Priority 3 Civil North Swale North Swale Complete Swale on North end of site. Yes Yes $10,000.00 Priority 3 Civil UV 2 UV 2 Install sidewalk around east electrical building. Yes Yes $5,000.00 Priority 3 Civil UV 2 UV 2 Install fencing around east end of UV2. Yes Yes $2,000.00 Priority 1 Electrical Relift Transfer Relift Transfer Local control station communications conductor currently run in Yes Yes Priority 3 Pump Pump same conduit as power conductors.***Retift pump work was not needed.A credit is needed for the VFD in the reuse pump station ' $ 100,000.00 electrical building MCC that was not submitted/installed and the wiring that was not pulled and terminated. Electrical Relift Transfer Relift Transfer Motor thermostat not wired.***Relift pump work was not needed. Yes Yes Priority 3 Pump Pump A credit is needed for the VFD in the reuse pump station electrical building MCC that was not submitted/installed and $ 2,500.00 the wiring that was not pulled and terminated. Electrical Relift Transfer Relift Transfer Early break contacts from disconnect switch not wired.**"Relift Yes Yes Priority 3 Pump Pump pump work was not needed.A credit is needed for the VFD in the reuse pump station electrical building MCC that was not $ 2,500.00 submitted/installed and the wiring that was not pulled and terminated. Electrical Sludge Storage Sludge Control panels were shown to be located beneath the blower Yes Yes None None Blowers Storage canopies,confirm okay to have overhead exposure.***FNI Blowers clarified this and it is okay.Remove from list. Electrical Sludge Storage Sludge Blower 3 has a different,large junction box for the conduit to the Yes Yes None None Blowers Storage north of the blower whereas the other blowers have full length Blowers flexible conduit.***FNI clarified this and it is okay.Remove from list. Electrical Sludge Storage Wire Labeling Verify blower labeling and wiring match.The numbering is different Yes Yes Priority 3 Blowers than plans.`"'Update nameplates on front of Blowers. $1,000.00 Electrical ABT 3 ABT 3 Lightning protection system not completed/missing UL master Yes Yes $20,000.00 Priority 1 label. Electrical ABT 3 ABT 3 Strain relief for mixers missing.Many of the hooks that were Yes Yes Priority 1 installed have been $20,000.00 pulled out of the walls.A more robust solution is needed. Electrical ABT 3 ABT 3 Provide 3rd party testing and startup for equipment. Yes Yes $50,000.00 Priority 1 Electrical Aeration General Grounding needed at the southwest corner Yes Yes $3,500.00 Priority 1 Basins Electrical Aeration Aeration No lightning protection system installed. Yes Yes $50,000.00 Priority 1 Basins Basin Electrical Aeration Aeration ABT1 mixers do not have strain relief connectors for the mixer Yes Yes $20,000.00 Priority 1 Basins Basin cable. Electrical Aeration Aeration Anaerobic Mixer disconnect switches have loose and unsupported Yes Yes Priority 1 Basins Basin conduit.Seal off $5,000.00 fitting missing on conduits in these areas. Electrical Alum Storage&Lightening Grounding needs completion and lightening protection Yes Yes Priority 1 Feed Protection $15,000.00 System Electrical Sludge Pump BFP Feed Local control panel 5 lacking label/tag. Yes Yes Priority 3 Station Pump Station $10,000.00 Electrical Blower Electrical LS-2 Alternating Panel has wire pulled to cabinet 2022-RWP-2101 Verification Yes Yes Priority 1 Building and others,but Alterman did not terminate in the panel(s). Prime Required design is LS-2 Panel specifies connection,but Alterman cites Plummer or Eaton drawing as not connecting,so didn't connect. Needs to be connected. Floats not working properly,so alternating panel(emergency float nanell has h•en off for annrnximately 1 sear $50,000.00 Electrical Blower Electrical Main Huber control panel0320-MCP-1001 has never functioned Yes Yes Priority 1 Building properly since installation.Always some form of alarm messaging. Needs to be resolved and function properly. $50,000.00 Electrical Blower Electrical LS-2 Alternating panel has never been tested/used. Yes Yes $750.00 Priority 1 Building Electrical Blower Electrical Main Huber control panel 0320-MCP-1001 has never functioned Yes Yes Priority 1 Building properly since installation. Always some form of alarm messaging. Needs to be resolved and function properly. $50,000.00 Electrical Chemical Chemical 2 fixtures mounted to ceiling should be wall mounted near tanks. Yes Yes $3,000.00 Priority 3 Building Storage Electrical Chemical Chemical Heat trace for chemical piping missing. Yes Yes $6,000.00 Priority 1 Building Storage Electrical Chemical Chemical Heat trace for the eyewash station missing. Yes Yes $5,000.00 Priority 1 Building Storage Electrical East Electrical East Electrical Mixer VFD Gutter box(East Electrical Bld)has wires spliced with Yes Yes Priority 3 Building Building wire nuts.Contract $5,000.00 documents state no splices are to be permitted. Electrical East Electrical Interior Install Cover.See Figure 60. Yes Yes Priority 3 Building $500.00 Electrical East Electrical Interior Finish installing wiring or cap off conduit.See Figure 60. Yes Yes Priority 3 Building $1,000.00 Electrical General/All All Areas Multiple locations:the number of conductors and size conductors Yes Yes Priority 3 Areas spliced with wirenuts is not allowed by the manufactured product. At final walkthrough,the contractor wilt be required to remove $20,000.00 Electrical General/All All Areas UL Master Label for Lightning Protection Yes Yes $500.00 Priority 1 Areas Electrical General/Alt All Areas Manholes around the Site.The top concrete lid of the manholes is Yes Yes Priority 1 Areas not aligned with the ring.This creates tight access to enter the manholes.These need to be aligned with one another.We found a junction box with a wire splice inside a manhole.Splicing is not permitted for these types of circuits,and underground splices like this are a major issue.This is dangerous as manhole can fill with water,shorting out the splice and potentially damaging electrical and process equipment.The manholes are dirty with debris,soil, trash,etc.The cable racks do not currently support wire and are missing insulators.Several wires are pulled tight and not trained around the walls as specified.There are manholes where circuits are routed in a common conduit instead of seperated per the drawings.I do not know what the contractor did since they did not follow the drawings. $150,000.00 Electrical ILS 2 ILS 2 Corrosion Found inside control/power panel.Terminal blocking, Yes Yes Priority 1 conductors and backplanes will not be approved in this state.Seal off fittings missing.Grounding inside panel insufficient.Grounding bar is needed. $500.00 Electrical EMH/IMH EMH EMH-56:Ground rod to be welded,all grounds bonded.Lid is offset, Yes Yes Priority 1 Manholes new ramneck needed.Conductor insulators missing. $3,500.00 Electrical EMH/IMH EMH EMH-67:Remove conductors from floor.Lid offset,new ramneck Yes Yes Priority 1 Manholes needed.Missing ground rod and bonding. $3,500.00 Electrical EMH/IMH EMH EMH-69:Grounding missing.Cleanup debris. Yes Yes Priority 1 Manholes $2,000.00 Electrical EMH/IMH EMH EMH-71:Missing ground rod.Cleanup debris.Lid offset,new Yes Yes Priority 1 $4,500.00 Manholes ramneck needed. Electrical EMH/IMH EMH EMH-60:Ground missing.Cleanup debris. Yes Yes Priority 1 Manholes $3,500.00 Electrical EMH/IMH EMH EMH-59:Lid offset,new ramneck needed.Splice present,splices Verification Yes Yes Priority 1 Manholes notpermitted.Install ground rod.Cleanup debris. :•uired $3,500.00 Electrical EMH/IMH EMH EMH-60:Conduit not flush to watt.Ground rod missing.Missing Yes Yes Priority 1 Manholes insulators.Conductor arms broken.Remove conductors from floor. $3,500.00 Electrical EMH/IMH EMH EMH-70:Missing ground rod.Clean debris. Verification Yes Yes Priority 1 Manholes Required $3,500.00 Electrical North Interior Grounding Verification Yes Yes Priority 1 Electrical Required $3,000.00 Building Electrical Plant Plant Multiple locations:the number of conductors and size conductors Yes Yes $ 25,000.00 Priority 3 spliced with wirenuts is not allowed by the manufactured product. At final walkthrough,the contractor will be required to remove multiple covers to expose conductor splices to verify they have been corrected. Electrical Plant Plant UL Master Label for Lightning Protection. Yes Yes Priority 1 Electrical PTU PTU Heat trace along grit lines not properly installed.Multiple wraps Yes Yes Priority 1 around valve bodies not complete.Coordinate with heat trace $5,000.00 manufacturer. Electrical PTU PTU Lightning protection system not completed/missing UL master Yes Yes $5,000.00 Priority 1 label. Electrical PTU PTU 3rd Party Testing Yes Yes Priority 1 Electrical PTU PTU Permanant Labels need to be installed for the following:Grit Pump Yes Yes Priority 3 Disconnects Termination Cabinets Slide Gate disconnects and E-Stop $1,250.00 Electrical PTU PTU Ductbank 56(Sheet E-121)seemingly missing three 1"Spare and Yes Yes Priority 3 two 2"Spare conduits.Contractor needs to label spare conduit and install missing conduits. $30,000.00 Electrical PTU PTU Pole light west of Screen 1 missing. Yes Yes $8,500.00 Priority 1 Electrical PTU PTU Pole light east of grit chamber 4 missing.Contractor to provide pole Yes Yes Priority 1 fight at north stairwell. Electrical PTU PTU Heat trace circuits are wired temporarly to 120V receptacles.Heat Yes Yes Priority 1 $5,000.00 trace to be wired per contract. Electrical PTU Upper Grit The feed pipe have clamps to support the grounding wire but the Yes Yes Priority 3 Level Dewatering clamps are metal-to metal with the exterior face of the pipe.This has caused damage to pipe coating.Repair coating and provide pad between clamp and pipe Electrical RAS/WAS-3 Disconnect Several conductors inside the RAS and WAS disconnect switches -., -j Yes Yes $1,500.00 Priority 1 , Switches had nicks in the copper wiring. Electrical RAS/WAS-3 Heat Trace Hose bib piping not heat traced. Complete Yes Yes $4,000.00 Priority 2 Electrical RAS/WAS-3 Heat Trace Heat trace routed on WAS pump body.Heat trace should not be ,Comple Yes Yes Priority 1 $3,500.00 installed exposed.Remove from pump body. Electrical RAS/WAS-3 Heat Trace Heat trace routed within conduit.Heat trace should be routed to ' Compl • Yes Yes Priority 1 splice kit then XHHW routed within conduits. $3,000.00 Electrical RAS/WAS-3 Arc Flash Arc flash labels needs to be added.Conduit tags are missing. .•'.t Comple Yes Yes Priority 1 Label Electrical RAS/WAS-3 Heat Trace No heat trace thermostats observed. Not Complete Yes. Yes $4,500.00 Priority 1 _ Electrical RAS/WAS-3 Heat Trace Heat trace installed on valve bodies incorrectly.Install per Not Comple,!; Yes Yes Priority 1 $4,000.00 manufacturer's recommendations. Electrical RAS/WAS-3 Flow Meter Substitute flow meter does not have any power?See electrical CompletL Yes Yes Priority 1 punchlist. Electrical RAS/WAS-3 Hot Box Heat box and power socket not wired in,box has no heat and risks i Complete Yes Yes $1,700.00 Priority 1 freezing. Electrical Scum Pump Scum Pit PLC has no programing. , Complete ' Yes Yes Priority 1 Station Electrical Scum Pump Scum Pit Heat trace missing thermostat and exposed. i.Complete Yes Yes Priority 1 Station $1,000.00 Electrical Scum Pump Scum Pit Level transducer has been reading incorrectly.Conduit feeding .`Complete Yes Yes Priority 1 Station transducer is damaged. Electrical Scum Pump Scum Pump PLC at scum pump needs programming :-')Complete Yes Yes Priority 1 Station Station "'. Electrical Scum Pump Scum Pump Level transfucer not reading correctly Yes Yes Priority 1 Station Station Electrical Site Lighting Light Poles Light Pole Skirt Bases Yes Yes $1,000.00 Priority 3 Electrical Site Lighting Light Poles Light Pole Hand Hole Covers Yes Yes $1,000.00 Priority 3 Electrical Site Lighting Light Poles Repair Broken Pipe in Keeley Area Yes Yes Priority 2 Electrical Site Lighting Site Plan-B 2 Lights are currently not working and need to be corrected. Yes Yes Priority 2 (Final Clarifiers 1-4) Electrical Site Lighting Site Plan-B Perform testing on existing light pole that has not been tested. Yes Yes Priority 2 (Transfer Pump Station) Electrical Site Lighting Site Plan-D 9 Lights are currently not working and need to be corrected. Yes Yes Priority 2 (SST 1&2) Electrical Site Lighting Site Plan-F 3 Lights are currently not working and need to be corrected. Yes Yes Priority 2 (Alum Storage) Electrical Sludge Storage SST 1 Pull box on south side of Sludge Storage Blower Canopy 1 has Yes Yes Priority 3 spliced wires.These wires are also run in single conduit,drawings show individual conduit for each circuit.Repull wire so that no splices are present and install new wire in individual conduits. • $4,000.00 Electrical Sludge Storage Sludge Confirm the control panel locations and wiring are depicted _ Yes Yes Priority 3 Blowers Storage correctly in the contractor as-builts since the control panels are not Blowers installed in the locations as shown on the plans.Apply physical labels/tags to all panels. ., Electrical SST 2 Tags Tag at all circuits Complete Yes Yes $2,500.00 Priority 3 Electrical UV 1 UV 1 Spare conduits need to be labeled. Complete Yes Yes $1,000.00 Priority 3 Electrical UV 2 UV 2 3rd Party Testing Complete_: Yes Yes Priority 1 Electrical ABT 1 Aeration Basin 3 DO transmitter conduit is loose. '.h Compl_,,, Yes Yes $250.00 Priority 2 Basin Train 1 _ . Electrical ABT 2 Aerobic Zone Electrical conduit line without any equipment connection ',Compl:tl Yes Yes $1,000.00 Priority 2 Electrical ABT 2 Aeration PLC rack receptacles wired through PLC cabient.This is not '''Complete ' Yes Yes $1,250.00 Priority 2 Basin Train 2 allowed. . Electrical ABT 3 Electrical Electrical wiring is disconnected and sitting on concrete in multiple )Complete Yes Yes $1,250.00 Priority 2 places. Electrical ABT 3 AB 3 Electrical conduit is mounted to foul air piping support Compld,t.; Yes Yes $1,000.00 Priority 2 Electrical ABT 3 AB 3 Overload not installed .,.)._Complete ' Yes Yes $4,500.00 Priority 2 Electrical Aeration Aeration Anoxic Zone DO analyzer conduits longer then needed and are not ,i Complex:' Yes Yes Priority 2 Basins Basin properly ` $35,000.00 supported. Electrical Aeration Aeration Several lighting and receptacle are loose and are a place for water Yes Yes Priority 2 Basins Basin ingress.The plant has requested that this not be deferred to the final punchlist since they use those circuits to maintain and operate the plant. $4,500.00 Electrical Sludge Pump BFP Feed Sump pumps wires and junction box exposed. Yes Yes Priority 2 Station Pump Station $2,500.00 Electrical Sludge Pump BFP Feed Motor wiring flex conduit is inconsistent.Needs attention,see Yes Yes Priority 2 Station Pump Station photos. $2,500.00 Electrical Blower Blower Room Electrical conduit leading to equipment is disconnected,exposing Yes Yes $50,000.00 Priority Building wiring Electrical Central Central Remove cardboard within MCC-SST. Yes Yes Priority 2 Electrical Electrical $1,250.00 Building Building Electrical Dewatering North BFPs New control panels are lacking sludge feed gpm readout. Yes Yes Priority 2 Building $5,000.00 Electrical Dewatering North BFPs Wiring and E-stop fixes/adjustments are in process with Alfa Laval Yes Yes Priority 2 Building per Javi.Need confirmation of corrections and completeness in writing from contractor. Electrical Dewatering Hopper 2 Level instrument signals are interfered by support strut and beam. Yes Yes Priority 2 Building Need to relocate to better Location for better readings of sludge level without conflicts. $5,000.00 Electrical Dewatering Hopper 2 Wires exposed. Yes Yes $5,500.00 Priority 2 Building Electrical Dewatering Dewatering Hoppers overflowing.Level is not being measured so system Yes Yes Priority 2 $10,000.00 Building Building cannot run in auto. Electrical Dewatering Dewatering New press control panels no operating.City believes cable that Yes Yes Priority 2 Building Building was to be run to the $2,500.00 control panels was terminated in PLC 1350-PLC-1001. Electrical Dewatering Dewatering Signals for hopper levels not wired to displays or control panels. Yes Yes Priority 2 Building Building Hopper currently cannot run in Auto. Electrical Dewatering Lower Level Electrical wiring and support attached to concrete barrier Yes Yes Priority 2 Building $5,000.00 Electrical Dewatering Lower Level Wiring not connected at compressor,due to no breaker Yes Yes $4,500.00 Priority 2 Building Electrical Filters Building Filters Circuit breaker used is not GFEP. Yes Yes $3,000.00 Priority 1 Electrical PTU PTU Conduit for grounding of 350-SG-1101 too low,needs to beat Yes Yes Priority 2 minimum of 7'-0"AFF. Electrical PTU PTU Level transducers at PT are set at approx.81"but zero set point is Yes Yes Priority 2 set to 81.5".Program need to be adjusted so flow can be calculated correctly. Electrical RAS/WAS-3 Float&Pump Float and pump wiring for sump pumps needs properly securing per Yes Yes Priority 2 standard details $3,500.00 Electrical RAS/WAS-3 Flow Meter All sockets in flow meter control panels missing front face(check Yes Yes Priority 2 electrical punchlist) $3,500.00 Electrical Sludge Storage Sludge Exposed wires need to be replaced.Wiring will not be accepted Yes Yes Priority 2 Blowers Blowers Electrical Sludge Storage SST 1 Install seals in seal off fittings before equipment startup. Yes Yes Priority 2 Electrical Sludge Storage Sludge Small blowers panels,lots of exposed wire,missing junction box Yes Yes Priority 2 Blowers Storage cover. Blowers Electrical Sludge Storage Sludge Confirm the thermostats for each of the large blowers and small Yes Yes Priority 2 Blowers Storage blowers are installed and wired correctly.There was some Blowers discussion of unknown terminations or signal wiring locations. $2,500.00 Electrical Sludge Storage Sludge Air flow meters(typ 3):Sensor wire hung without clips/support, Yes Yes Priority 2 Blowers Storage excess wire just looped around strut.Susceptible to damage. $2,500.00 Blowers Electrical Thickening Thickening Conduits to be sealed. Yes Yes $1,600.00 Priority 2 Building Building Electrical UV 1 UV 1 Outlets have no power(check breakers) Yes Yes Priority 2 Electrical Aeration Aeration Aluminum conduit poured in the concrete sidewalk and directly Yes Yes Priority 3 Basins Basin buried below grade.This conduit must be PVC coated conduit when passing through concrete $35,000.00 Electrical Blower Blowers 3&4 Conduit running along wall in place of future Blower LCPs.Conduit Yes Yes Priority 3 Building /Mechanical needs rerouting(see electrical for further details) $40,000.00 Electrical EMH/IMH IMH IMH-56:Lid is offset,new ramneck needed.Pullstrings for spare Yes Yes Priority 3 Manholes conduits to be added.Conductor insulators missing. $3,500.00 Electrical EMH/IMH EMH EMH-44:Lid is offset,new ramneck needed.Missing conductor Yes Yes Priority 3 Manholes insulators.Debris and dirt is excessive,remove dirt and debris from manhole. $3,500.00 Electrical EMH/IMH EMH EMH-45:Lid is offset,new ramneck needed.Missing conductor Yes Yes Priority 3 Manholes insulators.Debris and dirt is excessive,remove dirt and debris from manhole. $3,500.00 Electrical EMH/IMH IMH IMH-34:Missing insulators.Lid is offset,new ramneck needed. Yes Yes Priority 3 Manholes Debris needs to be removed. $1,000.00 Electrical EMH/IMH EMH EMH-47:Lid is offset,new ramneck needed.Missing insulators. Yes Yes Priority 3 Manholes $2,500.00 Electrical EMH/IMH EMH EMH-12:.Remove bracket blocking spare conduit.Conductor arms Yes Yes Priority 3 Manholes loose,in the way.Conductors resting on the floor. $2,500.00 Electrical EMH/IMH IMH IMH-36:Lid is offset,new ramneck needed.Missing insulators. Yes Yes Priority 3 $1,500.00 Manholes Clean debris. Electrical EMH/IMH EMH EMH-49:Lid offset,new ramneck needed. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH IMH IMH-37:Lid offset,new ramneck needed,missing insulators. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH EMH Resuse EMH:Controls from HOA in power conduit. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH IMH Resuse IMH:Not used when called for. Yes Yes $3,500.00 Priority 3 Manholes Electrical EMH/IMH IMH IMH-38:Missing insulators.Lid offset,new ramneck needed. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH IMH IMH-67:Clean debris.Remove from conductors from floor.Lid Yes Yes Priority 3 Manholes offset,new ramneck needed. $3,500.00 Electrical EMH/IMH EMH EMH-27:Manhole was to be demo'd. Yes Yes Priority 3 Manholes $250.00 Electrical EMH/IMH IMH IMH-69:Missing insulator.Cleanup debris. Yes Yes Priority 3 Manholes $1,500.00 Electrical EMH/IMH EMH EMH-18:Removeconductors from floor,properly fasten to arms. Yes Yes $1,500.00 Priority 3 Manholes Electrical EMH/IMH IMH IMH-71:Missing sump cover.Missing insulators. Yes Yes Priority 3 Manholes $500.00 Electrical EMH/IMH EMH EMH-65:Lid offset,new ramneck needed. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH IMH IMH-40:Missing insluators. Yes Yes Priority 3 Manholes $3,500.00 lliiiiIIII Electrical EMH/IMH IMH IMH-61:Cleanup debris.Missing inuslators. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH EMH EMH-58:Missing insulators.Lid offset,new ramneck needed. Yes Yes Priority 3 Manholes $3,500.00 Electrical EMH/IMH IMH IMH-42:Missing insluators.Lid is offset,new ramneck needed. Yes Yes Priority 3 Manholes _. $3,500.00 lied Electrical EMH/IMH IMH IHM-43:Lid offset,new ramneck needed.Insulators missing. Yes Yes Priority 3 Manholes $4,500.00 Electrical EMH/IMH IMH IMH-57:Missing pullstrings for spares.Provide missing spare m Yes Yes Priority 3 Manholes conduits.Lid is offset,new ramneck needed. $3,500.00 Electrical EMH/IMH IMH IMH-60:Conduits not flush.Missing insulators.Cleanup debris. Yes Yes Priority 3 Manholes Patch exposed rebar. $3,500.00 Electrical EMH/IMH EMH EMH-53:Missing insulators. Yes Yes $3,500.00 Priority 3 Manholes Electrical Plant Plant Manholes around the Site The top concrete lid of the manholes is Yes Yes Delete Delete not aligned with the ring.This creates tight access to enter the manholes.These need to be aligned with one another.We found a junction box with a wire splice inside a manhole.Splicing is not permitted for these types of circuits,and underground splices like this are a major issue.This is dangerous as manhole can fill with water,shorting out the splice and potentially damaging electrical and process equipment.The manholes are dirty with debris,soil, trash,etc.The cable racks do not correctly support wire and are missing insulators.Several wires are pulled tight and not trained around the walls as specified.There are manholes where circuits are routed in a common conduit instead of separated per the drawings.I do not know what the contractor did since they did not follow the drawings. HVAC Blower Blower Room HVAC needs servicing Yes Yes Priority 2 Building HVAC Blower Roof RTU condensate piping is routed to downspout rather than dry well. Yes Yes Priority 2 Building See Figure 1. HVAC Blower Interior RTU-1 fan has noisy operation.Manufacturer has been on site and Yes Yes Priority 2 $30,000.00 Building confirmed a replacement is needed. HVAC Central Interior None of the wall mounted AC units have condensate piping.See Yes Yes Priority 2 Electrical Figure 6. $13,500.00 Building HVAC Central Interior Thermostats"B"and"A"are not functioning.See Figure 8. Yes Yes Priority 2 Electrical $4,400.00 Building HVAC East Electrical Roof RTU condensate piping is routed to downspout rather than dry well. Yes Yes Priority 2 Building See Figure 9. $6,000.00 HVAC North Roof RTU condensate piping is routed to downspout rather than dry well. Yes Yes Priority 2 Electrical See Figure 4. Building Mechanical ABT 1 Aeration Cable hooks that were installed are not sufficient for strain relief. Yes Yes Priority 1 $3,618.00 Basin Train 1 Many of the hooks have broken and are missing Mechanical ABT 2 General ARV plate covering doesn't have any identification tag or labeling Yes Yes Priority 2 (Mud Valve Cover-CM) $80.00 Mechanical ABT 2 General Equipment wiring is not properly secured Yes Yes $50.00 Priority 1 Mechanical ABT 3 Anerobic and Submersible mixers haven't been installed Yes Yes Priority 1 Anoxic Zones Mechanical ABT 3 ABT 3- Heat trace circuit left sitting out and not wired in. Yes Yes $412.00 Priority 1 Electrical Mechanical Aeration General Many mixers were installed with galvanized cables Yes Yes Priority 1 Basins Mechanical Alum Storage&Alum Feed The safety shower was not functioning and did not have any heat Yes Yes Priority 2 Feed Building tracing. Heat tracing was being installed at the time of the $100.00 System inspection. Mechanical Alum Storage&Alum Feed Housekeeping items need to be addressed before final punchlist. Yes Yes Priority 2 Feed Building System Mechanical Sludge Pump BFP Feed Missing pipe labels Yes Yes Priority 2 Station Pump Station $1,000.00 Mechanical Sludge Pump BFP Feed Contractor to provide surveyed as-builts for 6"pipes leaving the Yes Yes Priority 3 Station Pump Station pump station and traveling to the Dewatering Building.As-builts shall include which pump is piped to which BFP and where the pipe alignments differ from the original contractor drawings. $3,200.00 Mechanical Sludge Pump BFP Feed Install valve tags,equipment name plates,and pipe labels.Paint Yes Yes Priority 2 Station Pump Station and label exposed NPW and sump pump discharge PVC. $1,125.00 Mechanical Sludge Pump BFP Feed Progressive cavity pumps are missing equipment pads(house Yes Yes Priority 3 Station Pump Station keeping pads). $10,000.00 Mechanical Sludge Pump BFP Feed Insulation on north end of common discharge header is missing. Yes Yes Priority 1 Station Pump Station $1,100.00 Mechanical Sludge Pump BFP Feed Confirm in writing that start-up comments from SD 388 have been Yes Yes Priority 2 Station Pump Station addressed. New guards needed on 2 units. Seal pressure gauges not working(inspect,and flush...could be olu66ed)Run dry alarm not functioning. $480.00 Mechanical Chemical Chlorine Insulate emergency eye wash station(repair leak at the stainless Yes Yes $275.00 Priority 1 Building Building fitting) Mechanical Chlorine Chlorine Signs located on doorways and tanks are paper or spray painted. Yes Yes Priority 1 System Building Signs and labels need to be permanent or stenciled per Section 10 $563.00 09 00. Mechanical Chlorine Chlorine All chemical piping,including piping on the skids,needs to have Yes Yes Priority 1 System Building correct paint with banding.Sodium Bisulf needs yellow banding $1,000.00 Mechanical Chlorine Chlorine Inside safety shower potable pipe requires to be painted light blue Yes Yes $400.00 Priority 1 System Building Mechanical Clarifiers Clarifier 5/ Solenoid valve 0600-SV-3101 is not working Yes Yes $1,200.00 Priority 2 Mechanical& Ele Mechanical Clarifiers Clarifier 5/ Meter vault is not sealed and has dirt water getting in,needs Yes Yes Priority 3 $940.00 Mechanical cleaning out and new lids to secure. Mechanical Clarifiers Clarifier 5/ Chlorine Pipe required to be coated with yellow safety coating. Yes Yes $1,000.00 Priority 2 Mechanical Mechanical Clarifiers Clarifier 6/ Chlorine Pipe required to be coated with yellow safety coating. Yes Yes $1,000.00 Priority 2 Mechanical Mechanical Clarifiers Clarifier 6/ Chlorine Pipe needs adjusting so chlorine falls into tough during full Yes Yes Priority 1 Mechanical rotation(appears spout is too long which creates discharge onto metal structure). $6,250.00 Mechanical Clarifiers Final Clarifier Insulation on was removed from 2"NPW piping.Insulation to be Yes Yes Priority 1 $7,700.00 1-4 reinstalled at this portion of piping Mechanical Filters Building Cloth Media The guardrail gate located above Cloth Media Disc Filter 2 is Yes Yes $1,100.00 Priority 1 Disc Filter 2 missing. Mechanical Filters Building Piping Piping is missing heat trace and the pipe jacketing has damages. Yes Yes $1,100.00 Priority 1 Mechanical Filters Building Filters Heat trace not installed per specifications.Exposed heat trace Yes Yes Priority 1 present.Heat trace terminated to wire using wire nuts inside a pullbox.No thermostat present. $200.00 Mechanical ILS 2 ILS 2 Pump has pressure issues Yes Yes $23,175.00 Priority 1 Mechanical ILS 2 Pump#3 Pump#3 needs to be cleaned and placed back into service Yes Yes $11,587.00 Priority 1 Mechanical ILS 2 Pump#1 Pump#1 needs to be sent back to shop for known issues Yes Yes $85,000.00 Priority 1 Mechanical ILS 2 Pump#5 Pump#5 needs to be cleaned and placed back into service Yes Yes $11,587.00 Priority 1 Mechanical ILS 2 Odor Control Missing vacuum relief damper on top of lift station,see sheet M- Yes Yes $2,060.00 Priority 3 201. Mechanical Odor Control Biotower Repair coating scratch on the southeast side of the biotower Yes Yes $100.00 Priority 2 sidewall. Mechanical Odor Control NPW Yard Missing yard hydrant Yes Yes Priority 3 Piping Mechanical PTU Upper Level Damage to FRP cover plate,required patch repairs.(Multiple Yes Yes Priority 3 locations) Mechanical PTU Lower Level Insulation removed from Grit Piping in various places Yes Yes $125.00 Priority 1 Mechanical PTU Lower Level Basket strainer rmoved from NPW Pipe,unsure if this is spare or Complete Yes Yes ? only one? Mechanical PTU Bug screen missing on vent caps for classifiers „'F- Yes Yes $725.00 Priority 2 Mechanical PTU-Odor Upper Level Many of the foul air dampers which are beneath the PTU channel ;Complete Yes Yes ? Control covers were discovered to be fully closed.Confirm all dampers are operable.Set all dampers to 50°/0 o.en. $480.00 Mechanical PTU-Odor Upper Level The 6"and 8"foul air drops on the northeast face of the PTU(in Yes Yes Priority 3 Control between the 18"and 20"drops)just end with a cut pipe and are lacking a manual balancing damper.See SD 227,contract drawing PIDs,and contract drawingvalve list. $7,000.00 Mechanical PTU-Odor FA Pipe Provide sample ports and plugs for foul air duct. Yes Yes Priority 3 Control $12.00 Mechanical PTU Lower Heat Trace Heat trace wire to be installed on all lower level piping,if not Yes Yes Priority 1 $600.00 Level already installed Mechanical PTU Lower Insulation& Install insulation and jacketing on all exposed piping for DIP Yes Yes $750.00 Priority 1 Level Jacketing Mechanical PTU Upper Foul Air Pipes Did anyone observe the foul air piping and dampers that are Yes Yes ? Level installed beneath the cover system downstream of the grit vortex units Mechanical PTU Upper Compactor Compactor#2 actuator not working Verification Yes Yes Priority 1 Level R=.uired Mechanical RAS/WAS-3 Lower Level Insulation present around all piping but is not present here Yes Yes $1,100.00 Priority 1 Mechanical RAS/WAS-3 Heat Trace Heating and Insulation repairs required on all 4"WAS piping Yes Yes $1,320.00 Priority 1 Mechanical RAS/WAS-3 Valve Valving arrangement is not correct,valves require moving.Isolation Yes Yes Priority 1 Arrangement valves are needed outside the flow meter and check valve. Mechanical RAS/WAS-3 Heat Trace PVC piping outside of cabinet requires heat tracing and insulation. Yes Yes $375.00 Priority 1 Mechanical Scum Pump Scum Pump 30 day testing can begin once SST are online and scum can be Yes Yes Priority 1 Mechanical Scum Pump Scum Pump Confirm flushing valve once pumps are in opertation Yes Yes Priority 1 Station Station Mechanical Scum Pump Scum Pump Require testing reports of the pumps and signoff from Zone Yes Yes Priority 1 Station Station Industries Mechanical Sludge Storage Sludge Large blower area=82.5 dB recorded.Small blower area=85 dB Verification Yes Yes Priority 2 Blowers Storage recorded.Big blowers should be 80 dB and small blowers should be Required Blowers 78 dB per the original preselection bid.Spec says 80 dB max at 5-ft distance.Although there could've been some ambient noise,these recordings exceed the maximum noise level.Confirm the noise- attenuating enclosures are installed correctly to do their job. $240.00 Mechanical Sludge Storage Insulation Air head piping is missing insulation(Note 3,M-1201).Needed to Yes Yes Priority 2 Blowers prevent burns. $2,500.00 Mechanical Sludge Storage Sludge Missing pipe labels Yes Yes Priority 2 Tanks Storage Tanks $375.00 Mechanical Sludge Storage Sludge Missing valve tags Yes Yes Priority 2 Tanks Storage Tanks $250.00 Mechanical Sludge Storage SST 2 Need valve labels for submerged plug valve and flap gate valve. Yes Yes Priority 1 Tanks Submerged plug valve needs open/close indicator on top of $150.00 walkway. Mechanical Sludge Storage Odor Control Foul air pipe missing pressure relief damper.Pressure relief damper erification Yes Yes Priority 3 Tanks also missing from eastern stairs access area. Required $4,120.00 Mechanical SST 2 East Pipes 6"WAS and 8"TWAS missing HTI.Need credit to owner Yes Yes Priority 1 Mechanical UV 1 UV 1 Airline not reconnected after construction in the area Yes Yes $240.00 Priority 2 Mechanical Post Aeration Effluent Missing 4"BFV on drop legs. Yes Yes Priority 1 • Basin Aeration Plan M $1,360.00 840 Mechanical Post Aeration Effluent Missing attachement points for lifting without need for tank drain. Yes Yes Priority 1 Basin Aeration Plan M $20,000.00 840 Mechanical Post Aeration Effluent Missing hand wheel actuators and valve stems. Yes Yes Priority 2 Basin Aeration Plan M $100.00 840/M-841 Mechanical AB-Train 1 Basin 3 Broken diffuser grid section at minimum 5 heads needing Yes Yes $3,219.00 Priority 1 Diffusers replacement Mechanical AB-All Trains All Basins All IMLR piping needs primer and epoxy coating Yes Yes $114,900.00 Priority 1 Mechanical AB-All Trains All Basins Submersible mixers needing repair/installation(14) Yes Yes $48,972.00 Priority 1 Mechanical AB-All Trains All Basins Submersible RCPs needing repair/installation(4) Yes Yes $20,606.50 Priority 1 Mechanical AB-All Trains All Basins LPA pipe supports not installed correctly Yes Yes $6,180.00 Priority 1 Mechanical AB-All Trains All Basins Fixed pipe supports incorrectly installed Yes Yes Priority 2 Mechanical AB-Train 2 Basin x Phosphax analyzer Unit 2 needs recalibration,repair or Yes Yes $1,200.00 Priority 1 replacement Mechanical AB-All Trains All Basins Submersible mixers needing replacement(17) Yes Yes $455,906.00 Priority 1 Mechanical AB-All Trains All Basins Submersible RCPs needing replacement(3) Yes Yes $118,486.00 Priority 1 Mechanical AB-Train 2 Basin 5 Air leak needing investigation and repair Yes Yes $720.00 Priority 1 Diffusers Mechanical AB-Train 3 Basin 11 Mud valve needing repair Yes Yes $768.50 Priority 1 Mechanical Chemical Chemical Level instrument repairs-tank 4 Yes Yes $450.00 Priority 1 Building Tanks Mechanical Chemical Chemical Level instrument repairs-tank 2 Yes Yes $20.00 Priority 1 Building Tanks Mechanical Chemical Chemical Leak investigation and recalibration on tank 1 Yes Yes $240.00 Priority 1 Building Tanks Structural ABT 3 Effluent Scum gate missing(0400-WG-3001) Yes Yes Priority 3 Splitter Box Structural East Electrical East Electrical Complete door installation,including threshold Yes Yes Priority 2 Building Doorway Structural North Interior Both the single and double doors are opening on their own and do Yes Yes Priority 2 Electrical not have any Latching mechanism Building Structural North Interior Double Doors Yes Yes Priority 2 Electrical Building Structural North Interior Roof Deteriorating Yes Yes Priority 1 Electrical Building Structural RAS/WAS-3 RAS/WAS Duct Tape used instead of insulation at this segment of piping. Yes Yes Priority 1 Piping Insulation to be replaced Structural UV 2 UV Channel grating missing along banks. Yes Yes Priority 1 Disinfection M 801 Structural UV 2 UV Stairs missing. Yes Yes Priority 1 Disinfection M 801 Structural Parshalt Flume Effluent Stairs missing and final grading needed. Yes Yes Priority 1 Aeration Plan M- 840/M-841 Structural Parshall Flume Parshall Stairs and stair landing not installed. Yes Yes $7,000.00 Priority 1 Flume M-880 Structural Blower The CMU construction joints have been properly constructed in the Yes Yes Priority 1 Building electrical room.However,six construction joints are missing in the blower room,Figure 30.Due to the nature of the issue and because implementing corrective modifications would be costly and time consuming,the Contractor shall provide an extended warranty for this building in lieu of the proposed modifications. The Contractor shall be responsible for the repair of any CMU cracking attributable to the identified construction deficiencies throughout the extended warranty period. Structural UV Building There are missing railings and stairs around the blower and Yes Priority 1 transformer area and around the west side entrance of the building, Figure 31 and 32 Structural East Electrical Exterior Install missing railings and stairs around the blower and Yes Priority 1 Building transformer area and around the west side entrance of the building, Figure 31 and 32. Exhibit"C" Work Schedule Exhibit C-Priority Incomplete Items from 30 MGD Expansion ID Task Task Name Duration Start Finish Predecessors I Sep•26 I Oct'26 5II Nov'26 I Dec'26 I Jan'27 I Feb'27 I Mar'27 I Apr'27 I May'27 I Jun'27 I Jul'27 0 Mode 30[6 11 312 01271 4I11118I251118 11c4221291 61131211271 3 1101171241311711412112817114211281411111812512 19116123130161131201271411111814 1 fr Project Management 235 days Mon 9/7/26 Fri 7/30/27 i 2 1 Site visits 15 days Mon 9/7/26 Fri 9/25/26 MIN 3 fr Review&assessment of 26 days Fri 9/25/26 Fri 10/30/26 incomplete work list 4 Jr Coorindation with equipment 26 days Fri 9/25/26 Fri 10/30/26 suppliers 5 Jr Work packet production 79 days Tue 9/22/26 Fri 1/8/27 I 6 OP' Review of Pricing 11 days Fri 1/8/27 Fri 1/22/27 I I I 7 * Constructon Admin of packages 146 days Fri 1/8/27 Fri 7/30/27 I l DRAFT Task 111111111111111111111M1111 Project Summary 1 -7 Manual Task L' I Start-only C Deadline G Project: Split Inactive Task Duration-only illikaltallairgillat Finish-only ] Progress Date:Tue 9/8/26 Milestone ♦ Inactive Milestone Manual Summary Rollup External Tasks i?r;5#>08elk:;:`•?.^ Manual Progress Summary ll • Inactive Summary I I Manual Summary • • External Milestone 9 Page 1 Exhibit"D" Fee Schedule Y1 �. PLUMMER .. -..... EXHIBIT D PLUMMER ASSOCIATES, INC HOURLY FEE SCHEDULE 2026 Category Rate Category Rate Administration Engineers/Scientists Al $ 100.00 ESO $ 95.00 A2 $ 110.00 ES1 $ 155.00 A3 $ 125.00 ES2 $ 170.00 A4 $ 145.00 ES3 $ 190.00 ES4 $ 220.00 Category Rate ES5 $ 250.00 CAD Designers ES6 $ 270.00 Cl $ 130.00 ES7 $ 325.00 C2 $ 140.00 ES8 $ 360.00 C3 $ 165.00 ES9 $ 390.00 C4 $ 185.00 C5 $ 210.00 Category Rate Geospatial Category Rate LS1 $ 130.00 Resident Project Representatives LS2 $ 135.00 RR1 $ 140.00 LS3 $ 150.00 RR2 $ 150.00 LS4 $ 175.00 RR3 $ 160.00 LS5 $ 220.00 RR4 $ 180.00 LS6 $ 265.00 LS7 $ 280.00 Category Rate Construction Managers Category Rate CM1 $ 160.00 Telecommunication Designers CM2 $ 170.00 TD1 $ 130.00 CM3 $ 185.00 TD2 $ 140.00 CM4 $ 210.00 TD3 $ 160.00 CM5 $ 230.00 TD4 $ 175.00 CM6 $ 270.00 CM7 $ 320.00 Category Rate CM8 $ 340.00 Professional P1 $ 140.00 Category Rate P2 $ 160.00 Electrical Engineers and Specialists P3 $ 220.00 EE1 $ 155.00 P4 $ 300.00 EE2 $ 170.00 P5 $ 375.00 EE3 $ 195.00 EE4 $ 230.00 Billing rates may be adjusted up to 5 percent annually(at the beginning of each calendar EE5 $ 260.00 year)during the term of the agreement. EE6 $ 300.00 EE7 $ 350.00 A mulitiplier of 1.15 will be applied to all EE8 $ 370.00 direct expenses. EE9 $ 390.00 Fleet vehicles charge at$1,500 per month, $150 per day. raNICHOLS Name Position Hourly Rate Alex Kavanaugh Professional4 $244 Blane McGee Professional 2 $157 Brad Watson Professional 6 $403 David Hunn Professional 5 $366 Greg Gaskie Professional 4 $234 Janet Frantz CAD Technician/Designer 3 $214 John Manning Professional6 $361 John Rinacke Professional 3 $208 Maziar Mandavi Professional4 $266 Michael Schuster Professional 5 $287 Miguel Marroquin Professional 3 $204 These ranges and/or rates will be adjusted annually in February. Last updated 2026. 360022026 ®egis Egis Billing Rate Schedule-2026 Title Rate Principal I $ 348.00 Principal II $ 456.00 Project Manager I (8-10) $ 196.00 Project Manager II (10-12) $ 212.00 Project Manager III (12-15) $ 228.00 Project Manager IV(15-20) $ 282.00 Project Manager V(20-25) $ 293.00 Project Manager VI (25+) $ 315.00 Professional Engineer I (5-8) $ 168.00 Professional Engineer II (8-10) $ 185.00 Professional Engineer III (10-12) $ 206.00 Professional Engineer IV(12-15) $ 217.00 Professional Engineer V(15-20) $ 239.00 Professional Engineer VI (20-25) $ 283.00 Professional Engineer VII (25+) $ 293.00 Engineer in Training I (0-2) $ 130.00 Engineer in Training II (3-4) $ 141.00 Engineer in Training III (5+) $ 147.00 Engineering Technician Entry $ 125.00 Engineering Technician Mid $ 163.00 Engineering Technician Senior $ 196.00 GIS Technician Entry $ 109.00 GIS Technician Mid $ 152.00 GIS Technician Senior $ 174.00 GIS Administrator Senior $ 217.00 CAD Technician Entry $ 98.00 CAD Technician Mid $ 141.00 CAD Technician Senior $ 163.00 CAD Administrator Senior $ 217.00 Planner I (0-5) $ 125.00 Planner II (5-10) $ 174.00 Administrative Specialist I (0-5) $ 76.00 Administrative Specialist II (5-10) $ 87.00 Administrative Specialist III (10-15) $ 98.00 Administrative Specialist IV(15-20) $ 109.00 Administrative Specialist V(20-25) $ 120.00 Administrative Specialist VI (25+) $ 130.00