R-81-401 - 7/28/1981Form 20021 4 10/74
PIPE LINE LICENSE
STRUMENT., executed in duplicate, July ;24 ,:1%1 , WITNESSETH:
The :undersigned Carrier hereby grants, but on solely the herein expressed terms and
ooniitions,��and the undersigned Licensee ( a Municipality & ,
(individual, copartners or corp. state where incorporated
to be addressed attity Hall, 214 E. Main, .Round Rock, Texas 78664 ,
hereby sOdepts-, permission to install, keep, maintain, repair, renew and use for conveying
. sabitary sewage the Licensee's own one certain '' proposed.
(number) (proposed or existing)
continuous line of pVC, pipe ,6- inches in diameter, and appurtenances,
including 12 -inch steel casing,-50:feet long :, herein called Pipe Line, on .
the Caz'riert's property, herein called Premises. Pipe Line will b used to
.`convey sanitary.sewage
TJ3TR
. i'
Pipe Line shall- intersect Carrier's'exieting
• &XIICK at Mile Post 62.68
ht'.of way)Engineer's•Chainage Station 8587 +70'
- •,Williamson.County -, Texas. , atHMEIMPX Round Rock •
(county or parish) (state) (place) .
Approximte4location •of•Pipe;Line is indicated by heavy blue • ' line on
Exhibit; attached hereto ae part hereof.
al 1 Zicensee shall at all times keep Pipe Line. in good state,of.repair. All work by
Liceneee; hereunder •shall be performed in'a safe and •workmanlike m . nner.. Licensee shall
furnish or •do at Licensee's own cost and responsibility any and,all things and when - and
as from - time',, to time required to-accomplish whatsoever - the Licensee attempts or,iis bound
-to do.,atl'anitime hereunder. Licensee. shall adjust Pipe-Line to any physical change air,
made $t e'nyitime •in. any' of Carrier's property; at all times keeping upper surface of Pipe
Line -at, least • five and'ono - half feet below bottomnof rail thereover.
• Licenseei%shall oause Pipe Line, before being used for - anything Inflammable,- to conform •
.'subetant :aljy.to Exhibit •B attached hereto as part hereof. • Saidhings, including:the
time and!.manner of :doing any work,- each shall conform to.the- requirements of Carrier as
well as'f any. State, Federal or Municipal authority. - Carrier may acting for Licensee
furnish' r db,, and Licensee shall nay and bear the cost of, anything which, herein required
of Liceneeeat.any time, either shall not be furnished or done within -ten. days following
Carrier' S. written request therefor or shall be undertaken by'Carrier -at Licensee's request;
and - Lioensee, •o,n'- request. shall in advance deposit with - Carrier the ...estimated cost. thereof. -
If'deposit be less than actual cost, Licensee shall pay the differenee; if more, Carrier
- shall repay difference.
LiCensee when returning - this license'(signed) •shall pay'to Carrier Five Hundred
dollars .for`the license.granted herein. Any other payment shall be made within twenty
days' - ,',following. receipt of bill. Licensee shall pay cost to Carrier for all labor, includ-
ing wageq o4 foremen, cost of f.o.b. Carrier's rails plus.freight at tariff rates
to poloti of use, phis taxes -ani usual railroad.additivee. No provisions of this paragraph,
nor apprbval by Carrier of any of Licensee's Undertakings, shall relieve Licensee of -any
responsibility -or liability.
2. ' Licensee agrees to -(a) indemnify and save harmless the'Carrier from and against
all olaiMe suits, damages, costs (including attorneys' fees), looses and expenses, in any
manner res4ting from or arising out. of or in oonnection with the laying, maintenance. '
.renewal,'` repair, use, existence or removal of Pipe Line, including the breaking'!of
same or,pany, leakage therefrom, and (b) assume all risk of loss or damage to Pipe Line and
the,,eontentis thereof regardless of how caused and regardless of'.any negligence on the
-part of CariLier, or otherwise.
82631
.. '
ierm 'hereof sha3.1'begin with .... July 24 . il- 81, and continue there-
after til concluded (let) by - exPiratibn.of —....• 'thirty dUye following asryingi
..-
by.'L )., ' Carrierte election without fhrther notice, by expiretion. of
2n4e on 0
'.:. l, ' e -Carrier or vice versa, Of written otice of tntion t end
, n 'ineo term hereof
MoUttis' 1,4. out the Pipe Line Jiiving -been installed or by Licensee tailing (a-l) to cue .,.
az*
cie* t or (a-.2) to show. statutory right to . inst.all- Pine lihe within. —L-.. ' -:
daYart $,1112g Carrierts written request therefor. ' Any notine. f Carrier shall , be 'deemed
servekt wh i n posted conspicuously' on Pipe Line or when deposited postage prepaid in 17.,....
mail 0.:4d' 'Sabi as :aforesaid. Net later than last day of term. h eef Licensee 1 ,shen ,
remeve '. Line and restore ?remises .' Any of Pipe Line not so 2.emoVed shall et'Carrierts 1
i
elec- tbout notice be deemed: abandoned. 'Covenante herein ball inure to or bind each
• *4 tS. legal rep.resenta p
tives, successors and aesiges; Ovided; no right of . "....-
• ' Littene4e a-bn. 1 be transferred Cr assigned,' either volunte.rily, or _involuntarily, except
, -
by - exP-veag. agreement accepte.ble -to Carrier. 'Carrier or Licensee may waive aw, default at,
,..,
any r the. other • without affecting, or impairing any right i ltrieing from, any sub
'
:.";.1.`
1 ASSONNI, ACIIC 4nion COMPANY
.4 caret party h.
'i
v A '9CK 410
iir _..."AfirCas.
vir,,,,...... . OP
• - riarlIdeirisee;:teootd party
50
PRO. 5E WERLINE
X- I N(, FOR CITY OF
R.o,M/ / ROUND ROCK,STA.85$
To TAVLoR
PRO. cf." 50R
PRESSURE - GRAv ITY
3'H IN,
82631
1700 Fr.
PLA N
1 l oo'
2s' r--�
4' MIN,
NOTE BOOK
5EtT ION
No .SCALE
DWN. BY FOX),
25'—
PRO. 12" STEEL
2501.1/,1":,MIN
YLO. sTR. 3s,000 P51
EXHIBIT "A"
OFFICE OF DISTRICT ENGINEER, SPRING, TEXAS
I SCALE NOTED
DATE 7110/V I DWG. NO.
TO SNEED
DISTRICT _
MISSOURI DIVISION RAILROAD SO COMPANY
PALESTINE
SUBD. AUSTIIJ
PRO. 5EwERLI NE X - NG
CITY OF ROUND Roo(
M.P. 147-68 ROUND ROCIyL
MP Rd.
(A) SCOPE
Pipe lines included under these specifications are those installed to carry oil, gas, gasoline or other combustible sub-
stance, under pressure, which from its nature or pressure might cause damage if escaping on or in vicinity of railroad proper-
ty. Gas transmission and distribution lines in city streets, carrying less than 45 -10. pressure, are not to be considered as
coming under these specifications.
1. INSTALLATION:
Pipe lines under railroad tracks and right -of -way shall be encased in a larger pipe or casing and installed as indi-
cated in figure below;
Sign
SeeNote3 .
•
w
SPECIFICATIONS FOR PIPE LINES CONVEYING GAS OR COMBUSTIBLE LIQUID WHERE LOCATED ON RAILROAD PREMISES
tor Right of Way Line
45Ft. Minimum
See Note 2
4 t . Minimum
.4 ; oadbed
t
3Ft.Minimum
Seal —e Vent i at low end
See Notel to be connected to
bottom erasing
EXHIBIT B
To Form 20021
(B) PIPE LINES CROSSING UNDER TRACKS
5 Ft 6m Minimum
t C See • e.ttolo -
Casing
Carrier Pipe
4Ft Minimum
< 4ace
yJ�
3Ft.Minimum
Right of Way Line
< 45 Ft. Minimum
Sin c—r-
See �lote3 a 0 Q
t.
See Note 2
Form 24002 10 -74
I0
40
E
Vent pipe at high See Note l
end to be connected
to top of casing
Note 1. Seal and vent pipe not required if casing ends above ground where drainage is available.
2. Casing to extend beyond limit of railroad right -of -way if necessary to provide proper
length outside of track.
3. Sign indicating location of pipe line at right -of -way line to be installed where required
by the Railroad.
4. For shut -off valves see Section 7.
2. CARRIER PIPE:
Carrier pipe inside of casing under railroad tracks and on right -of -way shall be of good construction (usually the
same as at either side of railroad), of steel, wrought iron, cast iron, pure or alloyed iron; and shall be either seamless or ,
substantially welded pipe with "approved" joints. Pipe at the railroad crossing shall be laid with slack (no tension) in the
line.
3. CASING PIPE:
Casing and joints in sane may be of any conduit construction approved by the Railroad and shall be capable of with-
standing load of railroad roadbed, track and traffic; it shall be so constructed as to prevent leakage of any substance from
the casing throughout its length except at the ends of casing which are left open, or through the vent pipes at the ends of
casing which are sealed to outside of carrier pipe.
Casing shall be installed with even bearing throughout its length and shall slope to one end; it shall be so installed
as to prevent formation of a waterway under the railroad.
Inslde diameter of casing shall be sufficiently large to permit ready withdrawal of carrier pipe without disturbing
the roadbed.
4. SEALS:
Where ends of casing are below ground they shall be suitably sealed to outside of carrier pipe and properly vented
above ground with vent pipes not less than 2 inches in diameter and extending not less than 4 feet above ground surface. Vent
plpe at low end of casing shall be connected with bottom of casing and vent pipe at high end shall be connected with top of
casing. Tops of vent pipes shall be fitted with down turned elbows properly screened.
Where ends of casing are at or above ground surface and above high water level they may be left open, provided drain-
age is afforded in such manner that leakage will be conducted away from railroad tracks o r structures. Where proper drainage
is not provided, ends of casing shall be sealed to outside of carrier pipe and vent pipes shall be installed.
(SEE OTHER SIDE)
5. DEPTH OF CASING:
Where practicable, casing pipe under railroad tracks and across railroad's right -of -way shall be not less than 5 -1/
feet from base of rail to top of casing at its closest point, except that under secondary or industry tracks this dlstanc
may be 4 -1/2 feet. On other portions of rights -of -way where casing is not directly beneath any track, the depth from ground
surface or from bottom of ditches to top of casing shall be not less than 3 feet. Where not practicable to secure the above
depths, special construction approved by Railroad shall be used.
6. LENGTH OF CASING:
The horizontal distances from center line of the nearest outside track to each end of casing shall be at least 45
feet at right angles to the center line of such track. If additional tracks are constructed in the future, diminishing these
distances, the casing shall be correspondingly extended.
7. SHUT -OFF VALVES:
Where required by the Railroad, accessible emergency shut -off valves shall be installed within effective distances
on one or each side of the crossing.
8. LOCATION:
Where practicable, pipe lines shall cross tracks at approximately right angles thereto and shall not be closer than
45 feet to any portion of any railroad bridge, building or other important structure which might be injured by leakage from,
or failure of, the pipe line.
Pipe line, casing and vent pipes shall be at least 4 feet vertically from aerial electric wires and shall be Suit-
ably insulated from underground electric wires on railroad right -of -way.
9. TOPOGRAPHY:
Crossings under railroad tracks of pipe lines carrying combustible substances shall, where practicable, be so in-
stalled that the discharge from the ends of casing or vent pipes shall flow away from the railroad.
10. APPROVAL OF PLANS:
Plans for a proposed crossing shall be submitted to, and meet the approval of, the Railroad before installation is
begun and the execution of the work on railroad right -of -way, Including the supporting of the track, shall be subject to its
inspection and direction. The plans shall include a topographical map of the location of the proposed crossing indicating the
flow of the discharging substance in the event of leakage from, or failure of. the pipe line and a profile of the pipe line
extending in each direction from the proposed crossing to the nearest shut -off valve in the pipe line.
(C) PIPE LINES PARALLELING TRACKS AND ON RIGNT -OP -WAY LANDS
1. LOCATION:
Pipe line shall be located as far as practicable from any track or other important structure, preferably not more
than 5 feet from the right -df -way line, but not closer than 45 feet to the center line of any track or to the nearest point of
any bridge, building or other important structure, "Bridge" as herein used shall not be deemed to include cast iron or con-
crete pipes, or concrete culverts.
2. DEPTH OF PIPE LINE:
Pipe line shall be buried to a depth of at least 3 feet from surface of ground to top of pipe.
3. WATERWAY CROSSINGS:
Pipe lines crossing ravines, waterways, ditches or other surface drains, shall be passed under the channel at a suf-
ficient depth to be protected from scour, manner s
and in such m not to interfere with or obstruct the channel or diminish the
channel capacity. If impracticable to so locate on ountofthe topography of the ground, pipe lines may be elevated suffi-
ciently to avoid drift and be supported on substantial supports, the type and design of which shall be approved by the Rail-
road.
obtain.
4. CASING PIPE REQUIREMENTS:
Casing, conforming to specifications in Sections 3 and 4, Part (H), shall be provided where the following conditions
(a) Where the pressure in the carrier pipe exceeds 400 pounds per square inch.
(b) Where the pipe line is located closer than 45 feet from the center line of any track or from the nearest por-
tion of any bridge, building or other important structure. Such casing shall extend in each direction to a
point at least 45 feet from center line of the track or nearest point of structure to be cleared.
(0) Where the pipe line is deemed by the Railroad to present a hazard to railroad property or operation.
5. CARRIER PIPE:
Carrier pipe and casing shall conform to specifications in Secti 1, 2, 3, 4, 8 and 9, Part (B).
6. SPECIAL CARRIER PIPE:
A special carrier pipe, having a strength at least 50 per cent greater than other portions of the carrier, pipe may
be substituted for the casing required under conditions set forth in Section 4, Part (C), if approved by the Railroad. Pipe
line owner shall submit to the Railroad for approval complete specifications covering such special pipe and its installation.
7. APPROVAL OF PLANS:
Plans for a proposed installation shall be submitted to, and meet the approval of, the Railroad before work is begun
and the execution of the work on railroad right-of-way shall be subject to its inspection and direction. The plans shall In-
clude a topographical map of the location of the proposed pipe line on railroad right -of -way indicating the flow of the dis-
charging substance in the event of leakage from, or failure of, the pipe line and a profile of the pipe line on the railroad
right -of -way and extending in each direction from such right -of -way to the nearest shut -off valve in the pipe line.
APPROVED:
R. E. Davidson
Sr. Vice - President - Operations
E. T. Franzen
Chief Engineer
■
WHEREAS, the City of Round Rock was awarded a Community Development
Block Grant (CDBG) for improvements in the St. William's Subdivision, and
WHEREAS, construction of a 6 -inch sanitary sewer line beneath Missouri
Pacific's right -of -way is necessary for the health and welfare of the citizens
in the St. William's Subdivision, and
WHEREAS, Missouri Pacific Railroad has agreed to allow the construction
of a 6 -inch sewer line in their right -of -way, Now Therefore
BE IT RESOLVED BY THE COUNCIL OF THE CITY OF ROUND ROCK, TEXAS,
That the Mayor is hereby authorized and directed to execute on behalf of
the City a Pipe Line License in order to construct the necessary aforementioned
sewer line, a copy of said license being attached hereto and incorporated
herein for all purposes.
RESOLVED this 28th day of July, 1981.
ATTEST:
4#
ALIA /L_ JtdL/
JO
NE
LAND
, City S-cretary
RESOLUITON NO. 40 / R
LW L. 'e , Mayor
City of Round Rock, Texas
L. H. MILLER
GENERAL MANAGER
B. E. KERLEE
ASSISTANT P. L TUCKER
GENERAL SUPERINTENDENT
3507501
Ms. Joanne Land
City of Round Rock
214 E. Main Street
Round Rock, Texas 78664
Dear Ms. Land:
/drf
Attachment
MISSOURI PACIFIC RAILROAD Go.
24125 ALDINE - WESTFIELD Rn.
SPRING, TEXAS 77373
TEL. AREA CODE 713
November 23, 1981
JSW- Pipe Line: ROUND ROCK, TEXAS
City of Round Rock
1700' east of MP 632
G. R. LILLY
DISTRICT ENGINEER
3507670
J. D. HOPE
MECHANICAL SUPERINTENDENT
O. E. KNOX
ASSISTANT TO GENERAL MANAGER
LAND, LEASE AND CONTRACTS
350-7520
Herewith your original of Pipe Line License dated July 24, 1981,
covering crossing of our right of way at Mile Post 62.68, Williamson County,
Texas, at Round Rock.
Yours very truly,
L. H. MILLER
GENERAL MANAGER
B. E. KERLEE
MANAGER ASSISTANT GENERAL
R. B. SCHOULTZ
GENERA SUPERINTENDENT
350] 501
Mr. Don Grigsby
Hanie & Kallman, Inc.
2115 North Mays
Round Rock, Texas 78664
Dear Sir:
JSO:sdl
Attachment
MISSOURI PACIFIC RAILROAD Go.
24125 ALDINE - WESTFIELD RD.
SPRING, TEXAS 77373
TEL. AREA CODE 713
July 24, 1981
JSO: Pipe Line: ROUND ROCK, TEXAS
City of Round Rock
1700' east of MP 632
Reference is made to your letter dated June 23, 1981, regarding
your firm's requet on behalf of the City of Round Rock, Texas, for per-
mission to construct a 6 -inch sanitary sewer line beneath Missouri Pacific's
right of way at Mile Post 162.68, Engineer's Chainage Station 8487+70,
in Williamson County, Texas at Round Rock.
We are agreeable to permitting this crossing provided it is con-
structed in accordance with our specifications, under our supervision, and
provided our standard form of Pipe Line License is executed. There is a
$500.00 consideration for this crossing.
We have prepared in duplicate and attached hereto originals of our
form Pipe Line License to cover this installation and ask that you cause the
set of originals to be executed. Please have the City Secretary attest and
affix seal in the spaces provided on each of the originals. We shall also need
a Resolution authorizing the Mayor's execution of this license.
The executed Licenses, Resolution and $500.00 consideration should
be returned to the undersigned for processing by the Railroad, which will
return a fully executed License for the City's files.
Please notify our Roadmaster, Mr. V. P. Patton, at Palestine, Texas,
telephone Area Code 214/723 -5238, at least 48 hours prior to the time work
will begin.
Yours very trul
J. Scott O'Neal
District Land & Lease Agent
G. R. LILLY
DISTRICT ENGINEER
3507610
J. D. HOPE
MECHANICAL SUPERINTENDENT
350-7650
O. E. KNOX
MANAGER ASSISTANT TO GENERAL
LE
LAND, CONTRACTS
6 357520
Cise : ca. Mtwo 4 ; and 3.
r • Add ono demote M'EEltdRlpYto.rw
r4 ' modern's orpteted(abmka0.)
�$] Shaw to whom and dab drilvoted............ --it
Show to when;date Adam adder.. —d
' ❑ sztanuavDDEuvray
8hww to w& old data ... «. «..... <
0 B1'AACfEDDBilvERY,
tlewrmldam, dote, sod ad&ao of deltiocti—
PONSEILITOSIWIMM FOR 1
S. 5 c.c:t1w; L.cs.x_
I►
tettriPl p won1011a
f LJ � 1.71
obtain slim "of diaww wr woe
1 hive toff: rod 111; article desdbsd oboes.
tsanttnelto OAdberee OAwboird•d
,
f
►so�ees ....e I
t..a
S. MIME TO EUVIIRBECANR
= T .4
frn
tw>B0Ea1w
UNITED STATES PASTA! SERVICE
QFPaSAm IMMO
30IOE11 INSTRUCTIONS
Plyr roar mime, iddrua, and ZIP Cada k rko apaca baton
• Colvin hRu 1, k and 3 onthe no
• A to rum or MEP S spies prods,
whirr aflk to back N Nib*
• bilk ratd. • tweak Moffat Raooma e
agapant auut"
RETURN
TO
fq A= 4
q P9rrNm aaw
•
O,:+t, 21 ER 00
of Sender)
(Street or P.AHoo[) `
(aty,State, and ZIP Code)
"GOOD LIVING WITH A PROUD HERITAGE'
COUNCIL MEMBERS
MIKE HEILIGENSTEIN
GRAHAM HOWELL
PETE CORREA
JOE BAKER
TRUDV L LEE
BOB BENNETT
City Manager
STEPHAN L SHEETS
City Attorney
RANDY E. DREWETT
Municipal Judge
THE CITY OF ROUND ROCK
214 E. Main St. • AC 512. 255.3612 • Round Rock, Texas 78684
LARRY L TONN
Mayor
MIKE ROBINSON
Mayor Pro-tern
J. Scott O'Neal
District Land & Lease Agent
Missouri Pacific Railroad Co.
24125 Aldine - Westfield Rd.
Spring, Texas 77373
Dear Mr. O'Neal:
Re: Pipe Line: ROUND ROCK, TEXAS
City of Round Rock
1700' east of MP 632
Letter July 24, 1981
Enc.
November 18, 1981
Enclosed please find the necessary Pipe Line License for
the above - captioned project. Also, attached is the City of Round
Rock's check for $500.00 to cover the consideration for the
crossing.
If any further information is needed, please contact this
office at any time.
Sincerely,
CITY OF ROUND ROCK
Qoammx-)6L
Joanne Land
City Secretary
CITY OF ROUND ROCK
COMMUNITY DEVELOPMENT BLOCK GRANT
214 9 MAIN
ROUND ROCK, TEXAS 78864
PAY TO THE
ORDER OF
—CITY Of- 4° ...a.��.y... it ....,.n.m....a,a PULL .iakill A l1AlR. 2GL 00
-1: L L49047461: ""'00uu080 2n■
8&44
✓✓✓✓'"' t9ZL
`/ 1
257
DOLLARS
POSTA
CERTIFIED FEE
P SPECIAL DELIVERY
RESTRICTED DELIVERY
w SHOW TO WHOM AND
�?
DATE D_'JVERED
SNOW TO WHOM, DATE
AND ADDRESS DF
DELIVER`,
SHOW TO WHOM AND DATE
DEL'!VEED WITH RESTRICTED
DE; ,VERY
SHOW TO WHOM, DA lE AND
ADORES'S OF DEJVERY WITH
RESTFICTEN DEI WRY
TOTAL POSTAGE ANDEEES
POSTMARK OR _
P24
PT FOR CERTIFIED MAIL.
NO INSURANCE COVERAGE PROVIDED —
NOT FOR INTERNATIONAL MAIL
(See Reverse)