CM-11-04-077ROUND ROCK, TEXAS PURPOSE. PASSION. PROSPERITY Item Caption: City Manager Approval Summary Sheet Consider executing Quantity Adjustment/Change Order No. 5 with Flintco, Inc. for the Intermodal Transit and Parking Facility project. Approval Date: April 22, 2011 Department: Infrastructure Development & Construction Management Project Manager: Larry Madsen Item Summary: The Intermodal Transit and Parking Facility construction was substantially complete February 2011. By approval of this Change Order, the Intermodal Transit and Parking Facility project can be formally closed out with no other financial transactions pending. The purpose of this Change Order is for the following: • Additional work not originally in the scope of services; • Additional cable rails specified for second floor parking; • Canopy modifications due to steel rebar interface and • Heater to elevator machine room. Strategic Plan Relevance: Mobility and Connectivity Strategic Initiative 2060 Vision - Residents and visitors will have alternative choices for transportation including public transportation options, pedestrian/biking options and personal vehicle. 21.0 — Identify and plan for future connectivity and mobility needs and options. Cost: $13,263.00 Source of Funds: 2002 General Obligation Bond and ARRA Funds DM/ L /1 /-% rs rev. 09/10 Contract Quantity Adjustment/Change Order Department: Infrastructure Development & Construction Managen Project Intermodal Transit and Parking Facility Name: City Project ID Number: PTO2ITPF Justification Date: Change Order/Quantity Adjustment No. Page 1 of 3 4/5/2011 5 Consider executing Quantity Adjustment/Change Order No. 5 with Flintco, Inc. for the Intermodal Transit and Parking Facility project. SUMMARY Original Contract Price: Previous Quantity Adjustment(s): This Quantity Adjustment: Total Quantity Adjustment(s): Total Contract Price with Quantity Adjustment(s): Previous Change Order(s): This Change Order: Total Change Order(s) To Date: Original Contract Price Plus Change Order(s) Plus Quantity Adjustment(s): Original Contract Time: Contract Time Prior to this Change Order: Contract Time with All Approved Change Orders: Prepared by: Contractor Approval: City Staff Approval: Signat e Sidnatu Amount $2,530,000.00 $0.00 $0.00 $0.00 $2,530,000.00 0/0 Change $41,802.00 1.65% $13,263.00 0.52% $55,065.00 2.18% $2,585,065.00 *4/8/2011 *4/8/2011 *4/8/2011 Signatures and Approvals Art Arredondo, Barnes Gromatzky Kosarek Architects � ✓ 2 Printed Name, Title and Company Date Daniel Oates, Project Manager Flintco,Inc. ItttmL7,011 Printed Name, Title and Company Date Larry Madsen, Construction Manager, CORR Printed Name and Title Date City Official Approval: 341Alt. goPwond, 'L Q.0 4-22-11 Printed Name and Title �) Date Signature Uw\-lt-oh-o,rt rev. 09/10 Contract Quantity Adjustment/Change Order Change Order Data Page 2 of 3 Bid Item# Item Description and Change Unit Qty. Unit Price Amount Contract Time Adjustment (Days) 1 Additional cable rails specified for second floor parking each 1 $5,590.00 $5,590.00 0 2 Canopy modifications due to steel rebar interface each 1 $4,235.00 $4,235.00 0 3 Add heater to elevator machine room each 1 $4,715.00 $4,715.00 0 4 Credit Balance of contract contingency each 1 ($1,277.00) ($1,277.00) 0 0 $0.00 $0.00 0 0 $0.00 $0.00 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 0 $0.00 $0.00 TOTALS: $13,263.00 0 8100 Cross Park t)r. Austin. TX 78754-7224 Constructive Solutions • REQUEST FOR [NFORtMMATION No. 90052 ('hone: 512.891.7124 Fax: 512.891.7229 TITLE: 1 1 /S4.1 Clari (/cation PROJECT: Round Rock Interniodal TransitIPark TO: Attn: Art Arredondo.AIA Barnes Gromatzky Kosarek A 1508 West 5th Street Suite 200 Austin, TX 78703 Phone: 512-476-7133 Fax: 512-478-2624 QUESTION: Reference detail 11/S4.1. DATE: 12/22;2010 JOB: 4399 STARTED: COMPLETED: REQUIRED: 12/29/2010 Please provide the cable size and spacing for the Cialy. C3x6 pieces In this detail. The top cable must be placed 3'-6" minimum to centerline of cable and the cables below spaced at 3" maximum each with the bottom cable no more than 3" from the concrete wall to center of the cable. The size of the cables are to be similar to the stair railings as these are for pedestrian protection vs. the vehicular concrete barrier protection below. 12/22/2010 Requested By:Plintco Inc. Signed: Daniel Oates Date: Page 7 of 1 !?[[, industries Fabricators of Commercial and Industrial Steel City of 1lnuston Certified 11367 9119 Weedy Ln. Houston, TX 77093 (713)691-5200 Main Fax (713) G91-3355 Saks I,ax (713) 691-4646 CHANGE ORDER REQUEST "h DATE OF CHANGE ORDER January 31, 2011 MYRWX JOB NO. 0954 MYREX CHANGE NO. 08 CUSTOMER CHANGE ORDER OR RFI NO. Myrex drgs 5t3 -X & 500-X PROJECT City of Round Rock Parking Garage CONTRACTOR NAME FLINTCO, INC. PROJECT MANAGER Daniel Oates JOB SITE PFIONE JOB SITE FAX PLEASE. PROCESS A CHANGE ORDER TO OUR PURCHASE ORDER FOR TUE EXTRA WORK DESCRISF_D BELOW.' Additional galvanized guard rail with hard ware connections @ SW stair per myrex dig no 513-X dated 01!24/2011.Additir stainless steel cable rail with hard ware connections per myrex drag no 500-X dated 1/21/2011. All materia! will be painted with one coat of Myrex standard shop primer with SSPC-SP2 cleaning o.n.o. Materials iFlat bars Material Amount 30801 -� Fabrication %tinho rrs 1 5.00 Hourly Rate 1 45.00 Fabrication Labor 1 .2e15:013". ,. ti Detailing Manhours 3.00 Hourly Rate 45.00 Detailing Time 11,35,ga ,-.(7) Freight 1- 100.00 ITEM DESCRIPTIONS AND AMOUNTS: Galvanizing, Miscellaneous, Buyouts, etc. Stainless steel cable with connections 2,000.00 Bard ware fittings @ guard rail 1 632.00 1 1 See Page 2 for Grand Total Chu:go U.,!n Pr:n•.-f 7II0611 Paso 4 at NOTES The status of this Change Order Is Subtotal from Page 1 J I 10.00% Overhead 1 312.20 Z-131?0 5.00% Profit I 156.10 I 'yo, �O Erection l Erection OverheadlProfit J 0.00 3,4 2Too 2.1 $'2` CHANGE TOTALS Change Amount Tax Amount ) 0.00 GRAND TOTAL ���� Unapproved Approved = Myrex has received formal Change Order. Unapproved = Myrox has been authorized to proceed, with formal Change Order to follow. Quoted only = Myrex has not been authorized to proceed. Please initial here to verify Change Order status. FLINTCO, INC. Authorized Signature NOTES: EXTRA WORK WILL NOT BE PERFORMED UNTIL A SIGNED COPY IS RETURNED TO MYREX INDUSTRIES. THE CHANGES QUOTED HEREIN WILL tMPP.CT TIME MYREX PRODUCTION SCHEDULE BY A MINIMUM OF 2 DAYS. Cnanyo 4 995401 Date Prn:M 7J1/2011 Pate 7 nl : A. G. Welding 8125 McGee Lane Houston, TX 77071 713-988-4200 Fax:713-988-4267 Bil To Flinlco LLC Daniel Oates Project Manager Rep GF Invoice Date Invoice* 2/I/2011 8995 ADDITIONAL INFORMATION City of Round Rock Garage 300 Baghdad Round Rock, TX PHONE FAX 479-445-4651 OTHER INFORMATION Description Amount Fabricate and instal approximately 82 linear fed x 12 rows stainless steel railing. Cable is 1/8" diameter. Railing (including posts with holes) is installed. Cable and fasteners supplied by customer. A.G. Wilding to cut cable to appropriate length. install cable and tighten cable. Note: Pricing assumes post holes are in the correct location. and enough cable and fasteners have been ordered and arc onsite. Additional costs will be incurred if holes have to be re -drilled and/or sealed, or if standby time is required waiting for additional materials to be ordered/delivered. 1.940.00 Total Amount Due S1,940.00 Proposed Change Order #21 City of Round Rock Intermodal Transit and Parking Facility City of Round Rock, TX Owner: The City of Round Rock Description: RFI 57 - Modifications to canopy connections at columns due to rebar locating the rebar to insure the new design is part of GPRS's cost. A: Material & Equipment: B: Labor S Sales Tax ( 0.00%) $ Constructive Solutions interference. The cost of Subtotal A S S Labor Burden ( 44.00 %) S C: Subcontractors - See attached quotations Sundance Modify Plates Sundance Dummy Bolts Ground Penetrating Radar Systems D. General Contractor Mark-Up ( 10%) F. Contract Time Extension 0 Calendar Days FItn By: Daniel O es - Project Manager Date Signed Subtotal B S Subtotal C Subtotal A - C Subtotal D Asbestos Auowance Change Order S S S 1,850.00 500.00 1,500.00 3,850.00 3,850.00 385.00 TOTAL: $ The City of Round Rock By: 385.00 4,235 Larry Madsen - Public Works Rep Date Signed Barnes, Gromatzky, Kosarek Architects By: Arturo Arredondo Date Signed I'ark 1)r rx (` N6ii\R'I'CO Constructive Solutions REQUEST FOR INFORMATION No. 00057 I'h�inc: ;11 891 7224 Fat: 51'.S91.7'29 TITLE: Canopy \loiliticatlotls PRO.IECT: Roun&i Rel: Intermodal I r;tnsit O: Attn: Art Arredondu..\ L\ Barnes f ironrttif.\ Ko,;uel \ I;o:: \\ est 5th tits;:et Suite _'()l) Austin. TX 7 71).i Phone: 512-176-71i; QUESTION: Reference attached clr;tt: tnu. !:;R: 5I DA"h[.:: 1 26:201 1 .1O13: -1309) REQUIRE[): 2 2;21)1 1 1. I'icasc confirm the attached tlr;t:cin_ is ;in acceptable modification to the canupsupport plates. The plates «ill he modified per the;tttachcd dr;m-iT2 to ntintnuie rchar interference. 2. )-here will he 1 extstin12 holes to patch in the plates once modified. Please confine 11 is acceptable to ‘veld a hcxhcad holt front the hack side of the plate thio tflese holes. 3. Please cot -Irwin 'h).' th:c_ canopies circ: I\ installed on the \'est cicv;llion \ ill not need to he modified. Proposed new holes 1. Per my conversation with Structural Engineer - Acceptable, confirm 1 1/4" diarn. vs. previous 1 1/8" noted with subcontractor. 2. Acceptable. 3.Contirmed - no modifications required to installed plates on west elevation. 1/26/2011 Operator Region GROUND PENETRATING ADAR SYSTEMS, INC. "THE NEW WAY TO X-RAY" Main Office: 419-843-9804 Main Office Fax: 419-843-5829 Nationwide Service Available www.gp-radar.com JOB TICKET Customer: Customer Address: Job Date: Job Location: PO#: Job# Work Description CREDIT CARD INFORMATION VISA n MASTERCARDf DISCOVER fl Am/EXT] Card #: Company Name: Billing Address: Terms & Conditions City Check Number: CID#: Name on Credit Card: State Zip 1. GPRS provides Ground Penetrating Radar (GPR) services. While a good percentage of our work does deal with assisting in the detection of underground utility location. we are not a utility locating company. Ground Penetrating Radar is a Geophysical Mapping technique. GPR is a Great tool for utility locating: however, it is not without its limitations. In general, our maximum depth penetration is 3-7' deep, however, this depth is completely dependent on the composition of soils in the area being surveyed. Customer fully understands that for every foot in depth penetration with the GPR equipment, the pipe/utility must be at least 1" in diameter to be located. For example, at 4 feet in depth the pipe/utility must be 4" or larger to be detected. Some types of pipes are very difficult to locate, such as clay or concrete pipes, and empty pvc type pipes. Given these factors. GPRS CANNOT guarantee we will be able to locate ALL utilities on site. 2. Our goal is to provide you with the answers to the questions regarding what lies below the surface and where it is located. You acknowledge that you understand that our answers are based upon an interpretation of retrieved data and are what we believe lies below the surface. 3. In the event our interpretation is inaccurate, we do not accept liability for, and you agree to release us from, alleged negligence and/or damages. The decision to proceed with cutting, drilling, boring or excavation is left entirely up to the customer. Customer also fully understands that the GPR equipment cannot scan the 4" up to any wall/ceiling/corner. 4. Payment is due within 30 days of job completion. Thank you for allowing us to serve you. We look forward to working for you again. Please Print Name Here Authorizing Signature Phone: E -Mail: SUNDANCE ARCHrTECTURAL PRODUCTS, LLC SIR, FERGUSON DRIVE ORLANDO, rt roll Frt.!, 800.490.1111 www_SIMP.cogn PROJECT: CORR Intermodal Parking Garage ATTN: CONTRACTOR: ADDRESS: SUBMITTED BY: Daniel Oates Flintco, Inc 8100 Cross Park Drive Austin, TX 78754 Nick Toincykoski Estimated Cost Impact: yes Est. Schedule Impact: yes Request For Information JOBU: TXAPM1002-0002 LOCATION: Round Rock, TX PHONE: 512.891.7224 FAX: 512.891.7229 E-MAIL: DOates@flintco.com DATE SUBMITTED: January 26, 2011 Response Required Within / Days Due to conflicts with Rebar in the existing columns, modification to the (23) remaining 15" x 15" x 3/4" wall plates is required. ,,,'0 - ,.. "-. .:-., ' zs4Trm. ' Sundance Shop drawings - 4/1-9 3/5-4.7 iPROPOSEDSLtJT1O '...'_'4.L1 The engineer of record and our engineer have determined that (2) Hilti 1" HAS SS Rods, w/ 9" min. embed, anchor using HY-150 MAX will sufficiently secure the wall plate to the column. I he holes shall be centered in the column and in the wall plate, top and bottom, w/ 9" min. distance between anchors. See attached layout. ,rCost impact: $1,850.00 Impact: Additional 5 days Schedule ANSWER / RESPONSE: 4— RFI t002 1/26/2011 PAGE 1 OF 3 SUNDANCE ARCHITECTURAL PRODUCTS, LLC S3S FERGUSON DR{VE ORLANDO. FL roll Hee N 0 0 490.1317 1 www.SOAP.com PROJECT: CORR Intermodal Parking Garage ATTN: Daniel Oates CONTRACTOR: Flintco, Inc ADDRESS: 8100 Cross Park Drive Austin, TX 78754 SUBMITTED BY: Nick Tomcykoski Weir Estimated Cost Impact: Est. Schedule Impact: yes yes Request For Information JOB 1*: TXAPM1002-0002 LOCATION: Round Rock, TX PHONE: 512.891.7224 FAX: 512.891.7229 E-MAIL: DOates@flintco.com DATE SUBMITTED: January 26, 2011 Response Required Within 1 Days Assuming RFI #02 is approved will be left vacant. , there will be (4) 1"� holes in the (23) remaining 15" x 15" x 3/4" wall plates that Sundance Shop drawings - 4/1-9 3/S-4.7 Install decorative 'dummy' bolt heads, tack welded to the backside of the plate. Cost impact: $500 Impact: Additional 1 day Schedule ANSWER / RESPONSE: RFI # 002 1/26/2011 PAGE 2 OF 3 Proposed Change Order #23 City of Round Rock Intermodal Transit and Parking Facility City of Round Rock, TX Owner. The City of Round Rock Description: Added heater to Elevator Machine Room per Change Request 7 A: Material & Equipment: B: Labor 1LiNTco Constructive Solutions Sales Tax ( 0.00%) $ Subtotal A $ Labor Burden ( 44.00 %) $ Subtotal B $ C: Subcontractors - See attached quotations Mtech Comfort Systems $ 1228 68 RK Bass $ 3,058.11 Subtotal C $ 4,286.79 Subtotal A - C $ 4,286.79 D. General Contractor Mark-Up ( 10%) $ 428.68 Subtotal D $ 428.68 TOTAL: $ 4,715 F. Contract Time Extension 0 Calendar Days ❑Asbestos Allowance []Change Order Flintco, Inc. , The City of Round Rock By: Daniel Oates - Project Manager Larry Madsen - Public Works Rep 13y: 17 -Feb Date Signed Date Signed Barnes, Gromatzky, Kosarek Architects By: Arturo Arredondo Date Signed Change Request Date February 11, 2011 Reference Number Mechanical / Electrical CR #7 Project Name CoRR Intermodal Transit & Parking Garage Aged Number BGKA 0903 Mancuso Daniel Oates roe Heater for Elevator Machine Room Address Flintco, Inc. 8100 Cross Park Drive Austin, TX 78754-5249 RFP Na CO No. Cost Days APprovd Discipline Number Desaipllon tissue Dela Mech/Elect CR #7 Heater for Elevator Machine Room 2/11/2011 Reason and Justification Provide heater required to maintain minimum 50 degree temperature in the elevator machine room as required by the elevator machine room equipment manufacturer. CPR#7 Mechanical Items: Provide a 5kW heater to be mounted in the elevator machine room. Provide Markel heater model number F2F5105N or approved alternate. Heater shall be rated for 208V three phase. Provide heater with wall mounted thermostat and mounting brackets. Set thermostat to 50 degree F to energize the heater. Mount the unit per manufacturer's instructions and recommendations. Electrical Items: Provide 30 Amp 208V three phase circuit to elevator machine room 5kW heater. Circuit shall be 3412 routed in existing conduit (with spare capacity) to elevator machine room. Remove existing 20/1 breakers in P1-32, 34 and 36 and replace with a 30/3 breaker. Provide 30/3P/NF lockable disconnect switch at unit heater in elevator equipment room. cagy to Larry Madsen 1508 west 5111 Street Suite 200 Austin. Tens 78703 512.476.7133 Far 512478.2824 sped Arturo Arredondo, AIA Project Manager +I aeg ai a.Deo 2144 COMFORT SYSTEMS LICA Summary Page Project Name: CORR Intermodal Project Number: 4396 Project Change Description: CPR #7 - Unit heater addition Material & Equipment Amount A. Piping Equipment j $0.00 B. HVAC Equipment - unit heater per attached quote $550.00 C. Sheetmetal Material � $0.00 D. Piping Material f $0.00 Labor - ( cludes burden) Standard Premium E. Pipefitter / Plumber F. Duct - G.A rHelper Apprentice / Hel er P H. Start-upTechnician I. Crew Foreman Miscellaneous 0.00 _ 4.00 0.00 0.00 4.00 hours x labor rate hours x labor rate hours x labor rate hours x labor rate hours x labor rate S39.78 S39.78 521.63 541.62 541.62 559.67 559.67 532.45 $62.43 $62.43 $0.00 5159.12 $0.00 $0.00 5166.48 Standard Premium J. Project Manager K. Drafting L. Fuel Costs - 1 R/T M. Rentals N. Freight / Drayage O. O&M Manuals/ As-built drawings 1.00 0.00 18.00 hours x labor hours x labor miles x mileage rate rate rate $0.00 S58.35 539.78 $0.6.2 x $87.53 $59.67 S 1.90 55.8.35 $0. 00 511.1.1 6 $0.00 50.00 50.00 P. Miscellaneous Materials (A,B,C,D) 5550.00 x 15% 58250 Q. Warranty Reserve (A.B,C,D) 5550.00 x 6% 533.00 R. Identification and Painting 50.00 S. Testing (E,F) $0.00 x 7% 50.00 T. Storage Costs U. Extended Contract Costs V. Small Tools (E,F,H) $159.12 x 2% 53.18 W. Sales Tax $0.00 x 8.25% 50.00 Mechanical Technical Services - Direct Costs $1,063.79 Overhead Profit Mechanical 10% 5% Technical $106.38 558.51 Services - Subtotal Subcontractors 51,228.68 1) 2) 3) Subcontractor - Subtotal Overhead & Profit I 10% f 50.00 $0.00 Subcontractor - Subtotal - S0.00 - Bond Premium 0% 50.00 PROJECT CHANGE TOTAL 51 228.68 R.K. Bass Electric, Inc. 1200 E FM 2410 * PO Box 2464, Harker Heights, TX 76548 Phone: 254-698-8751 • Fax 254-698-3411 * wwwb ic.cxrn RK# 9 Customer Change Request: Project Round Rock Parking Date Submitted: 2/16/2011 Date Requested: 2/14/2011 Contractor: Flintco Description of Change: Provide power for 5KW heater for Elevator Room Material Amount 780.67 Equipment Subtotal Material and Equipment $ 780.67 Labor (includes Burden) # of hours Standard Premium Labor - Oectrician 25.19 hours x labor $ 52.10 $ 78.15 $ 1,312.24 A&soellaneous Field Supervision 1.3 hours x labor $ 58.56 $ 87.84 $ 73.75 Drafting 0 hours x labor $ 52.10 $ 78.15 Fuel Costs 0 miles x mileage rate $ 0.41 $ Fn3ight $ 780.67 x .03 O&M Manuals / As built drawings Miscellaneous Material $ 780.67 x .15 $ 117.10 Warranty Reserve $ 780.67 X .02 $ 15.61 Testing $ 1,312.24 X .07 $ 91.86 Storage Costs SmaMTools $ 1,312.24 x.02 $ 26.24 Sales Tax (Equipment Only) $ - x .0a2s Direct Costs Overhead Profit Subtotal Bond Premum Total Cost Subcontractor Overhead Profit 15% 10% 1% 15% 10% Extension of time required is ,Q days. $ 2,417.48 $ 362.62 $ 278.01 $ 3,058.11 $ 3,058.11 $ 3.058.11 This proposal is for acceptance within 10 days and is subject to escalation thereafter or subject to voidance. SUBMTTED BY: TITLE DATE: Robert Eno Supervisor / Project Manager 2/16/2011 ACCEPTED BY: TITLE: DATE RK Bass Electric Inc Arct. PR RK# 1 ESTIMATE SCHEDULE Date: 2/16/2011 QUANTIT DESCRIPTION 30 3/4 EMT 6 1/2 Flex 900 10 THHN 3 3/4 WT Conn 2 1/2 Flex Conn 1 3/4 WT Coup 5 3/4 Standoff straps 1 Bell Box with 3/4KO 1 30 Amp Disconnect 1 30A/3P breaker MATERIAL MATERIAL LABOR LABOR UNIT EXTENSION UNIT EXTENSION 0.65 19.51 0.053 1.59 0.38 2.27 0.040 0.24 0.22 198.00 0.020 18.00 4.91 14.74 0.087 0.26 0.34 0.68 0.100 0.20 0.32 0.32 0.060 0.06 1.45 7.23 0.022 0.11 4.76 4.76 0.794 0.79 209.30 209.30 2.980 2.98 323.86 323.86 0.952 0.95 Total 780.67 25.19