CM-11-02-044ROUND ROCK, TEXAS
PURPOSE. PASSION. PROSPERITY
Item Caption:
Approval Date:
City Manager Approval Summary Sheet
Consider executing a TCEQ Application to Obtain or Amend a Water or Sewer Certificate
of Convenience and Necessity (CCN).
February 18, 2011
Department: Infrastructure Development and Construction Management
Project Manager: Michael Thane
Item Summary:
The City of Round Rock is submitting this application to the Texas Commission on Environmental Quality (TCEQ) to
amend the City's Water Certificate of Convenience and Necessity (CCN) service area on the south side of town. This
amendment is necessary in order for the City to serve the property that Manville Water Supply Corporation released
from their CCN service area. Once the application is approved by the TCEQ, the City will be able to legally provide
water service to the property.
Strategic Plan Relevance: 27.0 "Ensure there is an adequate, affordable and safe water supply."
Cost:
Source of Funds:
N/A
N/A
REV. 6/10/10
Uri
... .
ma__ .
--riL.iii
TCEQ
APPLICATION TO OBTAIN OR AMEND A WATER OR SEWER
CERTIFICATE OF CONVENIENCE AND NECESSITY (CCN)
Ovi-it-oE-oi-pi
TCEQ-10362 (REV 4/09) Page 1 of 28
GENERAL INFORMATION
* * * THIS APPLICATION IS NOT A RATE CHANGE APPLICATION. THE
APPROPRIATE FORMS NEEDED TO FILE A RATE CHANGE APPLICATION MAY BE
OBTAINED FROM THE TEXAS COMMISSION ON EVNIRONMENTAL QUALIY'S
(TCEQ'S) WEBSISTE OR BY CONTACTING THE UTILITIES AND DISTRICTS SECTION
OF THE TCEQ. 111
osF Pursuant to V.T.C.A., Water Code, Chapter 13, Subchapter G:
❑ CCNs may be obtained by any retail public water and/or sewer utility.
❑ CCNs are required for:
a) Investor Owned Utilities (IOU);
b) Non-profit, member -owned, member -controlled water supply or sewer
service corporations (WSC) incorporated under Water Code, Chapter 67; and
c) Affected counties.
❑ CCNs may be required for political subdivisions, except affected counties, before utility
service can be provided to an area already lawfully being served.
A CCN gives the holder:
❑ the legal right to provide water and/or sewer utility service;
❑ the legal right to be compensated, either directly through a monthly rate or indirectly
through maintenance fees, property owners fees, etc.;
❑ a delineated service area; AND
❑ the obligation to provide service to every customer and qualified applicant who requests
service within that area.
A CCN is not required when service is either submetered pursuant to Water Code, Chapter 13,
Subchapter M, or included in the rental of the property.
EGF IOUs and WSCs with less than 15 potential retail water service connections may register as
Aexempt@ and then are not required to possess a CCN for their service area if they meet the
exemption criteria. This exemption does not apply to sewer providers with less than 15 potential
retail sewer connections. Retail sewer utilities must obtain a CCN to provide retail sewer service
to more than one connection.
This application shall not be changed, altered or amended from its original form only
available from the TCEQ.
PROCESSING YOUR CCN APPLICATION
FLOW CHART
Attached are flowcharts of the review process. Your application will go through an
Administrative Review and, when accepted for filing, a Technical Review. For uncontested
applications, processing time depends on the response time of the applicant. Contested
applications generally take longer because of the need for scheduling a public hearing, and
processing time depends on whether a settlement agreement between the applicant and the
protestor(s) is reached.
TCEQ-10362 (REV 4/09) Page 2 of 28
CCN Administrative (Admin) Review Process -Flowchart
CAdministrative
Review
Process
-Application # assigned
Setup files
Enter in Water Utilities Database (WUD)
10
days
Checklist
Admin complete
No or Incomplete
Response
Received
•
Return
File
Not OK
30 day NOD
Complete
Response
Received
OK
Admin Review for
Completeness
C05/09 )
0-10 days
Admin Review for
Overlap Check/Maps
Application accepted for filing
and Begin Technical Review
(BTR) letter with revised notices
mailed to applicant.
•
Forward Official
File to Staff for
Technical review
* Includes TWC 13.255, 13.254 and 13.246 type applications.
TCEQ-10362 (REV 4/09) Page 3 of 28
CCN Technical (Tech) Review Application Process -Flowchart
1 Begin
Technical
Review (BTR)
Process
No
Tech. Review
Team Leader
•
Team Leader Assigns
to Technical Staff
BTR
Applicant provides/publishes notice
30 days protest period begins
Applicant submits notice affidavits
Staff reviews application for proper
notice, tariff, maps, and criteria for
deficiencies
( 05/09
equeste
information
submitted?
30 day
NOD
Application sent to
State Office of
Administrative
Hearings (SOAH),
legal, and CCO.
Preliminary hearing
scheduled
Requested
information
submitted
Yes
Evidentiary Hearing
t
Agreement reached
at pre -hearing?
14 Day NOD
Letter Sent
Yes
Requested
Information
Received
Staff recommendation,
including maps, tariff,
letter to applicant and
consent form prepared
Recommend by
ALJ
Recommendation
of Administrative
Law Judge (ALJ)
to Remand Case
•
Application
Returned
To CCO for
Posting on EDs
Agenda
Remand Order
from Legal
Consent
Received
Commission
Decision
Approval by the
Executive Director
Map Request to
Cartographer
To CCO for
posting on
ED's Agenda
Motion to Overturn
General Council
* Includes TWC 13.255, 13.254 and 13.246 type applications.
TCEQ-10362 (REV 4/09)
•
Page 4 of 28
NF ADMINISTRATIVE REVIEW OF YOUR CCN APPLICATION
❑ Your application will be reviewed for completeness by the Commission staff within ten (10)
working days after it is received in our offices.
❑ Proposed notice forms are included with the application.
❑ If the application is administratively incomplete, you will be sent a letter that outlines the
application=s deficiencies and describes what is needed to correct the deficiencies. After
receiving that letter, you will have thirty (30) days to make the necessary corrections.
If you fail to make the corrections in full,
(a) the application will be returned,
(b) the application fee will be forfeited, and
(c) if you are already operating a system, you will be referred for enforcement
action which may include administrative penalties of up to $500 per day.
NOTICE
The Commission cannot grant a CCN until proper notice of the application has been given. It is the applicant's
responsibility to ensure that proper notice is given. Notice forms for publication, neighboring cities and
systems, customers, and landowners are included with this application to use as a template in preparing your
proposed notices. These notice forms are also available in Spanish upon request. If the applicant is an operating
IOU currently providing service without a CCN, then proposed notices must be provided for publication, to
neighboring cities and systems, landowners with 25 acres or more, and current customers in the proposed service
area. All three forms must be completed and submitted with the application. However, if the applicant has no
customers in the proposed area at the time of filing and is only proposing to provide service at some future date,
or if the applicant is a WSC or political subdivision, then only the notices for landowners with 25 acres or more,
publication and neighboring cities and systems must be submitted. Do not publish the notice or send copies of
the proposed notices or maps to anyone before submitting this application to the Commission. Your
proposed notices and maps will be reviewed for completeness. When your application is accepted for filing, you
will be directed to provide the appropriate notices for publication, to the neighboring cities and systems and, if
necessary, to current customers.
Ersr TECHNICAL REVIEW OF YOUR CCN APPLICATION
When the application is accepted for filing, you will be notified by mail and will be required:
❑ to publish notice once each week for two (2) consecutive weeks in a newspaper of general
circulation in your local area and county. If the proposed area is in more than one county,
publication in each county is required;
❑ to provide individual notice with a copy of the proposed CCN map to neighboring cities and
systems within:
a) two (2) miles of your proposed service area, if you are an existing retail public utility
amending the existing service area, or
b) five (5) miles if you are obtaining a new CCN to serve a new service area, and
❑ to provide individual mailed notice with a copy of the proposed CCN map to all affected current
customers if you are required to have a CCN but are currently providing service without a CCN.
If the application is technically incomplete, you will be sent a letter that outlines the application=s
deficiencies and describing what you need to do to correct the deficiencies. After receiving that letter,
you will have thirty (30) days to make the necessary corrections. If you fail to make the corrections in
full:
a) the application will be returned,
b) the application fee will be forfeited, and
c) if you are already operating a system, you will be referred for enforcement action
which may include administrative penalties of up to $500 per day.
TCEQ-10362 (REV 4/09) Page 5 of 28
V.T.C.A. Water Code Section 13.246(c) requires the Commission to consider the following factors before it can
issue a CCN:
❑ the adequacy of service currently provided to the requested area;
❑ the need for additional service in the requested area, including whether any landowners;
prospective landowners, tenants, or residents have requested service;
❑ the effect of the granting of a certificate or amendment on the recipient of the certificate or
amendment, on the landowners in the area, and on any retail public utility of the same kind
already serving the proximate area;
❑ the ability of the applicant to provide adequate service, including meeting the standards of the
commission, taking into consideration the current and projected density and land use of the area;
❑ the feasibility of obtaining service from an adjacent retail public utility;
❑ the financial stability of the applicant to pay for the facilities necessary to provide continuous and
adequate service and the financial stability of the applicant including, if applicable, the adequacy
of the applicant=s debt -equity ratio;
❑ environmental integrity;
❑ the probable improvement of service or lowering of cost to consumers in that area resulting from
the granting of the certificate or amendment; AND
❑ the effect on the land to be included in the certificated area.
In addition to these factors,
❑ the Commission must ensure that the applicant possesses the financial, managerial, and technical
capability to provide continuous and adequate service AND
❑ the applicant must also demonstrate that regionalization or consolidation with another retail
public utility is not economically feasible.
If there are no protests, you will be provided a copy of the technical staff recommendation and proposed CCN. If
you have any questions or concerns, you should contact the technical staff person assigned to your application
immediately. If you disagree with the staff recommendation and/or proposed CCN, the application will be
considered contested, and a hearing may be requested.
If the application is contested and a hearing is requested, the application may be referred to the State Office of
Administrative Hearings (SOAH). During the preliminary hearing, the presiding Administrative Law Judge
(ALJ) may give the parties time to negotiate a settlement. Alternative Dispute Resolution (ADR) is available
upon request of all of the parties. If a settlement is reached, the application will be remanded to staff for
administrative processing. If a settlement is not reached, a discovery schedule and a date for an evidentiary
hearing will be set. The ALJ will take testimony from each party and present a report to the Commission to
consider in making a final decision on the application.
The completed application and copies should be sent to:
Texas Commission on Environmental Quality
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
***THIS APPLICATION IS NOT A RATE CHANGE APPLICATION.
THE APPROPRIATE FORMS NEEDED TO FILE A RATE CHANGE
APPLICATION MAY BE OBTAINED BY CONTACTING THE UTILITIES
AND DISTRICTS SECTION, TEXAS COMMISSION ON
ENVIRONMENTAL QUALITY. * * *
TCEQ-10362 (REV 4/09) Page 6 of 28
APPLICATION TO OBTAIN OR AMEND A WATER/SEWER
CERTIFICATE OF CONVENIENCE AND NECESSITY (CCN)
TCECI*CN# *RN# If known (See Instructions)
PURPOSE OF THIS APPLICATION
OBTAIN New Water CCN New Sewer CCN
AMEND x Water CCN # 11047 Sewer CCN #
1. APPLICANT INFORMATION
Utility Name: City of Round Rock
Utility Address 221 East Main Street
(city/state/zip) Round Rock, TX 78664
Utility Phone Number (512) 218-5400 Fax ( )
Contact Person: Please provide information about the person to be contacted regarding this application.
Indicate if this person is the owner, operator, engineer, attorney, accountant manager, or other title related to
the applicant.
Name: Michael Thane, P.E. Title: Director of Infrastructure Management
Address: 2008 Enterprise Dr. Telephone ( ) 512 671-2755
City Round Rock St TX Zip 78664 Fax ( ) 512 218-5563
E-mail: mthane@round-rock.tx.us
County(ies) in which service is proposed Williamson
A. Check the appropriate box and provide information regarding the legal status of the applicant:
Investor owned utility
Individual
Home or Property Owners Association
Partnership
For-profit corporation
Non-profit, member -owned, member -controlled cooperative corporation (Water Code
Chapter 67, Water Supply or Sewer Service Corporation)
X Municipality
District
Other Please Explain:
B. If the applicant is a For -Profit business or corporation: Not Applicable
i. Provide a copy of the corporation=s ACertification of Account Status@ from the Texas
State Comptroller of Public Accounts.
ii. Provide the corporation=s charter number as recorded with the Office of the Texas
Secretary
of State.
iii. Provide a listing of all stockholders and their respective percentages of ownership.
iv. Provide a copy of the company's organizational chart, if available.
v. Provide a list of all directors and disclose the tile of each individual.
vi. Provide a list of all affiliated organizations (if any) and explain the relationship with the
applicant.
TCEQ-10362 (REV 4/09) Page 7 of 28
C. If the applicant is a Water Code Chapter 67 water supply or sewer service corporation: Not
Applicable
i. Provide a copy of the Articles of Incorporation and By -Laws.
ii. Provide the corporation=s charter number as recorded with the Office of the Texas
Secretary of State.
iii. Identify all members including name, address, title, and telephone number.
iv. Provide a copy of the corporation's Certificate of Account Status from the Texas
Comptroller of Public Accounts.
2. LOCATION INFORMATION
A. Are there people already living in the proposed area?
YES X NO
If YES, are any currently receiving utility service?
YES NO X if YES, from Whom?
Demonstrate the Need for Service by providing the following:
B. Have you received any requests for service in the requested service area?
YES X NO if YES, provide the
following:
i. Describe the service area and circumstances driving the need for service in the requested
area. Indicate the name(s) and address(es) of landowner(s), prospective landowner(s),
tenant(s), or resident(s) that have requested service; and/or: Warner Ranch PUD among
other developers are requesting- water service. The requested area to amend is in
Round Rocks' city limits. The City of Round Rock can provide immediate water
service with minimal cost for infrastructure improvements.
ii. Describe the economic need(s) for service in the requested area (i.e. plat approvals, recent
annexation(s) or annexation request(s), building permits, septic tank permits, hospitals,
etc.); and/or: Plat approvals, building permits, PUD service request.
iii. Discuss in detail the environmental need(s) for service in the requested area (i.e. failing
septic tanks in the requested area, fueling wells, etc.); and/or Not Applicable
iv. Provide copies of any written applications or requests for service in the requested area;
and/or
See attached letter from Warner Ranch PUD
v. Provide copies of any reports and/or market studies demonstrating existing or anticipated
growth in the requested area. If no, please justify the need for service in the proposed
area.
Over the past several years the City of Round Rock has had numerous developers in
this area wanting to develop, yet prevented due to lack of utility service.
vi. If none of these items exist or are available, please justify the need for service in the
proposed area in writing. Not applicable.
Note: Failure to demonstrate a need for additional service in the proposed service area may
result in the delay and /or possible denial of the application.
C. Is any portion of the proposed service area inside an incorporated city or district?
YES X NO
If YES, within the corporate limits of: City of Round Rock (applicant)
Provide a copy of any franchise, permit, or consent granted by the city or district. If not available
please explain:
Proposed service areas are inside only the City of Round Rock (applicant) city limits and
/or ETJ — proposed service areas are not within any other incorporated city
TCEQ-10362 (REV 4/09) Page 8 of 28
D. Is any portion of the proposed service area inside another utility=s CCN area?
YES X NO
If YES, has the current CCN holder agreed to decertify the proposed area?
YES NO X
If NO, are you seeking dual or single certification of the area? Explain why decertification of the
area is in the public interest Yes. The City of Round Rock is seeking dual certification of the
area. According to TCEQ the current service provider is shown to be TP Investments. The
CCN number is 12064. The area's North boundary is Louis Henna Blvd. The East boundary
is Warner Ranch Drive. The South boundary is approximately 156 feet from Dry Branch
Creek. The West boundary is Jazz St.
3. MAP REQUIREMENTS:
Attach the following hard copy maps with each copy of the application: See attached maps and
compact disk with digital shapefiles
A. A general location map delineating the proposed service area with enough detail to
accurately locate the proposed area within the county.
B. A map showing only the proposed area by:
metes and bounds survey certified by a licensed state or register professional land surveyor; or
projectable digital data with metadata (proposed areas should be in a single record and clearly
labeled). Also, a data disk labeled with the applicant's name must be provided; or
following verifiable natural and man-made landmarks; or
a copy of recorded plat map with metes and bounds.
C. A written description of the proposed service area. The proposed service area is bound
by Louis Henna Blvd from Jazz St. to approximately 301 feet to the west of A. W. Grimes Blvd. then
runs Southeast to approximately 302 feet South of Louis Henna Blvd., then runs Northeast to AW
Grimes Blvd. The boundary then runs Southeast along Louis Henna Blvd.approximately 305 feet,
then runs Southwest approximately 250 feet. The boundary then runs Southeast approximately 180
eet then turns Northeast and runs a roximatel 295 eet. The bounda then runs Southeast alon
AW Grimes Blvd approximately 110 feet then runs Southwest approximately 530 feet. The boundary
then runs Northwest approximately 1000 feet, then jogs Northwest along Warner Ranch Dr
approximately 150 feet. The boundary then runs West approximately 662 feet, then runs Northwest
along Jazz St. and closes the boundary at Jazz St. and Louis Henna Blvd
There is a second boundary in the same area that starts approximately 160 feet North of the
Northeast end of Thibodeaux Dr. and runs Southeast approximately 166 feet, then runs
Southwest approximately 137 feet. Then boundary then runs Southeast approximately 1,525
eet then runs Norrtheast a roximatel 607 eet. The bounda then runs Southeast
approximately 576 feet, then runs Southwest approximately 405 feet. The boundary then runs
Northwest approximately 527 feet, then runs Southwest approximately 402 feet. The boundary
then runs Southeast approximately 575 feet, it then runs Southwest approximately 1500 feet.
The boundary then runs Northwest approximately 1300 feet, it then runs Southwest
approximately 267 feet. The boundary then runs Northwest approximately 1800 feet, it then
runs Northeast approximately 1700 feet and closes the boundary.
Provide separate and additional maps of the proposed area(s) to show the following:
i. all facilities, illustrating separately facilities for production, transmission, and distribution
TCEQ-10362 (REV 4/09)
Page 9 of 28
of the applicant's service(s); and
ii. any facilities, customers or area currently being served outside the applicant's certificated
area(s).
Note: Failure to provide adequate mapping information may result in the delay or possible denial of
your application. Digital data submitted in a format other than ESRI AreGIS may result in the
delay or inability to review applicant's mapping information.
4. NEW SYSTEM INFORMATION OR UTILITIES REQUESTING A CCN FOR THE FIRST
TIME
A. Please provide the following information:
i. a list of public drinking water supply system(s) or sewer system(s) within a 2 mile radius
of the proposed system; Round Rock and Manville
ii. copies of written requests seeking to obtain service from each of the public drinking
water systems or sewer systems listed in #4.A.i above or documentation that it is not
economically feasible to obtain service from each entity; See letter from Warner Ranch
PUD
iii. copies of written responses from each system or evidence that they did not reply; and
iv. for sewer utilities, documentation showing that you have obtained or applied for a
wastewater discharge permit. Not Applicable
B. Were your requests for service denied?
Not Applicable
i. If yes, please provide documentation of the denial of service and go to 4.C.
ii. If no, please provide a detailed analysis which justifies your reasons for
not accepting service. A separate analysis must be prepared and submitted for each utility
that granted your request for service.
C. Please summarize how the proposed utility system will be constructed and describe each
projected construction phase, if any: The Citv of Round Rock has offsite utilities to serve
the proposed area. Future water service installments
in this area will be constructed b develo i ers.
D. Date of plat approval, if Not Applicable
required:
Approved by:
E. Date Plans & Specifications submitted for Not Applicable Log No.
approval
Attach copy of approval letter if available.
F. Date construction is scheduled to Not Applicable
commence
G. Date service is scheduled to commence Not Applicable
5. EXISTING SYSTEM INFORMATION
A. Please provide the following information for each water and/or sewer system, attach additional sheets if
necessary.
i. Water system's TCEQ Public Water Sstem identification number(s):
6 0 0 0 7
2
4
ii. Sewer system's TCEQ Discharge Permit number(s)
1 1 1 1 1 1 1 1 1 1 1
TCEQ-10362 (REV 4/09)
1 1 1 1 1 1 1 1 1 1
Page 10 of 28
iii Date of last June 27, 2007
inspection
iv Attach a copy of the most recent inspection report letter. See attached inspection
report letter.
v. For each system deficiency listed in the inspection report letter, attach a brief
explanation listing the actions taken or being taken by the utility to correct the listed
deficiencies, including the proposed completion dates.
B. Provide the following information about the utility=s certified operators. See attached utility certified
operators
Name
Classes
License Number
- Attach additional sheet(s) if necessary —
C. Using the current number of customers, is any facility component in systems named in #5A above
operating at 85% or greater of minimum standard capacity?
YES NO X
Attach an explanation listing the actions to be taken to make system improvements including proposed
completion dates (See 291.93(3)(A) of TCEQ Rules).
D. List in the table below, the number of existing and/or proposed metered and non -metered connections (by
size). The proposed number should reflect the information presented in the business plan or financial
documentation and reflect the number of service requests identified in Question 2.b in the application.
Water System
Sewer System
Connection
Existing
Proposed
Connection
Existing
Proposed
5/8" or 3/4" meter
29,351
1200
Residential
N/A
N/A
1" meter or larger
1454
113
Commercial
N/A
N/A
Non -Metered
N/A
N/A
Industrial
N/A
N/A
Other:
N/A
N/A
Other:
N/A
N/A
Total Water
30,805
1,313
Total Sewer
N/A
N/A
E. If this application is for a water CCN only, please explain how sewer service is or will be provided:
The sewer service for this area is provided by: The City of Round Rock and Southwest Water
Company.
TCEQ-10362 (REV 4/09)
Page 11 of 28
F. If this application is for a sewer CCN only, please explain how water service is or will be provided:
Not Applicable.
G Effect of Granting a Certificate Amendment.
Explain in detail the effect of granting of a certificate or an amendment, including, but not limited to
regionalization, compliance and economic effects on the following:
i the applicant,
ii any retail public utility of the same kind already serving the proximate area; and
iii any landowner(s) in the requested area.
The effect of granting this request on the applicant (Round Rock) is that the change in
water service CCN will ensure a CCN designation for this area and will spur growth and
development in the area.
H Do you currently purchase or plan to purchase water or sewer treatment capacity from another source?
i No X (skip the rest of this question and go to #6)
ii Water Yes
Purchased on a X regular seasonal Emergency basis?
Source
% of Total Treatment
Brazos River Authority
Lake Georgetown and Lake Stillhouse
Hollow
92
Ground Water
8%
iii Sewer treatment capacity
iv Yes
Purchased on a
regular
seasonal
Emergency basis?
Source
of Total Treatment
vi Provide a signed and dated copy of the most current water or sewer treatment capacity
purchase agreement or contract.
TCEQ-10362 (REV 4/09)
Page 12 of 28
Ability to Provide Adequate Service.
Describe the ability of the applicant to provide adequate service, including meeting the standards
of the commission, taking both of the following items into consideration:
i. the current and projected density, and
ii. the land use of the requested area.
The City of Round Rock has the water infrastructure capacity available to serve the
proposed area.
J Effect on the Land.
Explain the effect on the land to be included in the certificated area. Will provide positive effect on by
enabling The City of Round Rock to commit to providing water service to this area, which will enable
growth and development.
6. FINANCIAL INFORMATION
A. For new systems and for applicants with existing CCNs who are constructing a new stand alone system:
Not Applicable
i. the applicant must provide an analysis of all necessary costs for constructing, operating,
and maintaining the system, and the source of that capital (such as a financial statement
for the developing entity) for which the CCN is requested for at least the first five years.
In addition, if service has been offered by an existing water service provider as stated in
#4.A., but the applicant has determined that the cost of service as finally offered renders
the project not economically feasible, the applicant must provide a comparison analysis
of all necessary costs for acquiring and continuing to receive service from the existing
system for the same period.
ii. Attach projected profit and loss statements, cash flow worksheets, and balance sheets
(projected five year financial plan worksheet is attached) for each of the first five years of
operation. Income from rates should correlate to the projected growth in connections,
shown on the projected profit and loss statement.
iii. Attach a proposed rate schedule or tariff. Describe the procedure for determining the
rates and fees and indicate the date of last change, if applicable. Attach copies of any
cost of service studies or rate analysis worksheets.
B. For existing systems:
i. Attach a profit and loss statement and current balance sheet for existing businesses (end
of last fiscal year is acceptable). Describe sources and terms for borrowed capital such as
loans, bonds, or notes (profit and loss and balance sheet worksheets are attached, if
needed). See attached Comprehensive Annual Finacial Report
ii. Attach a proposed rate schedule or tariff.
*NOTE: An existing system may be required to provide the information in 6.A.i. above during
the technical review phase if necessary for staff to completely evaluate the application.
C. Identify any funds you are required to accumulate and restrict by lenders or capital providers.
Not Applicable
D. In lieu of the information in #6.A. thru #6.C., you may provide information concerning loan approvals
within the last three (3) years from lending institutions or agencies including the most recent financial
audit of the applicant. Not Applicable
Note: Failure to provide adequate financial information may result in the delay or possible denial of your
application.
7. NOTICE REQUIREMENTS
A. All proposed notice forms must be completed and submitted with the application. However, do not mail
or publish them until you receive written approval from the Commission to do so.
TCEQ-10362 (REV 4/09) Page 13 of 28
B. The Commission cannot grant a CCN until proper notice of the application has been given. Commission
rules do not allow a waiver of these notice requirements for CCN applicants.
C. It is the applicant=s responsibility to ensure that proper notice is given to all entities that are
required to receive notice.
D. Recommended notice forms for publication, neighboring cities and systems, landowners with 25 acres or
more, and customers are included with this application to use in preparing your proposed notices. (These
notice forms are also available in Spanish upon request.)
E. After reviewing and, if necessary, modifying the proposed notice, the Commission will send the notice to
the applicant after the application is accepted for filing along with instructions for publication and/or
mailing. Please review the notice carefully and note any additional neighboring utilities which may be
included in the acceptance letter.
F. Notice For Publication:
The applicant shall publish the notice in a newspaper having general circulation in the county or counties
where a CCN is being requested, once each week for two consecutive weeks beginning with the week
after the notice is received from the Commission. Proof of publication in the form of a publisher=s
affidavit shall be submitted to the Commission within 30 days of the last publication date. The affidavit
shall state with specificity each county in which the newspaper is of general circulation.
G. Notice To Neighboring Utilities:
i. List all neighboring retail public utilities and cities providing the same utility service
within the following vicinities of the applicant's proposed certificate area.
ii. For applications for the issuance of a NEW CCN, the applicant must mail the notice with
a copy of the proposed CCN map to all cities and neighboring retail public utilities
providing the same utility service within five (5) miles of the requested service area.
iii. For applications for the AMENDMENT of a CCN, the applicant must mail the notice
with a copy of the proposed CCN map to all cities and neighboring retail public utilities
providing the same utility service within two (2) miles of the requested service area.
H. Notice to Customers
Investor Owned Utilities (IOUs) that are currently providing service without a CCN must provide
individual mailed notice to all current customers. The notice must contain the current rates, the date those
rates were instituted and any other information required in the application. The notice must also list all zip
codes affected by the application. Not Applicable
I. The Commission may require the applicant to deliver notice to other affected persons or agencies.
Do not publish or send copies of the proposed notices to anyone at the
time you submit the application to the Commission. Wait until you
receive written authorization to do so. This will occur after the
Commission has reviewed the notices for completeness, and your
application has been accepted for filing. Once the application is
accepted for filing, you will receive written authorization to provide
notice. Please check the notices for accuracy before providing them to
the public. It is the applicant's burden to ensure that correct and
accurate notice is provided.
TCEQ-10362 (REV 4/09)
Page 14 of 28
OATH
STATE OF Texas
COUNTY OF Williamson
I, Steve Norwood ,being duly sworn, file this application as
(indicate relationship to Applicant, that is, owner, member
of partnership, title as officer of corporation, or other authorized representative of Applicant); that, in such
capacity, I am qualified and authorized to file and verify such application, am personally familiar with the maps
and financial information filed with this application, and have complied with all the requirements contained in
this application; and, that all such statements made and matters set forth therein are true and correct. I further
state that the application is made in good faith and that this application does not duplicate any filing presently
before the Texas Commission on Environmental Quality.
I further represent that the application form has not been changed, altered or amended from its original form
available only from the Commission.
I further represent that the Applicant will provide continuous and adequate service to all customers and
qualified applicants for service within its certificated service area.
AFFIANT
(Utility's Authorized Representative)
If the Affiant to this form is any person other than the sole owner, partner, officer of the Applicant, or its attorney,
a properly verified Power of Attorney must be enclosed.
SUBSCRIBED AND SWORN TO BEFORE ME, a Notary Public in and for the State of Texas, this
day itt. of ';i4, .44,A , 20 U .
SEAL
TCEQ-10362 (REV 4/09)
ghligLm
NOTARY PiJBLIC IN AND FOR THE
STATE OF TEXAS
Qozh L. Wisftre
PRINT OR TYPE NAME OF NOTARY
MY COMMISSION EXPIRES atIA' �' 04)12 -
Page 15 of 28
Notice for Publication
NOTICE OF APPLICATION FOR CERTIFICATE OF CONVENIENCE
AND NECESSITY (CCN) TO PROVIDE WATER/SEWER UTILITY
SERVICE IN COUNTY(IES), TEXAS
Name of Applicant has filed an application
for a CCN to obtain or amend CCN No. and to decertify a portion(s) of
with the Texas Commission on Environmental Quality to provide
(Name of Decertificated Utility)
(specify 1) water or 2) sewer or 3) water & sewer) utility service in
County(ies).
The proposed utility service area is located approximately miles [direction] of
downtown ,[City or Town] Texas, and is generally bounded on the north by
;on the east by
;on the south by ;and on the west by
See enclosed map of the proposed service area.
The total area being requested includes approximately acres and current customers.
The proposed amendment affects customers and/or areas located in the following zip code(s):
(List All Affected Zip Codes)
A copy of the proposed service area map is available at (Utility Address and Phone Number):
A request for a public hearing must be in writing. You must state (1) your name, mailing address, and
daytime telephone number; (2) the applicant's name, application number or another recognizable
reference to this application; (3) the statement, I/we request a public hearing"; (4) a brief description of
how you or the persons you represent, would be adversely affected by the granting of the application for a
CCN; and (5) your proposed adjustment to the application or CCN which would satisfy your concerns
and cause you to withdraw your request for a hearing.
Persons who wish to intervene or comment should write the:
Texas Commission on Environmental Quality
Water Supply Division
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
within thirty (30) days from the date of this publication or notice. A public hearing will be held only if a
legally sufficient hearing request is received or if the Commission on its own motion requests a hearing.
Only those individuals who submit a written hearing request or a written request to be notified if a hearing
is set will receive notice if a hearing is scheduled.
TCEQ-10362 (REV 4/09)
Page 16 of 28
If a public hearing is requested, the Executive Director will not issue the CCN and will forward
the application to the State Office of Administrative Hearings (SOAH) for a hearing. If no
settlement is reached and an evidentiary hearing is held, the SOAH will submit a
recommendation to the Commission for final decision. If an evidentiary hearing is held, it will
be a legal proceeding similar to a civil trial in state district court.
If you are a landowner with a tract of land at least 25 acres or more, that is partially or wholly
located within the proposed area, you may request to be excluded from the proposed area (or
Aopt out@) by providing written notice to the Commission within (30) days from the date that
notice was provided by the applicant. All requests to opt out of the requested service area must
include a scaled, general location map and a metes and bounds description of the tract of land.
Persons who meet the requirements to opt out, and wish to request this option should file the
required documents with the:
Texas Commission on Environmental Quality
Water Supply Division
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
A copy of the request to opt out of the proposed area must also be sent to the applicant. Staff
may request additional information regarding your request.
TCEQ-10362 (REV 4/09)
Si desea informacion en Espanol, puede llamar al 1-512-239-0200.
Page 17 of 28
To:
Notice to Neighboring Systems, Landowners and Cities
NOTICE OF APPLICATION FOR CERTIFICATE OF CONVENIENCE
AND NECESSITY (CCN) TO PROVIDE WATER/SEWER UTILITY
SERVICE IN COUNTY(IES), TEXAS
(Neighboring System, Landowner or City)
(Address)
City
State Zip
Date Notice Mailed , 20
Name of Applicant has filed an application
for a CCN /to amend CCN No. and to decertify a portion(s) of
with the Texas Commission on Environmental Quality to provide
(Name of Decertificated Utility)
(specify 1) water or 2) sewer or 3) water & sewer) utility service in
County(ies).
The proposed utility service area is located approximately miles [direction] of
downtown ,[City or Town] Texas, and is generally bounded on the north by
;on the east by
;on the south by ;and on the west by
See enclosed map of the proposed service area.
The total area being requested includes approximately acres and current customers.
The proposed amendment affects customers and/or areas located in the following zip code(s):
(List All Affected Zip Codes)
A request for a public hearing must be in writing. You must state (1) your name, mailing address, and
daytime telephone number; (2) the applicant's name, application number or another recognizable
reference to this application; (3) the statement, I/we request a public hearing"; (4) a brief description of
how you or the persons you represent, would be adversely affected by the granting of the application for
a CCN; and (5) your proposed adjustment to the application or CCN which would satisfy your concerns
and cause you to withdraw your request for a hearing.
Persons who wish to intervene or comment should write the:
Texas Commission on Environmental Quality
Water Supply Division
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
within thirty (30) days from the date of this publication or notice. A public hearing will be held
only if a legally sufficient hearing request is received or if the Commission on its own motion
requests a hearing. Only those individuals who submit a written hearing request or a written
request to be notified if a hearing is set will receive notice if a hearing is scheduled.
TCEQ-10362 (REV 4/09)
Page 18 of 28
If a public hearing is requested, the Executive Director will not issue the CCN and will forward
the application to the State Office of Administrative Hearings (SOAH) for a hearing. If no
settlement is reached and an evidentiary hearing is held, the SOAH will submit a
recommendation to the Commission for final decision. If an evidentiary hearing is held, it will
be a legal proceeding similar to a civil trial in state district court.
If you are a landowner with a tract of land at least 25 acres or more, that is partially or wholly
located within the proposed area, you may request to be excluded from the proposed area (or
Aopt out@) by providing written notice to the Commission within (30) days from the date that
notice was provided by the applicant. All requests to opt out of the requested service area must
include a scaled, general location map and a metes and bounds description of the tract of land.
Persons who meet the requirements to opt out, and wish to request this option should file the
required documents with the:
Texas Commission on Environmental Quality
Water Supply Division
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
A copy of the request to opt out of the proposed area must also be sent to the applicant. Staff
may request additional information regarding your request.
TCEQ-10362 (REV 4/09)
Si desea informacion en Espanol, puede llamar al 1-512-239-0200.
Page 19 of 28
Notice to Customers of IOUs in Proposed Area
NOTICE OF APPLICATION FOR CERTIFICATE OF CONVENIENCE AND NECESSITY (CCN)
TO PROVIDE WATER/SEWER UTILITY SERVICE IN COUNTY
Dear Customer:
Date Notice
Mailed
, 20
Name of Applicant has filed an application
for a CCN to amend CCN No. and to decertify a portion(s) of
with the Texas Commission on Environmental Quality to provide
(Name of Decertificated Utility)
(specify 1) water or 2) sewer or 3) water & sewer) utility service in
County(ies).
The proposed utility service area is located approximately miles
downtown , [City or Town] Texas.
[direction] of
A copy of the proposed service area map is available at the Utility Address and Phone Number:
The proposed amendment affects customers and/or areas located in the following zip code(s):
(List All Affected Zip Codes)
The current utility rates which were first effective on
• Monthly Flat Rate of per connection Miscellaneous Fees
-OR-
• Monthly Base Rate
including
per connection for:
Other
5/8" meter
1" meter
1 1/2" meter
2" meter
gallons
Gallonage charge of $ Per 1,000
Gallons above minimum (same for all meter sizes)
Regulatory Assessment
Tap Fee (Average Actual
ost)
Reconnection fee:
- Non Payment ($25.00
Zax)
- Transfer
- Customer's request
Late fee
Returned Check charge
Customer Deposit ($50.00
max)
Meter test fee (Actual Cost not
Exceed $25.00)
Other Fees
, 20
1%
$5.00 or 10%
Your utility service rates and fees cannot be changed by this application. If you are
currently paying rates, those rates must remain in effect unchanged. Rates may only be
increased if the utility files and gives notice of a separate rate change application.
TCEQ-10362 (REV 4/09)
Page 20 of 28
A request for a public hearing must be in writing. You must state (1) your name, mailing address, and
daytime telephone number; (2) the applicant's name, application number or another recognizable
reference to this application; (3) the statement, I/we request a public hearing"; (4) a brief description of
how you or the persons you represent, would be adversely affected by the granting of the application for
a CCN; and (5) your proposed adjustment to the application or CCN which would satisfy your concerns
and cause you to withdraw your request for a hearing.
Persons who wish to intervene or comment should write the:
Texas Commission on Environmental Quality
Water Supply Division
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
within thirty (30) days from the date of this publication or notice. A public hearing will be held only if a
legally sufficient hearing request is received or if the Commission on its own motion requests a hearing.
Only those individuals who submit a written hearing request or a written request to be notified if a
hearing is set will receive notice if a hearing is scheduled.
If a public hearing is requested, the Executive Director will not issue the CCN and will forward the
application to the State Office of Administrative Hearings (SOAH) for a hearing. If no settlement is
reached and an evidentiary hearing is held, the SOAH will submit a recommendation to the Commission
for final decision. If an evidentiary hearing is held, it will be a legal proceeding similar to a civil trial in
state district court.
IF A HEARING IS HELD, it is important that you or your representative attend to present your
concerns. Your request serves only to cause a hearing to be held and is not used during the hearing.
If you are a landowner with a tract of land at least 25 acres or more, and is partially or wholly located
within the proposed area, you may request to be excluded from the proposed area (or Aopt out@) by
providing written notice to the Commission within (30) days from the date that notice was provided by
the applicant. All requests to opt out of the requested service area must include a scaled, general
location map and a metes and bounds description of the tract of land.
Persons who meet the requirements to opt out, and wish to request this option should file the required
documents with the:
Texas Commission on Environmental Quality
Water Supply Division
Utilities and Districts Section, MC -153
P. O. Box 13087
Austin, TX 78711-3087
A copy of the request to opt out of the proposed area must also be sent to the applicant. Staff may
request additional information regarding your request.
TCEQ-10362 (REV 4/09)
Si desea informacion en Espanol, puede llamar al 1-512-239-0200
Page 21 of 28
HISTORICAL BALANCE SHEETS
CURRENT ASSETS
Cash
CURRENT A-1 YEAR A-2 YEAR A-3 YEAR A-4 YEAR A-5 YEAR
YEAR (A)
Accounts Receivable
Inventories
Income Tax Receivable
Other
FIXED ASSETS
Land
Total
Collection/Distribution System
Buildings
Equipment
Other
Less: Accum. Depreciation or Reserves
Total
TOTAL ASSETS
CURRENT LIABILITIES
Accounts Payable
Notes Payable, Current
Accrued Expenses
Other
LONGTERM LIABILITIES
Notes Payable, Long-term
Total
Other
TOTAL LIABILITIES
OWNER'S EQUITY
Paid in Capital
Retained Equity
Other
Current Period Profit or Loss
TOTAL OWNER'S EQUITY
TOTAL LIABILITIES AND EQUITY
WORKING CAPITAL
CURRENT RATIO
DEBT TO EQUITY RATIO
EQUITY TO TOTAL ASSETS
TCEQ-10362 (REV 4/09)
Page 22 of 28
HISTORICAL INCOME STATEMENT
METER NUMBER
Existing Number of Taps
CURRENT
YEAR (A)
A-1 YEAR
A-2 YEAR
A-3 YEAR
A-4 YEAR
A-5 YEAR
New Taps per Year
Total Meters at Year End
METER REVENUE
Fees Per Meter
Cost Per Meter
Operating Revenue Per Meter
GROSS WATER REVENUE
Fees
Other
Gross Income
OPERATING EXPENSES
General & Administrative
Interest
Other
NET INCOME
TCEQ-10362 (REV 4/09)
Page 23 of 28
HISTORICAL
GENERA1JADMINISTRATNE
EXPENSES
Salaries
CURRENT
YEAR (A)
A-1 YEAR
A-2 YEAR
A-3 YEAR
A-4 YEAR
Office Expense
Computer Expense
Auto Expense
Insurance Expense
Telephone Expense
Utilities Expense
Depreciation Expense
Property Taxes
Professional Fees
Other
Total
% Increase Per Year
OPERATIONAL EXPENSES
Salaries
Auto Expense
Utilities Expense
Depreciation Expense
Repair & Maintenance
Supplies
Other
Total
Increase Per Year
ASSUMPTIONS
Interest Rate/Terms
Utility Cost/gal.
Depreciation Schedule
Other
TCEQ-10362 (REV 4/09)
Page 24 of 28
A-5 YEAR
PROJECTED BALANCE SHEE
CURRENT ASSETS
Cash
START UP
YEAR 1
YEAR 2
YEAR 3
YEAR 4
YEAR 5
Accounts Receivable
Inventories
Income Tax Receivable
Other
Total
FIXED ASSETS
Land
Collection/Distribution System
Buildings
Equipment
Other
Less: Accum. Depreciation or Reserves
Total.
TOTAL ASSETS
CURRENT LIABILITIES
Accounts Payable
Notes Payable, Current
Accrued Expenses
Other
Total
LONGTERM LIABILITIES
Notes Payable, Long-term
Other
TOTAL LIABILITIES
OWNER'S EQUITY
Paid in Capital
Retained Equity
Other
Current Period Profit or Loss
TOTAL OWNER'S EQUITY
TOTAL LIABILITIES AND EQUITY
WORKING CAPITAL
CURRENT RATIO
DEBT TO EQUITY RATIO
EQUITY TO TOTAL ASSETS
TCEQ-10362 (REV 4/09)
Page 25 of 28
PROJECTED INCOME ST
METER NUMBER
YEAR 1
YEAR 2
YEAR 3
YEAR 4
YEAR 5
TOTALS
Existing Number of Taps
New Taps per Year
Total Meters at Year End
METER REVENUE
Fees Per Meter
Cost Per Meter
Operating Revenue Per Meter
GROSS WATER REVENUE
Fees
Other
Gross Income
OPERATING EXPENSES
General & Administrative
Interest
Other
NET INCOME
TCEQ-10362 (REV 4/09) Page 26 of 28
PROJECTED EXPENSES STATEMENT
GENERAL/ADMINISTRATIVE EXPENSES
YEAR 1
YEAR 2
YEAR 3
YEAR 4
YEAR 5
TOTALS
Salaries
Office Expense
Computer Expense
Auto Expense
Insurance Expense
Telephone Expense
Utilities Expense
Depreciation Expense
Property Taxes
Professional Fees
Other
Total
% Increase Per Year
OPERATIONAL EXPENSES
Salaries
Auto Expense
Utilities Expense
Depreciation Expense
Repair & Maintenance
Supplies
Other
Total
Increase Per Year
ASSUMPTIONS
Interest Rate/Terms
Utility Cost/gal.
Depreciation Schedule
Other
TCEQ-10362 (REV 4/09)
Page 27 of 28
PROJECTED SOURCES AND USES OF CASH STATEMENTS
SOURCES OF CASH
Net Income
YEAR 1
YEAR 2
YEAR 3
YEAR 4
YEAR 5
TOTALS
Depreciation (if Funded)
Loan Proceeds
Other
_--■
Total Sources
USES OF CASH
Net Loss
Principle Portion of Pmts.
Fixed Asset Purchase
Reserve
-_-_
■_
Other
TOTAL USES
NET CASH FLOW
DEBT SERVICE COVERAGE
Cash Available for Debt
Service (CADS)
Net Income (Loss)
■_■
■_--
Depreciation , or Reserve Interest
■_
TOTAL
REQUIRED DEBT SERVICE (RDS)
Principle Plus Interest
DEBT SERVICE COVERAGE RATIO
CADS Divided by RDS
■_
,
TCEQ-10362 (REV 4/09)
Page 28 of 28